Gregor Jasny wrote: > 2007/6/6, Tejun Heo : >> Let's see where we're failing. > > [ 186.849280] ata_piix 0000:00:07.1: version 2.11 > [ 186.849665] scsi0 : ata_piix > [ 186.850241] scsi1 : ata_piix > [ 186.850596] ata1: PATA max UDMA/33 cmd 0x000101f0 ctl 0x000103f6 > bmdma 0x00010860 irq 14 > [ 186.851203] ata2: PATA max UDMA/33 cmd 0x00010170 ctl 0x00010376 > bmdma 0x00010868 irq 15 > [ 0.656666] Marking TSC unstable due to: possible TSC halt in C2. > [ 0.659999] Time: acpi_pm clocksource has been installed. > [ 0.659999] Switched to NOHz mode on CPU #0 > [ 0.659999] ata1: ata_bus_post_reset: EXIT3 > [ 0.709999] ata1.00: ata_hpa_resize 1: sectors = 78242976, > hpa_sectors = 78242976 > [ 0.723333] ata1.00: ATA-7: SAMSUNG MP0402H, UC100-14, max UDMA/100 > [ 0.739999] ata1.00: 78242976 sectors, multi 8: LBA48 > [ 0.763333] ata1.00: ata_hpa_resize 1: sectors = 78242976, > hpa_sectors = 78242976 > [ 0.776666] ata1.00: configured for UDMA/33 > [ 1.376666] Clocksource tsc unstable (delta = -498091579 ns) > [ 10.799998] ata2: ata_bus_post_reset: EXIT1 > [ 10.813332] ata2: SRST failed (errno=-16) > [ 20.836664] ata2: ata_bus_post_reset: EXIT1 > [ 20.849997] ata2: SRST failed (errno=-16) > [ 55.869994] ata2: ata_bus_post_reset: EXIT1 > [ 55.883327] ata2: SRST failed (errno=-16) > [ 60.903327] ata2: ata_bus_post_reset: EXIT1 > [ 60.916660] ata2: SRST failed (errno=-16) > [ 60.929993] ata2: reset failed, giving up > [ 60.946660] scsi 0:0:0:0: Direct-Access ATA SAMSUNG > MP0402H UC10 PQ: 0 ANSI: 5 Ah.. okay. Now I see what's going on. Jeff, this is another device which doesn't set nsect and lbal to 1 after reset. Gregor, please try the attached patch. Thanks. -- tejun