* [PATCH] iio: light sensor: Improve granularity of tsl2583 lux values.
@ 2011-12-02 22:12 Bryan Freed
  0 siblings, 0 replies; only message in thread
From: Bryan Freed @ 2011-12-02 22:12 UTC (permalink / raw)
  To: jbrenner; +Cc: linux-iio, jic23, gregkh, linux-kernel, Bryan Freed

When illuminance0_calibbias gets 4000 (for a 4x multiplier), we see lux
granularity of 4.  Reversing the order of the right shift and multiplication
retains the precision of the unadjusted lux value.

Signed-off-by: Bryan Freed <bfreed@chromium.org>
---
 drivers/staging/iio/light/tsl2583.c |   17 ++++++++++++++---
 1 files changed, 14 insertions(+), 3 deletions(-)

diff --git a/drivers/staging/iio/light/tsl2583.c b/drivers/staging/iio/light/tsl2583.c
index 80f77cf..186a3ec 100644
--- a/drivers/staging/iio/light/tsl2583.c
+++ b/drivers/staging/iio/light/tsl2583.c
@@ -194,6 +194,7 @@ static int taos_get_lux(struct iio_dev *indio_dev)
 {
 	u16 ch0, ch1; /* separated ch0/ch1 data from device */
 	u32 lux; /* raw lux calculated from device data */
+	u64 lux64;
 	u32 ratio;
 	u8 buf[5];
 	struct taos_lux *p;
@@ -297,9 +298,19 @@ static int taos_get_lux(struct iio_dev *indio_dev)
 		lux = (lux + (chip->als_time_scale >> 1)) /
 			chip->als_time_scale;
 
-	/* adjust for active gain scale */
-	lux >>= 13; /* tables have factor of 8192 builtin for accuracy */
-	lux = (lux * chip->taos_settings.als_gain_trim + 500) / 1000;
+	/* Adjust for active gain scale.
+	 * The taos_device_lux tables above have a factor of 8192 built in,
+	 * so we need to shift right.
+	 * User-specified gain provides a multiplier.
+	 * Apply user-specified gain before shifting right to retain precision.
+	 * Use 64 bits to avoid overflow on multiplication.
+	 * Then go back to 32 bits before division to avoid using div_u64().
+	 */
+	lux64 = lux;
+	lux64 = lux64 * chip->taos_settings.als_gain_trim + 500;
+	lux64 >>= 13;
+	lux = lux64;
+	lux /= 1000;
 	if (lux > TSL258X_LUX_CALC_OVER_FLOW) { /* check for overflow */
 return_max:
 		lux = TSL258X_LUX_CALC_OVER_FLOW;
-- 
1.7.3.1

^ permalink raw reply related	[flat|nested] only message in thread

only message in thread, other threads:[~2011-12-02 22:12 UTC | newest]

Thread overview: (only message) (download: mbox.gz follow: Atom feed
-- links below jump to the message on this page --
2011-12-02 22:12 [PATCH] iio: light sensor: Improve granularity of tsl2583 lux values Bryan Freed

This is a public inbox, see mirroring instructions
for how to clone and mirror all data and code used for this inbox;
as well as URLs for NNTP newsgroup(s).