From mboxrd@z Thu Jan 1 00:00:00 1970 Return-Path: Received: from mga02.intel.com ([134.134.136.20]:44287 "EHLO mga02.intel.com" rhost-flags-OK-OK-OK-OK) by vger.kernel.org with ESMTP id S1751711AbaE0PXp (ORCPT ); Tue, 27 May 2014 11:23:45 -0400 Message-ID: <5384AEFE.2010804@linux.intel.com> Date: Tue, 27 May 2014 08:27:58 -0700 From: Srinivas Pandruvada MIME-Version: 1.0 To: Reyad Attiyat CC: linux-kernel@vger.kernel.org, linux-iio@vger.kernel.org, jic23@kernel.org Subject: Re: [PATCH] IIO: Added iio magn_north ABI documentation References: <538076CA.6050809@kernel.org> <1401160821-5006-1-git-send-email-reyad.attiyat@gmail.com> <1401160821-5006-2-git-send-email-reyad.attiyat@gmail.com> In-Reply-To: <1401160821-5006-2-git-send-email-reyad.attiyat@gmail.com> Content-Type: text/plain; charset=ISO-8859-1; format=flowed Sender: linux-iio-owner@vger.kernel.org List-Id: linux-iio@vger.kernel.org On 05/26/2014 08:20 PM, Reyad Attiyat wrote: > Added documentation for HID magnometer true/magnetic north sensor. > --- > Documentation/ABI/testing/sysfs-bus-iio | 76 +++++++++++++++++++++++++++++++++ > 1 file changed, 76 insertions(+) > > diff --git a/Documentation/ABI/testing/sysfs-bus-iio b/Documentation/ABI/testing/sysfs-bus-iio > index 6e02c50..3305fe8 100644 > --- a/Documentation/ABI/testing/sysfs-bus-iio > +++ b/Documentation/ABI/testing/sysfs-bus-iio > @@ -165,6 +165,10 @@ Description: > What: /sys/bus/iio/devices/iio:deviceX/in_magn_x_raw > What: /sys/bus/iio/devices/iio:deviceX/in_magn_y_raw > What: /sys/bus/iio/devices/iio:deviceX/in_magn_z_raw > +What: /sys/bus/iio/devices/iio:deviceX/in_magn_north_magnetic_raw > +What: /sys/bus/iio/devices/iio:deviceX/in_magn_north_true_raw > +What: /sys/bus/iio/devices/iio:deviceX/in_magn_north_magnetic_tilt_compensated_raw > +What: /sys/bus/iio/devices/iio:deviceX/in_magn_north_true_tilt_compensated_raw These names are very long. May be we remove work "magnetic" as there attributes only apply to magnetometer. > KernelVersion: 2.6.35 > Contact: linux-iio@vger.kernel.org > Description: > @@ -249,6 +253,10 @@ What: /sys/bus/iio/devices/iio:deviceX/in_magn_scale > What: /sys/bus/iio/devices/iio:deviceX/in_magn_x_scale > What: /sys/bus/iio/devices/iio:deviceX/in_magn_y_scale > What: /sys/bus/iio/devices/iio:deviceX/in_magn_z_scale > +What: /sys/bus/iio/devices/iio:deviceX/in_magn_north_magnetic_scale > +What: /sys/bus/iio/devices/iio:deviceX/in_magn_north_true_scale > +What: /sys/bus/iio/devices/iio:deviceX/in_magn_north_magnetic_tilt_compensated_scale > +What: /sys/bus/iio/devices/iio:deviceX/in_magn_north_true_tilt_compensated_scale > What: /sys/bus/iio/devices/iio:deviceX/in_pressureY_scale > What: /sys/bus/iio/devices/iio:deviceX/in_pressure_scale > KernelVersion: 2.6.35 > @@ -436,6 +444,14 @@ What: /sys/.../iio:deviceX/events/in_magn_y_thresh_rising_en > What: /sys/.../iio:deviceX/events/in_magn_y_thresh_falling_en > What: /sys/.../iio:deviceX/events/in_magn_z_thresh_rising_en > What: /sys/.../iio:deviceX/events/in_magn_z_thresh_falling_en > +What: /sys/.../iio:deviceX/events/in_magn_north_magnetic_thresh_rising_en > +What: /sys/.../iio:deviceX/events/in_magn_north_magnetic_thresh_falling_en > +What: /sys/.../iio:deviceX/events/in_magn_north_true_thresh_rising_en > +What: /sys/.../iio:deviceX/events/in_magn_north_true_thresh_falling_en > +What: /sys/.../iio:deviceX/events/in_magn_north_magnetic_tilt_compensated_thresh_rising_en > +What: /sys/.../iio:deviceX/events/in_magn_north_magnetic_tilt_compensated_thresh_falling_en > +What: /sys/.../iio:deviceX/events/in_magn_north_true_tilt_compensated_thresh_rising_en > +What: /sys/.../iio:deviceX/events/in_magn_north_true_tilt_compensated_thresh_falling_en > What: /sys/.../iio:deviceX/events/in_voltageY_supply_thresh_rising_en > What: /sys/.../iio:deviceX/events/in_voltageY_supply_thresh_falling_en > What: /sys/.../iio:deviceX/events/in_voltageY_thresh_rising_en > @@ -481,6 +497,14 @@ What: /sys/.../iio:deviceX/events/in_magn_y_roc_rising_en > What: /sys/.../iio:deviceX/events/in_magn_y_roc_falling_en > What: /sys/.../iio:deviceX/events/in_magn_z_roc_rising_en > What: /sys/.../iio:deviceX/events/in_magn_z_roc_falling_en > +What: /sys/.../iio:deviceX/events/in_magn_north_magnetic_roc_rising_en > +What: /sys/.../iio:deviceX/events/in_magn_north_magnetic_roc_falling_en > +What: /sys/.../iio:deviceX/events/in_magn_north_true_roc_rising_en > +What: /sys/.../iio:deviceX/events/in_magn_north_true_roc_falling_en > +What: /sys/.../iio:deviceX/events/in_magn_north_magnetic_tilt_compensated_roc_rising_en > +What: /sys/.../iio:deviceX/events/in_magn_north_magnetic_tilt_compensated_roc_falling_en > +What: /sys/.../iio:deviceX/events/in_magn_north_true_tilt_compensated_roc_rising_en > +What: /sys/.../iio:deviceX/events/in_magn_north_true_tilt_compensated_roc_falling_en Same as above. Names are very long. Thanks, Srinivas > What: /sys/.../iio:deviceX/events/in_voltageY_supply_roc_rising_en > What: /sys/.../iio:deviceX/events/in_voltageY_supply_roc_falling_en > What: /sys/.../iio:deviceX/events/in_voltageY_roc_rising_en > @@ -527,6 +551,14 @@ What: /sys/.../events/in_magn_y_raw_thresh_rising_value > What: /sys/.../events/in_magn_y_raw_thresh_falling_value > What: /sys/.../events/in_magn_z_raw_thresh_rising_value > What: /sys/.../events/in_magn_z_raw_thresh_falling_value > +What: /sys/.../events/in_magn_north_magnetic_raw_thresh_rising_value > +What: /sys/.../events/in_magn_north_magnetic_raw_thresh_falling_value > +What: /sys/.../events/in_magn_north_true_raw_thresh_rising_value > +What: /sys/.../events/in_magn_north_true_raw_thresh_falling_value > +What: /sys/.../events/in_magn_north_magnetic_tilt_compensated_raw_thresh_rising_value > +What: /sys/.../events/in_magn_north_magnetic_tilt_compensated_raw_thresh_falling_value > +What: /sys/.../events/in_magn_north_true_tilt_compensated_raw_thresh_rising_value > +What: /sys/.../events/in_magn_north_true_tilt_compensated_raw_thresh_falling_value > What: /sys/.../events/in_voltageY_supply_raw_thresh_rising_value > What: /sys/.../events/in_voltageY_supply_raw_thresh_falling_value > What: /sys/.../events/in_voltageY_raw_thresh_rising_value > @@ -577,6 +609,18 @@ What: /sys/.../events/in_magn_y_thresh_either_hysteresis > What: /sys/.../events/in_magn_z_thresh_rising_hysteresis > What: /sys/.../events/in_magn_z_thresh_falling_hysteresis > What: /sys/.../events/in_magn_z_thresh_either_hysteresis > +What: /sys/.../events/in_magn_north_magnetic_thresh_rising_hysteresis > +What: /sys/.../events/in_magn_north_magnetic_thresh_falling_hysteresis > +What: /sys/.../events/in_magn_north_magnetic_thresh_either_hysteresis > +What: /sys/.../events/in_magn_north_true_thresh_rising_hysteresis > +What: /sys/.../events/in_magn_north_true_thresh_falling_hysteresis > +What: /sys/.../events/in_magn_north_true_thresh_either_hysteresis > +What: /sys/.../events/in_magn_north_magnetic_tilt_compensated_thresh_rising_hysteresis > +What: /sys/.../events/in_magn_north_magnetic_tilt_compensated_thresh_falling_hysteresis > +What: /sys/.../events/in_magn_north_magnetic_tilt_compensated_thresh_either_hysteresis > +What: /sys/.../events/in_magn_north_true_tilt_compensated_thresh_rising_hysteresis > +What: /sys/.../events/in_magn_north_true_tilt_compensated_thresh_falling_hysteresis > +What: /sys/.../events/in_magn_north_true_tilt_compensated_thresh_either_hysteresis > What: /sys/.../events/in_voltageY_thresh_rising_hysteresis > What: /sys/.../events/in_voltageY_thresh_falling_hysteresis > What: /sys/.../events/in_voltageY_thresh_either_hysteresis > @@ -624,6 +668,14 @@ What: /sys/.../events/in_magn_y_raw_roc_rising_value > What: /sys/.../events/in_magn_y_raw_roc_falling_value > What: /sys/.../events/in_magn_z_raw_roc_rising_value > What: /sys/.../events/in_magn_z_raw_roc_falling_value > +What: /sys/.../events/in_magn_north_magnetic_raw_roc_rising_value > +What: /sys/.../events/in_magn_north_magnetic_raw_roc_falling_value > +What: /sys/.../events/in_magn_north_true_raw_roc_rising_value > +What: /sys/.../events/in_magn_north_true_raw_roc_falling_value > +What: /sys/.../events/in_magn_north_magnetic_tilt_compensated_raw_roc_rising_value > +What: /sys/.../events/in_magn_north_magnetic_tilt_compensated_raw_roc_falling_value > +What: /sys/.../events/in_magn_north_true_tilt_compensated_raw_roc_rising_value > +What: /sys/.../events/in_magn_north_true_tilt_compensated_raw_roc_falling_value > What: /sys/.../events/in_voltageY_supply_raw_roc_rising_value > What: /sys/.../events/in_voltageY_supply_raw_roc_falling_value > What: /sys/.../events/in_voltageY_raw_roc_rising_value > @@ -679,6 +731,22 @@ What: /sys/.../events/in_magn_z_thresh_rising_period > What: /sys/.../events/in_magn_z_thresh_falling_period > What: /sys/.../events/in_magn_z_roc_rising_period > What: /sys/.../events/in_magn_z_roc_falling_period > +What: /sys/.../events/in_magn_north_magnetic_thresh_rising_period > +What: /sys/.../events/in_magn_north_magnetic_thresh_falling_period > +What: /sys/.../events/in_magn_north_magnetic_roc_rising_period > +What: /sys/.../events/in_magn_north_magnetic_roc_falling_period > +What: /sys/.../events/in_magn_north_true_thresh_rising_period > +What: /sys/.../events/in_magn_north_true_thresh_falling_period > +What: /sys/.../events/in_magn_north_true_roc_rising_period > +What: /sys/.../events/in_magn_north_true_roc_falling_period > +What: /sys/.../events/in_magn_north_magnetic_tilt_compensated_thresh_rising_period > +What: /sys/.../events/in_magn_north_magnetic_tilt_compensated_thresh_falling_period > +What: /sys/.../events/in_magn_north_magnetic_tilt_compensated_roc_rising_period > +What: /sys/.../events/in_magn_north_magnetic_tilt_compensated_roc_falling_period > +What: /sys/.../events/in_magn_north_true_tilt_compensated_thresh_rising_period > +What: /sys/.../events/in_magn_north_true_tilt_compensated_thresh_falling_period > +What: /sys/.../events/in_magn_north_true_tilt_compensated_roc_rising_period > +What: /sys/.../events/in_magn_north_true_tilt_compensated_roc_falling_period > What: /sys/.../events/in_voltageY_supply_thresh_rising_period > What: /sys/.../events/in_voltageY_supply_thresh_falling_period > What: /sys/.../events/in_voltageY_supply_roc_rising_period > @@ -776,6 +844,10 @@ What: /sys/.../iio:deviceX/scan_elements/in_anglvel_z_en > What: /sys/.../iio:deviceX/scan_elements/in_magn_x_en > What: /sys/.../iio:deviceX/scan_elements/in_magn_y_en > What: /sys/.../iio:deviceX/scan_elements/in_magn_z_en > +What: /sys/.../iio:deviceX/scan_elements/in_magn_north_magnetic_en > +What: /sys/.../iio:deviceX/scan_elements/in_magn_north_true_en > +What: /sys/.../iio:deviceX/scan_elements/in_magn_north_magnetic_tilt_compensated_en > +What: /sys/.../iio:deviceX/scan_elements/in_magn_north_true_tilt_compensated_en > What: /sys/.../iio:deviceX/scan_elements/in_timestamp_en > What: /sys/.../iio:deviceX/scan_elements/in_voltageY_supply_en > What: /sys/.../iio:deviceX/scan_elements/in_voltageY_en > @@ -840,6 +912,10 @@ What: /sys/.../iio:deviceX/scan_elements/in_anglvel_z_index > What: /sys/.../iio:deviceX/scan_elements/in_magn_x_index > What: /sys/.../iio:deviceX/scan_elements/in_magn_y_index > What: /sys/.../iio:deviceX/scan_elements/in_magn_z_index > +What: /sys/.../iio:deviceX/scan_elements/in_magn_north_magnetic_index > +What: /sys/.../iio:deviceX/scan_elements/in_magn_north_true_index > +What: /sys/.../iio:deviceX/scan_elements/in_magn_north_magnetic_tilt_compensated_index > +What: /sys/.../iio:deviceX/scan_elements/in_magn_north_true_tilt_compensated_index > What: /sys/.../iio:deviceX/scan_elements/in_incli_x_index > What: /sys/.../iio:deviceX/scan_elements/in_incli_y_index > What: /sys/.../iio:deviceX/scan_elements/in_timestamp_index