From mboxrd@z Thu Jan 1 00:00:00 1970 From: Mark Brown Subject: Re: [PATCH] twl6030: regulator: Remove vsel tables and use formula for calculation Date: Fri, 23 Apr 2010 12:18:43 +0100 Message-ID: <20100423111843.GB27232@rakim.wolfsonmicro.main> References: <1271926112-7700-1-git-send-email-rnayak@ti.com> Mime-Version: 1.0 Content-Type: text/plain; charset=us-ascii Return-path: Received: from opensource.wolfsonmicro.com ([80.75.67.52]:40205 "EHLO opensource2.wolfsonmicro.com" rhost-flags-OK-OK-OK-FAIL) by vger.kernel.org with ESMTP id S1754848Ab0DWLSp (ORCPT ); Fri, 23 Apr 2010 07:18:45 -0400 Content-Disposition: inline In-Reply-To: <1271926112-7700-1-git-send-email-rnayak@ti.com> Sender: linux-omap-owner@vger.kernel.org List-Id: linux-omap@vger.kernel.org To: Rajendra Nayak Cc: linux-omap@vger.kernel.org, Liam Girdwood , Samuel Ortiz On Thu, Apr 22, 2010 at 02:18:32PM +0530, Rajendra Nayak wrote: > All twl6030 regulators can be programmed from 1.0v to 3.3v > with 100mV steps. > The below formula can be used to calculate the vsel values > to be programmed in the VREG_VOLTAGE registers. Acked-by: Mark Brown