From mboxrd@z Thu Jan 1 00:00:00 1970 Return-Path: Received: from colo.lackof.org (colo.lackof.org [198.49.126.79]) by dsl2.external.hp.com (Postfix) with ESMTP id 7DE2B484B for ; Sun, 8 Feb 2004 20:56:24 -0700 (MST) Date: Sun, 8 Feb 2004 20:56:21 -0700 From: Grant Grundler To: willy@debian.org Message-ID: <20040209035621.GD21692@colo.lackof.org> Mime-Version: 1.0 Content-Type: text/plain; charset=us-ascii Cc: parisc-linux@lists.parisc-linux.org Subject: [parisc-linux] 2.6.3-rc1 sym2 hangs on a500-65 List-Id: parisc-linux developers list List-Unsubscribe: , List-Archive: List-Post: List-Help: List-Subscribe: , Matthew, a500 (ion) hangs with /boot/vmlinux-2.6.3-rc1-pa2. Having problems with bus reset code path. I'll collect TOC info and make that available. thanks, grant Firmware Version 42.19 Duplex Console IO Dependent Code (IODC) revision 1 ------------------------------------------------------------------------------ (c) Copyright 1995-2001, Hewlett-Packard Company, All rights reserved ------------------------------------------------------------------------------ Processor Speed State CoProcessor State Cache Size Number State Inst Data --------- -------- --------------------- ----------------- ------------ 0 650 MHz Active Functional 750 KB 1.5 MB Central Bus Speed (in MHz) : 120 Available Memory : 1048576 KB Good Memory Required : 25820 KB Primary boot path: 0/0/2/1.15 Alternate boot path: 0/0/1/1.15 Console path: 0/0/4/1.643 Keyboard path: 0/0/4/0.0 ---- Main Menu --------------------------------------------------------------- Command Description ------- ----------- BOot [PRI|ALT|] Boot from specified path PAth [PRI|ALT] [] Display or modify a path SEArch [DIsplay|IPL] [] Search for boot devices COnfiguration menu Displays or sets boot values INformation menu Displays hardware information SERvice menu Displays service commands DIsplay Redisplay the current menu HElp [|] Display help for menu or command RESET Restart the system ---- Main Menu: Enter command or menu > bo Interact with IPL (Y, N, or Cancel)?> y Booting... Boot IO Dependent Code (IODC) revision 1 HARD Booted. palo ipl 1.2 root@b2000 Tue Jan 14 13:13:07 MST 2003 Partition Start(MB) End(MB) Id Type 1 1 512 82 swap 2 513 532 f0 Palo 3 533 2048 83 ext2 4 2049 8682 83 ext2 PALO(F0) partition contains: 0/vmlinux64 5382306 bytes @ 0x20040000 Information: No console specified on kernel command line. This is normal. PALO will choose the console currently used by firmware (serial).Current command line: 3/boot/vmlinux initrd=3/boot/initrd.img root=/dev/sdb3 HOME=/ console=ttyS0 TERM=vt102 0: 3/boot/vmlinux 1: initrd=3/boot/initrd.img 2: root=/dev/sdb3 3: HOME=/ 4: console=ttyS0 5: TERM=vt102 Edit which field? (or 'b' to boot with this command line)? 0 3/boot/vmlinux-2.6.3-rc1-pa2 Current command line: 3/boot/vmlinux-2.6.3-rc1-pa2 initrd=3/boot/initrd.img root=/dev/sdb3 HOME=/ console=ttyS0 TERM=vt102 0: 3/boot/vmlinux-2.6.3-rc1-pa2 1: initrd=3/boot/initrd.img 2: root=/dev/sdb3 3: HOME=/ 4: console=ttyS0 5: TERM=vt102 Edit which field? (or 'b' to boot with this command line)? b Command line for kernel: ' root=/dev/sdb3 HOME=/ console=ttyS0 TERM=vt102 palo_kernel=3/boot/vmlinux-2.6.3-rc1-pa2' Selected kernel: /boot/vmlinux-2.6.3-rc1-pa2 from partition 3 Selected ramdisk: /boot/initrd.img from partition 3 ELF64 executable Entry 00100000 first 00100000 n 2 Segment 0 load 00100000 size 3581040 mediaptr 0x1000 Segment 1 load 0046c000 size 237701 mediaptr 0x36c000 Loading ramdisk 3256320 bytes @ 3fcd2000... Branching to kernel entry point 0x00100000. If this is the last message you see, you may need to switch your console. This is a common symptom -- search the FAQ and mailing list at parisc-linux.org Linux version 2.6.3-rc1-pa2 (grundler@gsyprf11.external.hp.com) (gcc version 3.0.4) #3 Sun Feb 8 15:40:17 PST 2004 FP[0] enabled: Rev 1 Model 19 The 64-bit Kernel has started... Determining PDC firmware type: 64 bit PAT. model 00005e20 00000491 00000000 00000001 6df6c82e 100000f0 00000008 000000b2 000000b2 vers 00000203 CPUID vers 19 rev 8 (0x00000268) capabilities 0x5 model 9000/800/A500-6X Total Memory: 1024 Mb initrd: 4fcd2000-4ffed000 initrd: reserving 3fcd2000-3ffed000 (mem_max 40000000) On node 0 totalpages: 262144 DMA zone: 262144 pages, LIFO batch:16 Normal zone: 0 pages, LIFO batch:1 HighMem zone: 0 pages, LIFO batch:1 Built 1 zonelists Kernel command line: root=/dev/sdb3 HOME=/ console=ttyS0 TERM=vt102 palo_kernel=3/boot/vmlinux-2.6.3-rc1-pa2 PID hash table entries: 16 (order 4: 256 bytes) Console: colour dummy device 160x64 Memory: 1018752k available Calibrating delay loop... 1294.33 BogoMIPS Dentry cache hash table entries: 131072 (order: 8, 1048576 bytes) Inode-cache hash table entries: 65536 (order: 7, 524288 bytes) Mount-cache hash table entries: 256 (order: 0, 4096 bytes) checking if image is initramfs...it isn't (ungzip failed); looks like an initrd POSIX conformance testing by UNIFIX NET: Registered protocol family 16 Searching for devices... Found devices: 1. Crescendo 650 W2 at 0xfffffffffffa0000 [160] { 0, 0x0, 0x5e2, 0x00004 } 2. Astro BC Runway Port at 0xfffffffffed00000 [0] { 12, 0x0, 0x582, 0x0000b } 3. Elroy PCI Bridge at 0xfffffffffed30000 [0/0] { 13, 0x0, 0x782, 0x0000a } 4. Elroy PCI Bridge at 0xfffffffffed34000 [0/2] { 13, 0x0, 0x782, 0x0000a } 5. Elroy PCI Bridge at 0xfffffffffed38000 [0/4] { 13, 0x0, 0x782, 0x0000a } 6. Elroy PCI Bridge at 0xfffffffffed3c000 [0/6] { 13, 0x0, 0x782, 0x0000a } 7. Memory at 0xfffffffffed08000 [8] { 1, 0x0, 0x09b, 0x00009 } CPU(s): 1 x PA8700 (PCX-W2) at 650.000000 MHz SBA found Astro 2.1 at 0xfffffffffed00000 lba version TR4.0 (0x5) found at 0xfffffffffed30000 iosapic: no IRTE for 0000:00:04.0 (IRQ not connected?) lba version TR4.0 (0x5) found at 0xfffffffffed34000 lba version TR4.0 (0x5) found at 0xfffffffffed38000 lba version TR4.0 (0x5) found at 0xfffffffffed3c000 SCSI subsystem initialized Performance monitoring counters enabled for Crescendo 650 W2 ikconfig 0.7 with /proc/config* Initializing Cryptographic API Soft power switch support not available. pty: 256 Unix98 ptys configured Generic RTC Driver v1.07 Serial: 8250/16550 driver $Revision: 1.90 $ 17 ports, IRQ sharing enabled ttyS0 at MMIO 0xfffffffff8000000 (irq = 132) is a 16550A ttyS1 at MMIO 0xfffffffff8000008 (irq = 132) is a 16450 ttyS2 at MMIO 0xfffffffff8000010 (irq = 132) is a 16550A ttyS3 at MMIO 0xfffffffff8000030 (irq = 132) is a 16550A ttyS4 at MMIO 0xfffffffff8000038 (irq = 132) is a 16550A RAMDISK driver initialized: 16 RAM disks of 6144K size 1024 blocksize loop: loaded (max 8 devices) Linux Tulip driver version 1.1.13-NAPI (May 11, 2002) tulip0: no phy info, aborting mtable build tulip0: MII transceiver #1 config 1000 status 782d advertising 0061. eth0: Digital DS21143 Tulip rev 65 at 0xfffffffff8006000, 00:30:6E:48:F6:40, IRQ 128. sym0: <896> rev 0x7 at pci 0000:00:01.0 irq 129 sym0: No NVRAM, ID 7, Fast-40, LVD, parity checking sym0: SCSI BUS has been reset. scsi0 : sym-2.1.18i Using anticipatory io scheduler sym0:0:0: ABORT operation started. sym0:0:0: ABORT operation complete. sym0:0:0: DEVICE RESET operation started. sym0:0:0: DEVICE RESET operation failed. sym0:0:0: BUS RESET operation started. sym0:0:0: BUS RESET operation failed. sym0:0:0: HOST RESET operation started. sym0:0:0: HOST RESET operation failed. scsi: Device offlined - not ready after error recovery: host 0 channel 0 id 0 lun 0 sym1: <896> rev 0x7 at pci 0000:00:01.1 irq 130 sym1: No NVRAM, ID 7, Fast-40, SE, parity checking sym1: SCSI BUS has been reset. sym1: SCSI BUS mode change from SE to SE. sym1: SCSI BUS has been reset. scsi1 : sym-2.1.18i Vendor: SEAGATE Model: ST39102LC Rev: HP03 Type: Direct-Access ANSI SCSI revision: 02 sym1:15:0: tagged command queuing enabled, command queue depth 16. sym2: <875> rev 0x37 at pci 0000:00:02.0 irq 130 sym2: No NVRAM, ID 7, Fast-20, SE, parity checking sym2: SCSI BUS has been reset. scsi2 : sym-2.1.18i sym3: <875> rev 0x37 at pci 0000:00:02.1 irq 131 sym3: No NVRAM, ID 7, Fast-20, SE, parity checking sym3: SCSI BUS has been reset. scsi3 : sym-2.1.18i Vendor: SEAGATE Model: ST39102LC Rev: 7C03 Type: Direct-Access ANSI SCSI revision: 02 sym3:15:0: tagged command queuing enabled, command queue depth 16. sym4: <1010-66> rev 0x1 at pci 0000:30:02.0 irq 322 sym4: No NVRAM, ID 7, Fast-80, LVD, parity checking sym4: SCSI BUS has been reset. scsi4 : sym-2.1.18i Vendor: HP Model: D5989C Rev: 1.03 Type: Processor ANSI SCSI revision: 02 Vendor: HP 18.2G Model: ST318452LC Rev: HP05 Type: Direct-Access ANSI SCSI revision: 02 sym4:10:0: tagged command queuing enabled, command queue depth 16. Vendor: HP Model: 18.2GB C 80-F612 Rev: Type: Direct-Access ANSI SCSI revision: 02 sym4:11:0: tagged command queuing enabled, command queue depth 16. Vendor: HP 18.2G Model: ST318452LC Rev: HP05 Type: Direct-Access ANSI SCSI revision: 02 sym4:12:0: tagged command queuing enabled, command queue depth 16. Vendor: HP Model: 9.10GB C 80-BX01 Rev: BX01 Type: Direct-Access ANSI SCSI revision: 02 sym4:13:0: tagged command queuing enabled, command queue depth 16. Vendor: HP Model: 9.10GB C 80-BX01 Rev: BX01 Type: Direct-Access ANSI SCSI revision: 02 sym4:14:0: tagged command queuing enabled, command queue depth 16. Vendor: FUJITSU Model: MAJ3091MC Rev: 0111 Type: Direct-Access ANSI SCSI revision: 04 sym4:15:0: tagged command queuing enabled, command queue depth 16. sym4:15: FAST-80 WIDE SCSI 160.0 MB/s DT (12.5 ns, offset 31) sym5: <1010-66> rev 0x1 at pci 0000:30:02.1 irq 323 sym5: No NVRAM, ID 7, Fast-80, LVD, parity checking sym5: SCSI BUS has been reset. scsi5 : sym-2.1.18i Vendor: HP Model: 18.2GB C 80-H008 Rev: H008 Type: Direct-Access ANSI SCSI revision: 02 sym5:0:0: tagged command queuing enabled, command queue depth 16. Vendor: HP Model: 18.2GB C 80-H008 Rev: H008 Type: Direct-Access ANSI SCSI revision: 02 sym5:1:0: tagged command queuing enabled, command queue depth 16. Vendor: HP 18.2G Model: ST318452LC Rev: HP05 Type: Direct-Access ANSI SCSI revision: 02 sym5:2:0: tagged command queuing enabled, command queue depth 16. sym5:3:0: ABORT operation started. sym5:3:0: ABORT operation timed-out. sym5:3:0: DEVICE RESET operation started. sym5:3:0: DEVICE RESET operation timed-out. sym5:3:0: BUS RESET operation started. sym5: SCSI BUS reset detected. sym5: SCSI BUS has been reset. sym5:3:0: BUS RESET operation complete. sym5:3:0: ABORT operation started. sym5:3:0: ABORT operation timed-out. sym5:3:0: HOST RESET operation started. sym5: SCSI BUS has been reset.