From: Nirmal Patel <nirmal.patel@linux.intel.com>
To: Bjorn Helgaas <helgaas@kernel.org>
Cc: linux-pci@vger.kernel.org, samruddh.dhope@intel.com
Subject: Re: [PATCH v2] PCI: vmd: Enable Hotplug based on BIOS setting on VMD rootports
Date: Thu, 14 Dec 2023 15:22:21 -0700 [thread overview]
Message-ID: <24a4e9c73f6447f5bb67906c57520514dfa77389.camel@linux.intel.com> (raw)
In-Reply-To: <20231214192325.GA1095340@bhelgaas>
On Thu, 2023-12-14 at 13:23 -0600, Bjorn Helgaas wrote:
> On Wed, Dec 13, 2023 at 06:07:02PM -0700, Nirmal Patel wrote:
> > On Tue, 2023-12-12 at 15:13 -0600, Bjorn Helgaas wrote:
> > > On Mon, Dec 11, 2023 at 04:05:25PM -0700, Nirmal Patel wrote:
> > > > On Tue, 2023-12-05 at 18:27 -0600, Bjorn Helgaas wrote:
> > > > > On Tue, Dec 05, 2023 at 03:20:27PM -0700, Nirmal Patel wrote:
> > > > > ...
> > > > > > Currently Hotplug is controlled by _OSC in both host and
> > > > > > Guest.
> > > > > > In case of guest, it seems guest BIOS hasn't implemented
> > > > > > _OSC
> > > > > > since all the flags are set to 0 which is not the case in
> > > > > > host.
> > > > >
> > > > > I think you want pciehp to work on the VMD Root Ports in the
> > > > > Guest, no matter what, on the assumption that any _OSC that
> > > > > applies to host bridge A does not apply to the host bridge
> > > > > created
> > > > > by the vmd driver.
> > > > >
> > > > > If so, we should just revert 04b12ef163d1 ("PCI: vmd: Honor
> > > > > ACPI
> > > > > _OSC on PCIe features"). Since host bridge B was not
> > > > > enumerated
> > > > > via ACPI, the OS owns all those features under B by default,
> > > > > so
> > > > > reverting 04b12ef163d1 would leave that state.
> > > > >
> > > > > Obviously we'd have to first figure out another solution for
> > > > > the
> > > > > AER message flood that 04b12ef163d1 resolved.
> > > >
> > > > If we revert 04b12ef163d1, then VMD driver will still enable
> > > > AER
> > > > blindly which is a bug. So we need to find a way to make VMD
> > > > driver
> > > > aware of AER platform setting and use that information to
> > > > enable or
> > > > disable AER for its child devices.
> > > >
> > > > There is a setting in BIOS that allows us to enable OS native
> > > > AER
> > > > support on the platform. This setting is located in EDK Menu ->
> > > > Platform configuration -> system event log -> IIO error
> > > > enabling ->
> > > > OS native AER support.
> > > >
> > > > This setting is assigned to VMD bridge by
> > > > vmd_copy_host_bridge_flags in patch 04b12ef163d1. Without the
> > > > patch 04b12ef163d1, VMD driver will enable AER even if platform
> > > > has disabled OS native AER support as mentioned earlier. This
> > > > will result in an AER flood mentioned in 04b12ef163d1 since
> > > > there is no AER handlers.
>
> I missed this before. What does "there are no AER handlers"
> mean? Do
> you mean there are no *firmware* AER handlers?
Sorry for confusing wordings. Your understanding is correct. The patch
04b12ef163d1 is used to disable AER on vmd and avoid the AER flooding
by applying _OSC settings since vmd driver doesn't give a choice to
toggle AER, DPC, LTR, etc.
>
> The dmesg log at https://bugzilla.kernel.org/attachment.cgi?id=299571
> (from https://bugzilla.kernel.org/show_bug.cgi?id=215027, the bug
> fixed by 04b12ef163d1), shows this:
>
> acpi PNP0A08:00: _OSC: OS supports [ExtendedConfig ASPM ClockPM
> Segments MSI HPX-Type3]
> acpi PNP0A08:00: _OSC: platform does not support [AER]
> acpi PNP0A08:00: _OSC: OS now controls [PCIeHotplug SHPCHotplug PME
> PCIeCapability LTR]
>
> so the firmware did not grant AER control to the OS (I think
> "platform
> does not support" is a confusing description).
>
> Prior to 04b12ef163d1, Linux applied _OSC above the VMD bridge but
> not
> below it, so Linux had native control below VMD and it did handle AER
> interrupts from the 10000:e0:06.0 Root Port below VMD:
>
> vmd 0000:00:0e.0: PCI host bridge to bus 10000:e0
> pcieport 10000:e0:06.0: AER: Corrected error received:
> 10000:e1:00.0
>
> After 04b12ef163d1, Linux applied _OSC below the VMD bridge as well,
> so it did not enable or handle any AER interrupts. I suspect the
> platform didn't handle AER interrupts below VMD either, so those
> errors were probably just ignored.
>
> > > > If VMD is aware of OS native AER support setting, then we will
> > > > not
> > > > see AER flooding issue.
> > > >
> > > > Do you have any suggestion on how to make VMD driver aware of
> > > > AER
> > > > setting and keep it in sync with platform setting.
> > >
> > > Well, this is the whole problem. IIUC, you're saying we should
> > > use
> > > _OSC to negotiate for AER control below the VMD bridge, but
> > > ignore
> > > _OSC for hotplug control.
> >
> > Because VMD has its own hotplug BIOS setting which allows vmd to
> > enable or disable hotplug on its domain. However we don't have VMD
> > specific AER, DPC, LTR settings.
>
> I don't quite follow. The OS knows nothing about whether BIOS
> settings exist, so they can't be used to determine where _OSC
> applies.
>
> > Is it okay if we include an additional check for hotplug? i.e.
> > Hotplug capable bit in SltCap register which reflects VMD BIOS
> > hotplug setting.
>
> I don't know what check you have in mind, but the OS can definitely
> use SltCap to decide what features to enable.
Yes I agree. That is what I am also suggesting in this patch.
>
> You suggest above that you want vmd to be aware of AER ownership per
> _OSC, but it sounds more like you just want AER disabled below VMD
> regardless. Or do you have platforms that can actually handle AER
> interrupts from Root Ports below VMD?
No I dont want AER disabled below VMD all the time. I am suggesting vmd
should be in sync with all the _OSC flags since vmd doesn't give a
choice to toggle. However, the issue arises in guest where _OSC setting
for hotplug is always 0 eventhough hotplug is 1 in host and hotplug
enable bit in SltCap register is 1 in both host and guest. So we can
use that to enable hotplug in guest. Like you suggested in your above
comment.
>
> > Another way is to overwrite _OSC setting for hotplug only in Guest
> > OS. If we make VMD driver aware of Host or Guest environment, only
> > in case of Guest we overwrite _OSC hotplug using SltCap register
> > and
> > we don't revert the 04b12ef163d1.
>
> Making vmd aware of being in host or guest sounds kind of ugly to me.
I agree.
>
> Bjorn
next prev parent reply other threads:[~2023-12-14 22:15 UTC|newest]
Thread overview: 37+ messages / expand[flat|nested] mbox.gz Atom feed top
2023-11-27 21:17 [PATCH v2] PCI: vmd: Enable Hotplug based on BIOS setting on VMD rootports Nirmal Patel
2023-12-02 0:07 ` Bjorn Helgaas
2023-12-05 22:20 ` Nirmal Patel
2023-12-06 0:27 ` Bjorn Helgaas
2023-12-11 23:05 ` Nirmal Patel
2023-12-12 21:13 ` Bjorn Helgaas
2023-12-14 1:07 ` Nirmal Patel
2023-12-14 19:23 ` Bjorn Helgaas
2023-12-14 22:22 ` Nirmal Patel [this message]
2024-01-12 0:02 ` Nirmal Patel
2024-01-12 22:55 ` Bjorn Helgaas
2024-01-16 20:37 ` Nirmal Patel
2024-01-17 0:49 ` Bjorn Helgaas
2024-02-01 21:16 ` Bjorn Helgaas
2024-02-01 18:38 ` Nirmal Patel
2024-02-01 23:00 ` Bjorn Helgaas
2024-02-07 0:27 ` Nirmal Patel
2024-02-07 18:55 ` Bjorn Helgaas
2024-02-13 17:47 ` Nirmal Patel
2024-03-06 22:27 ` Nirmal Patel
2024-03-07 6:44 ` Kai-Heng Feng
2024-03-08 0:09 ` Nirmal Patel
2024-03-15 1:29 ` Kai-Heng Feng
2024-03-22 20:57 ` Nirmal Patel
2024-03-22 21:37 ` Bjorn Helgaas
2024-03-22 22:43 ` Paul M Stillwell Jr
2024-03-22 23:36 ` Bjorn Helgaas
2024-03-25 15:10 ` Paul M Stillwell Jr
2024-03-26 0:17 ` Nirmal Patel
2024-03-26 1:59 ` Kai-Heng Feng
2024-03-26 15:51 ` Paul M Stillwell Jr
2024-03-26 16:03 ` Paul M Stillwell Jr
2024-03-26 21:08 ` Bjorn Helgaas
2024-04-02 16:10 ` Paul M Stillwell Jr
2024-02-01 22:22 ` Bjorn Helgaas
2024-01-16 23:54 ` Bjorn Helgaas
2024-02-14 13:43 ` Lorenzo Pieralisi
Reply instructions:
You may reply publicly to this message via plain-text email
using any one of the following methods:
* Save the following mbox file, import it into your mail client,
and reply-to-all from there: mbox
Avoid top-posting and favor interleaved quoting:
https://en.wikipedia.org/wiki/Posting_style#Interleaved_style
* Reply using the --to, --cc, and --in-reply-to
switches of git-send-email(1):
git send-email \
--in-reply-to=24a4e9c73f6447f5bb67906c57520514dfa77389.camel@linux.intel.com \
--to=nirmal.patel@linux.intel.com \
--cc=helgaas@kernel.org \
--cc=linux-pci@vger.kernel.org \
--cc=samruddh.dhope@intel.com \
/path/to/YOUR_REPLY
https://kernel.org/pub/software/scm/git/docs/git-send-email.html
* If your mail client supports setting the In-Reply-To header
via mailto: links, try the mailto: link
Be sure your reply has a Subject: header at the top and a blank line
before the message body.
This is a public inbox, see mirroring instructions
for how to clone and mirror all data and code used for this inbox;
as well as URLs for NNTP newsgroup(s).