Testcase stat+json_output.sh fails in powerpc:

	86: perf stat JSON output linter : FAILED!

The testcase "stat+json_output.sh" verifies perf stat
JSON output. The test covers aggregation modes like
per-socket, per-core, per-die, -A (no_aggr mode) along
with few other tests. It counts expected fields for
various commands. For example say -A (i.e, AGGR_NONE
mode), expects 7 fields in the output having "CPU" as
first field. Same way, for per-socket, it expects the
first field in result to point to socket id. The testcases
compares the result with expected count.

The values for socket, die, core and cpu are fetched
from topology directory:
/sys/devices/system/cpu/cpu*/topology.
For example, socket value is fetched from
"physical_package_id" file of topology directory.
(cpu__get_topology_int() in util/cpumap.c)

If a platform fails to fetch the topology information,
values will be set to -1. For example, incase of pSeries
platform of powerpc, value for  "physical_package_id" is
restricted and not exposed. So, -1 will be assigned.

Perf code has a checks for valid cpu id in "aggr_printout"
(stat-display.c), which displays the fields. So, in cases
where topology values not exposed, first field of the
output displaying will be empty. This cause the testcase
to fail, as it counts  number of fields in the output.

Incase of -A (AGGR_NONE mode,), testcase expects 7 fields
in the output, becos of -1 value obtained from topology
files for some, only 6 fields are printed. Hence a testcase
failure reported due to mismatch in number of fields in
the output.

Patch here adds a sanity check in the testcase for topology.
Check will help to skip the test if -1 value found.

Fixes: 0c343af2a2f8 ("perf test: JSON format checking")
Reported-by: Disha Goel <disgoel@linux.vnet.ibm.com>
Signed-off-by: Athira Rajeev <atrajeev@linux.vnet.ibm.com>
Suggested-by: James Clark <james.clark@arm.com>
Suggested-by: Ian Rogers <irogers@google.com>
---
 tools/perf/tests/shell/stat+json_output.sh | 43 ++++++++++++++++++++--
 1 file changed, 39 insertions(+), 4 deletions(-)

diff --git a/tools/perf/tests/shell/stat+json_output.sh b/tools/perf/tests/shell/stat+json_output.sh
index ea8714a36051..2c4212c641ed 100755
--- a/tools/perf/tests/shell/stat+json_output.sh
+++ b/tools/perf/tests/shell/stat+json_output.sh
@@ -6,6 +6,8 @@
 
 set -e
 
+skip_test=0
+
 pythonchecker=$(dirname $0)/lib/perf_json_output_lint.py
 if [ "x$PYTHON" == "x" ]
 then
@@ -134,14 +136,47 @@ check_per_socket()
 	echo "[Success]"
 }
 
+# The perf stat options for per-socket, per-core, per-die
+# and -A ( no_aggr mode ) uses the info fetched from this
+# directory: "/sys/devices/system/cpu/cpu*/topology". For
+# example, socket value is fetched from "physical_package_id"
+# file in topology directory.
+# Reference: cpu__get_topology_int in util/cpumap.c
+# If the platform doesn't expose topology information, values
+# will be set to -1. For example, incase of pSeries platform
+# of powerpc, value for  "physical_package_id" is restricted
+# and set to -1. Check here validates the socket-id read from
+# topology file before proceeding further
+
+FILE_LOC="/sys/devices/system/cpu/cpu*/topology/"
+FILE_NAME="physical_package_id"
+
+check_for_topology()
+{
+	if ! ParanoidAndNotRoot 0
+	then
+		socket_file=`ls $FILE_LOC/$FILE_NAME | head -n 1`
+		[ -z $socket_file ] && return 0
+		socket_id=`cat $socket_file`
+		[ $socket_id == -1 ] && skip_test=1
+		return 0
+	fi
+}
+
+check_for_topology
 check_no_args
 check_system_wide
-check_system_wide_no_aggr
 check_interval
 check_event
-check_per_core
 check_per_thread
-check_per_die
 check_per_node
-check_per_socket
+if [ $skip_test -ne 1 ]
+then
+	check_system_wide_no_aggr
+	check_per_core
+	check_per_die
+	check_per_socket
+else
+	echo "[Skip] Skipping tests for system_wide_no_aggr, per_core, per_die and per_socket since socket id exposed via topology is invalid"
+fi
 exit 0
-- 
2.31.1


  reply	other threads:[~2022-10-06 15:52 UTC|newest]

Thread overview: 4+ messages / expand[flat|nested]  mbox.gz  Atom feed  top
2022-10-06 15:51 [PATCH 1/2] tools/perf/tests/shell: Update stat+csv_output.sh to include sanity check for topology Athira Rajeev
2022-10-06 15:51 ` Athira Rajeev [this message]
2022-10-14 20:22 ` Arnaldo Carvalho de Melo
2022-10-17 15:39 ` Disha Goel

Reply instructions:

You may reply publicly to this message via plain-text email
using any one of the following methods:

* Save the following mbox file, import it into your mail client,
  and reply-to-all from there: mbox

  Avoid top-posting and favor interleaved quoting:
  https://en.wikipedia.org/wiki/Posting_style#Interleaved_style

* Reply using the --to, --cc, and --in-reply-to
  switches of git-send-email(1):

  git send-email \
    --in-reply-to=20221006155149.67205-2-atrajeev@linux.vnet.ibm.com \
    --to=atrajeev@linux.vnet.ibm.com \
    --cc=acme@kernel.org \
    --cc=disgoel@linux.vnet.ibm.com \
    --cc=jolsa@kernel.org \
    --cc=kjain@linux.ibm.com \
    --cc=linux-perf-users@vger.kernel.org \
    --cc=linuxppc-dev@lists.ozlabs.org \
    --cc=maddy@linux.vnet.ibm.com \
    --cc=mpe@ellerman.id.au \
    --cc=rnsastry@linux.ibm.com \
    /path/to/YOUR_REPLY

  https://kernel.org/pub/software/scm/git/docs/git-send-email.html

* If your mail client supports setting the In-Reply-To header
  via mailto: links, try the mailto: link
Be sure your reply has a Subject: header at the top and a blank line before the message body.
This is a public inbox, see mirroring instructions
for how to clone and mirror all data and code used for this inbox;
as well as URLs for NNTP newsgroup(s).