linux-pm.vger.kernel.org archive mirror
 help / color / mirror / Atom feed
From: Daniel Lezcano <daniel.lezcano@linaro.org>
To: Thara Gopinath <thara.gopinath@linaro.org>,
	Zhang Rui <rui.zhang@intel.com>, Rob Herring <robh+dt@kernel.org>,
	Andy Gross <agross@kernel.org>,
	Bjorn Andersson <bjorn.andersson@linaro.org>
Cc: Linux PM list <linux-pm@vger.kernel.org>,
	"open list:OPEN FIRMWARE AND FLATTENED DEVICE TREE BINDINGS" 
	<devicetree@vger.kernel.org>,
	linux-kernel <linux-kernel@vger.kernel.org>,
	linux-arm-msm <linux-arm-msm@vger.kernel.org>,
	lukasz.luba@arm.com, amitk@kernel.org
Subject: Re: [PATCH RFC 0/8] Introduce warming in thermal framework
Date: Mon, 19 Oct 2020 21:22:59 +0200	[thread overview]
Message-ID: <12160a98-bf04-939c-0149-018db8affe08@linaro.org> (raw)
In-Reply-To: <CALD-y_wQeuUq=0+_TGWYwOAcM4zdmGbtCMYZ+Oa587HtzHHqVQ@mail.gmail.com>

On 19/10/2020 20:42, Thara Gopinath wrote:
> On Wed, 16 Sep 2020 at 23:22, Thara Gopinath <thara.gopinath@linaro.org> wrote:
>>
>> Thermal framework today supports monitoring for rising temperatures and
>> subsequently initiating cooling action in case of a thermal trip point
>> being crossed. There are scenarios where a SoC need warming mitigating
>> action to be activated if the temperature falls below a cetain permissible
>> limit.  Since warming action can be considered mirror opposite of cooling
>> action, most of the thermal framework can be re-used to achieve this. The
>> key assumption in this patch series is that a device can act either as a
>> warming device or a cooling device and not as both.
>>
>> In order to support warming three extensions are needed in the thermal
>> framework.
>>
>> 1. Indication that a trip point is being monitored for falling temperature
>> and not rising temperature. We discussed two different ways to achieve this
>> during LPC. First option is to introduce a new trip type to indicate that a
>> trip is a cold trip(THERMAL_TRIP_COLD). The second option is to introduce a
>> new property for trip point that will indicate whether a trip point is
>> being monitored for rising temperature or falling temperature. The patch
>> series(patches 1-4) chooses the second approach since it allows trip points
>> of any type to be monitored for rising or falling temperature.Also this was
>> the preferred approach when discussed during LPC. The approach that
>> introduces a new cold trip type was posted on the list earlier as a RFC and
>> can be found at [1].
>>
>> 2. Extend the exisitng governors to handle monitoring of falling
>> temperature. The patch series(patches 5 & 6) extends the step wise governor
>> to monitor the falling temperature.Other governors return doing nothing if
>> the trip point they are being called for is being monitored for falling
>> temperature. The governors' mitigate function is called "throttle" in the
>> thermal framework and with this patch series it is a misnomer as the
>> function is called for both throttling and warming up. Ideally
>> "throttle" should be renamed to "mitigate" to improve readability of code.
>> The renaming is not part of this series.
>>
>> 3. Finally, the cooling device framework itself can be reused for a warming
>> device. As stated before a device can act either as a warming device or a
>> cooling device and not as both.  With this the cooling state in the
>> framework can be considered as mitigating state with 0 as the state with no
>> thermal mitigation and higher the number higher the thermal mitigation.
>> Again what affects the code readability and comprehension is the term
>> "cooling" which is a misnomer here. Ideally the term "cooling" should be
>> renamed to "mitigating" and hence thermal_cooling_device will become
>> thermal_mitgating_device. The renaming is not part of the patch series as
>> even though the renaming is a simple search-replace, it will change a lot
>> of files.  The patch series(patches 7 & 8) instead introduces a minimal set
>> of _warming_device_ apis to register and unregister warming devices which
>> internally is identical to the _cooling_device_ counterpart.
> 
> Gentle ping for review..

Pong, review before the end of this week.



-- 
<http://www.linaro.org/> Linaro.org │ Open source software for ARM SoCs

Follow Linaro:  <http://www.facebook.com/pages/Linaro> Facebook |
<http://twitter.com/#!/linaroorg> Twitter |
<http://www.linaro.org/linaro-blog/> Blog

      reply	other threads:[~2020-10-19 19:23 UTC|newest]

Thread overview: 13+ messages / expand[flat|nested]  mbox.gz  Atom feed  top
2020-09-17  3:22 [PATCH RFC 0/8] Introduce warming in thermal framework Thara Gopinath
2020-09-17  3:22 ` [PATCH RFC 1/8] dt-bindings: thermal: Introduce monitor-falling parameter to thermal trip point binding Thara Gopinath
2020-09-23 16:03   ` Rob Herring
2020-09-28 11:21     ` Thara Gopinath
2020-09-17  3:22 ` [PATCH RFC 2/8] thermal: Introduce new property monitor_type for trip point Thara Gopinath
2020-09-17  3:22 ` [PATCH RFC 3/8] thermal: thermal_of: Extend thermal dt driver to support bi-directional monitoring of a thermal " Thara Gopinath
2020-09-17  3:22 ` [PATCH RFC 4/8] thermal:core:Add genetlink notifications for monitoring falling temperature Thara Gopinath
2020-09-17  3:22 ` [PATCH RFC 5/8] thermal: gov_step_wise: Extend thermal step-wise governor to monitor " Thara Gopinath
2020-09-17  3:22 ` [PATCH RFC 6/8] thermal: Modify thermal governors to do nothing for trip points being monitored for " Thara Gopinath
2020-09-17  3:22 ` [PATCH RFC 7/8] thermal:core: Add is_warming_dev and supporting warming device api's to the cooling dev framework Thara Gopinath
2020-09-17  3:22 ` [PATCH RFC 8/8] soc:qcom:qcom_aoss: Change cooling_device_register to warming_device_register Thara Gopinath
2020-10-19 18:42 ` [PATCH RFC 0/8] Introduce warming in thermal framework Thara Gopinath
2020-10-19 19:22   ` Daniel Lezcano [this message]

Reply instructions:

You may reply publicly to this message via plain-text email
using any one of the following methods:

* Save the following mbox file, import it into your mail client,
  and reply-to-all from there: mbox

  Avoid top-posting and favor interleaved quoting:
  https://en.wikipedia.org/wiki/Posting_style#Interleaved_style

* Reply using the --to, --cc, and --in-reply-to
  switches of git-send-email(1):

  git send-email \
    --in-reply-to=12160a98-bf04-939c-0149-018db8affe08@linaro.org \
    --to=daniel.lezcano@linaro.org \
    --cc=agross@kernel.org \
    --cc=amitk@kernel.org \
    --cc=bjorn.andersson@linaro.org \
    --cc=devicetree@vger.kernel.org \
    --cc=linux-arm-msm@vger.kernel.org \
    --cc=linux-kernel@vger.kernel.org \
    --cc=linux-pm@vger.kernel.org \
    --cc=lukasz.luba@arm.com \
    --cc=robh+dt@kernel.org \
    --cc=rui.zhang@intel.com \
    --cc=thara.gopinath@linaro.org \
    /path/to/YOUR_REPLY

  https://kernel.org/pub/software/scm/git/docs/git-send-email.html

* If your mail client supports setting the In-Reply-To header
  via mailto: links, try the mailto: link
Be sure your reply has a Subject: header at the top and a blank line before the message body.
This is a public inbox, see mirroring instructions
for how to clone and mirror all data and code used for this inbox;
as well as URLs for NNTP newsgroup(s).