* [RFC PATCH 0/12] generic thermal layer enhancement
@ 2012-06-11 3:19 Zhang Rui
2012-06-11 9:49 ` Eduardo Valentin
2012-06-19 11:31 ` R, Durgadoss
0 siblings, 2 replies; 4+ messages in thread
From: Zhang Rui @ 2012-06-11 3:19 UTC (permalink / raw)
To: linux-pm, linux-acpi@vger.kernel.org
Hi, all,
this patch set is made to enhance the current generic thermal layer.
It fixes several gaps discussed in
http://marc.info/?l=linux-acpi&m=133836783425764&w=2
and introduces a simple arbitrator to fix the "one cooling devices
referenced by multiple trip points in multiple thermal zones" problem.
The whole idea is
1) make sure we have multiple cooling states for both active cooling and
passive cooling devices. (patch 1,2,3)
2) remove passive specific requirement, aka, tc1/tc2, and
introduce .get_trend() instead, for both active and passive cooling
algorithm. (patch 4,5)
3) introduce new function thermal_zone_trip_update(), this contains the
code for the general cooling algorithm. (patch 6)
4) rename some thermal structures. Use thermal_instance instead of
thermal_cooling_device_instance, as this structure is used to
describe the behavior of a certain cooling device for a certain trip
point in a certain thermal zone.
thermal_zone_device has a list of all the thermal instances in this
thermal zone so that it can update them when the temperature changes.
thermal_cooling_device has a list of all the thermal instances for
this cooling device so that it can make decision which cooling state
should be in when the temperature changes. (patch 7,8,9,10)
5) introduce a simple arbitrator. (patch 11)
When temperature changes, we update a thermal zone in two stages,
a) thermal_zone_trip_point() is the general cooling algorithm to
update the thermal instances in the thermal zone device
b) thermal_zone_do_update() is the arbitrator for the cooling device
to choose the deepest cooling state required to enter.
6) unify the code for both passive and active cooling.
TODO, add locking mechanism. I know this is important but as this patch
set changes the thermal layer a lot, I just want to make sure I'm in the
right direction before going on.
BTW, in theory, they should make no change to the behavior of the
current generic thermal layer users. But I have just done the build
test.
Any comments are welcome.
thanks,
rui
--------------------------------------------------------------------
drivers/acpi/thermal.c | 76 +++++++--
drivers/platform/x86/acerhdf.c | 4 +-
drivers/platform/x86/intel_mid_thermal.c | 2 +-
drivers/thermal/spear_thermal.c | 2 +-
drivers/thermal/thermal_sys.c | 293
++++++++++++++++++------------
include/linux/thermal.h | 22 ++-
7 files changed, 271 insertions(+), 148 deletions(-)
^ permalink raw reply [flat|nested] 4+ messages in thread* Re: [RFC PATCH 0/12] generic thermal layer enhancement 2012-06-11 3:19 [RFC PATCH 0/12] generic thermal layer enhancement Zhang Rui @ 2012-06-11 9:49 ` Eduardo Valentin 2012-06-12 3:01 ` Zhang Rui 2012-06-19 11:31 ` R, Durgadoss 1 sibling, 1 reply; 4+ messages in thread From: Eduardo Valentin @ 2012-06-11 9:49 UTC (permalink / raw) To: Zhang Rui Cc: linux-pm, linux-acpi@vger.kernel.org, Amit Kachhap, R, Durgadoss, Rafael J. Wysocki, eduardo, Len, Brown, Matthew Garrett Hello Rui, On Mon, Jun 11, 2012 at 11:19:11AM +0800, Zhang Rui wrote: > Hi, all, > > this patch set is made to enhance the current generic thermal layer. > It fixes several gaps discussed in > http://marc.info/?l=linux-acpi&m=133836783425764&w=2 > and introduces a simple arbitrator to fix the "one cooling devices > referenced by multiple trip points in multiple thermal zones" problem. Thanks for taking this further. With code it is much better to progress. BTW, are you keeping this series somewhere in a branch? > > The whole idea is > 1) make sure we have multiple cooling states for both active cooling and > passive cooling devices. (patch 1,2,3) Nice! > 2) remove passive specific requirement, aka, tc1/tc2, and > introduce .get_trend() instead, for both active and passive cooling > algorithm. (patch 4,5) Cool. The .get_trend() might be also helpful in case there are sensors that provide trending computation, or at least, some history buffer. So, I definitely agree with this approach. > 3) introduce new function thermal_zone_trip_update(), this contains the > code for the general cooling algorithm. (patch 6) Ok. > 4) rename some thermal structures. Use thermal_instance instead of > thermal_cooling_device_instance, as this structure is used to > describe the behavior of a certain cooling device for a certain trip > point in a certain thermal zone. > thermal_zone_device has a list of all the thermal instances in this > thermal zone so that it can update them when the temperature changes. > thermal_cooling_device has a list of all the thermal instances for > this cooling device so that it can make decision which cooling state > should be in when the temperature changes. (patch 7,8,9,10) Ok. > 5) introduce a simple arbitrator. (patch 11) > When temperature changes, we update a thermal zone in two stages, > a) thermal_zone_trip_point() is the general cooling algorithm to > update the thermal instances in the thermal zone device > b) thermal_zone_do_update() is the arbitrator for the cooling device > to choose the deepest cooling state required to enter. The arbitrator is good starting point. I will have a deeper look on it. But we may be careful to solve the constraint issue only at thermal code level. There might be conflicting constraints coming from PM QoS layer, for instance. > 6) unify the code for both passive and active cooling. This is good. > > TODO, add locking mechanism. I know this is important but as this patch > set changes the thermal layer a(lot, I just want to make sure I'm in the > right direction before going on. Right. I second you on the incremental approach. > > BTW, in theory, they should make no change to the behavior of the > current generic thermal layer users. But I have just done the build > test. OK. I will fetch them and give them a trial on my side, then send better review. > > Any comments are welcome. > > thanks, > rui > > -------------------------------------------------------------------- > drivers/acpi/thermal.c | 76 +++++++-- > drivers/platform/x86/acerhdf.c | 4 +- > drivers/platform/x86/intel_mid_thermal.c | 2 +- > driverk/thermal/spear_thermal.c | 2 +- > drivers/thermal/thermal_sys.c | 293 > ++++++++++++++++++------------ > include/linux/thermal.h | 22 ++- > 7 files changed, 271 insertions(+), 148 deletions(-) > > -- Eduardo Valentin ^ permalink raw reply [flat|nested] 4+ messages in thread
* Re: [RFC PATCH 0/12] generic thermal layer enhancement 2012-06-11 9:49 ` Eduardo Valentin @ 2012-06-12 3:01 ` Zhang Rui 0 siblings, 0 replies; 4+ messages in thread From: Zhang Rui @ 2012-06-12 3:01 UTC (permalink / raw) To: eduardo.valentin Cc: linux-pm, linux-acpi@vger.kernel.org, Amit Kachhap, R, Durgadoss, Rafael J. Wysocki, Len, Brown, Matthew Garrett On 一, 2012-06-11 at 12:49 +0300, Eduardo Valentin wrote: > Hello Rui, > > On Mon, Jun 11, 2012 at 11:19:11AM +0800, Zhang Rui wrote: > > Hi, all, > > > > this patch set is made to enhance the current generic thermal layer. > > It fixes several gaps discussed in > > http://marc.info/?l=linux-acpi&m=133836783425764&w=2 > > and introduces a simple arbitrator to fix the "one cooling devices > > referenced by multiple trip points in multiple thermal zones" problem. > > Thanks for taking this further. With code it is much better to progress. > > BTW, are you keeping this series somewhere in a branch? > Not yet. But I'm thinking of create one. :) > > > > The whole idea is > > 1) make sure we have multiple cooling states for both active cooling and > > passive cooling devices. (patch 1,2,3) > > Nice! > > > 2) remove passive specific requirement, aka, tc1/tc2, and > > introduce .get_trend() instead, for both active and passive cooling > > algorithm. (patch 4,5) > > Cool. The .get_trend() might be also helpful in case there are sensors > that provide trending computation, or at least, some history buffer. > > So, I definitely agree with this approach. > > > 3) introduce new function thermal_zone_trip_update(), this contains the > > code for the general cooling algorithm. (patch 6) > > Ok. > > > 4) rename some thermal structures. Use thermal_instance instead of > > thermal_cooling_device_instance, as this structure is used to > > describe the behavior of a certain cooling device for a certain trip > > point in a certain thermal zone. > > thermal_zone_device has a list of all the thermal instances in this > > thermal zone so that it can update them when the temperature changes. > > thermal_cooling_device has a list of all the thermal instances for > > this cooling device so that it can make decision which cooling state > > should be in when the temperature changes. (patch 7,8,9,10) > > Ok. > > > 5) introduce a simple arbitrator. (patch 11) > > When temperature changes, we update a thermal zone in two stages, > > a) thermal_zone_trip_point() is the general cooling algorithm to > > update the thermal instances in the thermal zone device > > b) thermal_zone_do_update() is the arbitrator for the cooling device > > to choose the deepest cooling state required to enter. > > The arbitrator is good starting point. I will have a deeper look on it. > > But we may be careful to solve the constraint issue only at thermal code > level. There might be conflicting constraints coming from PM QoS layer, > for instance. > hmmm, do you have a link for the discussions/patches mentioned? I'll take a look at this. :) > > 6) unify the code for both passive and active cooling. > > This is good. > > > > > TODO, add locking mechanism. I know this is important but as this patch > > set changes the thermal layer a(lot, I just want to make sure I'm in the > > right direction before going on. > > Right. I second you on the incremental approach. > > > > > BTW, in theory, they should make no change to the behavior of the > > current generic thermal layer users. But I have just done the build > > test. > > OK. I will fetch them and give them a trial on my side, then send better review. > Great. That would be really helpful. Thanks for your interest on this, Eduardo! :) -rui -- To unsubscribe from this list: send the line "unsubscribe linux-acpi" in the body of a message to majordomo@vger.kernel.org More majordomo info at http://vger.kernel.org/majordomo-info.html ^ permalink raw reply [flat|nested] 4+ messages in thread
* RE: [RFC PATCH 0/12] generic thermal layer enhancement 2012-06-11 3:19 [RFC PATCH 0/12] generic thermal layer enhancement Zhang Rui 2012-06-11 9:49 ` Eduardo Valentin @ 2012-06-19 11:31 ` R, Durgadoss 1 sibling, 0 replies; 4+ messages in thread From: R, Durgadoss @ 2012-06-19 11:31 UTC (permalink / raw) To: Zhang, Rui, linux-pm, linux-acpi@vger.kernel.org Cc: Amit Kachhap, eduardo, Len, Brown, Matthew Garrett Hi All, > The whole idea is > 1) make sure we have multiple cooling states for both active cooling and > passive cooling devices. (patch 1,2,3) > 2) remove passive specific requirement, aka, tc1/tc2, and > introduce .get_trend() instead, for both active and passive cooling > algorithm. (patch 4,5) > 3) introduce new function thermal_zone_trip_update(), this contains the > code for the general cooling algorithm. (patch 6) > 4) rename some thermal structures. Use thermal_instance instead of > thermal_cooling_device_instance, as this structure is used to > describe the behavior of a certain cooling device for a certain trip > point in a certain thermal zone. > thermal_zone_device has a list of all the thermal instances in this > thermal zone so that it can update them when the temperature changes. > thermal_cooling_device has a list of all the thermal instances for > this cooling device so that it can make decision which cooling state > should be in when the temperature changes. (patch 7,8,9,10) > 5) introduce a simple arbitrator. (patch 11) > When temperature changes, we update a thermal zone in two stages, > a) thermal_zone_trip_point() is the general cooling algorithm to > update the thermal instances in the thermal zone device > b) thermal_zone_do_update() is the arbitrator for the cooling device > to choose the deepest cooling state required to enter. > 6) unify the code for both passive and active cooling. > > TODO, add locking mechanism. I know this is important but as this patch > set changes the thermal layer a lot, I just want to make sure I'm in the > right direction before going on. > > BTW, in theory, they should make no change to the behavior of the > current generic thermal layer users. But I have just done the build > test. I talked to Rui about this patch set and my other patch sets. Rui suggested me to rebase my patches on top of his changes. So, I hope Rui will be able to clean up these 12 patches and submit them (in a week's time :-) I will rebase my patches on top of them. Also, Rui promised me that he can host a tree for us to easily pick up changes, Let us see :-) Thanks, Durga ^ permalink raw reply [flat|nested] 4+ messages in thread
end of thread, other threads:[~2012-06-19 11:31 UTC | newest] Thread overview: 4+ messages (download: mbox.gz follow: Atom feed -- links below jump to the message on this page -- 2012-06-11 3:19 [RFC PATCH 0/12] generic thermal layer enhancement Zhang Rui 2012-06-11 9:49 ` Eduardo Valentin 2012-06-12 3:01 ` Zhang Rui 2012-06-19 11:31 ` R, Durgadoss
This is a public inbox, see mirroring instructions for how to clone and mirror all data and code used for this inbox