From: Zhang Rui <rui.zhang@intel.com>
To: linux-pm@vger.kernel.org
Cc: amit.daniel@samsung.com, gu1@aeroxteam.fr,
hongbo.zhang@linaro.org, Zhang Rui <rui.zhang@intel.com>
Subject: [PATCH V3 2/2] Thermal: exynos: fix cooling state translation
Date: Mon, 11 Mar 2013 23:33:13 +0800 [thread overview]
Message-ID: <1363015993-8113-3-git-send-email-rui.zhang@intel.com> (raw)
In-Reply-To: <1363015993-8113-1-git-send-email-rui.zhang@intel.com>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
---
drivers/thermal/cpu_cooling.c | 11 +++++++++++
drivers/thermal/exynos_thermal.c | 24 ++----------------------
include/linux/cpu_cooling.h | 7 +++++++
include/linux/thermal.h | 5 ++++-
4 files changed, 24 insertions(+), 23 deletions(-)
diff --git a/drivers/thermal/cpu_cooling.c b/drivers/thermal/cpu_cooling.c
index 9e208d3..e03891b 100644
--- a/drivers/thermal/cpu_cooling.c
+++ b/drivers/thermal/cpu_cooling.c
@@ -196,6 +196,17 @@ static int get_property(unsigned int cpu, unsigned long input,
return -EINVAL;
}
+unsigned long cpufreq_cooling_get_level(unsigned int cpu, unsigned int freq)
+{
+ unsigned int val;
+
+ if (get_property(cpu, (unsigned long)freq, &val, GET_LEVEL))
+ return THERMAL_CSTATE_INVALID;
+ return (unsigned long)val;
+}
+
+EXPORT_SYMBOL(cpufreq_cooling_get_level);
+
/**
* get_cpu_frequency - get the absolute value of frequency from level.
* @cpu: cpu for which frequency is fetched.
diff --git a/drivers/thermal/exynos_thermal.c b/drivers/thermal/exynos_thermal.c
index 46568c0..5412578 100644
--- a/drivers/thermal/exynos_thermal.c
+++ b/drivers/thermal/exynos_thermal.c
@@ -242,26 +242,6 @@ static int exynos_get_crit_temp(struct thermal_zone_device *thermal,
return ret;
}
-static int exynos_get_frequency_level(unsigned int cpu, unsigned int freq)
-{
- int i = 0, ret = -EINVAL;
- struct cpufreq_frequency_table *table = NULL;
-#ifdef CONFIG_CPU_FREQ
- table = cpufreq_frequency_get_table(cpu);
-#endif
- if (!table)
- return ret;
-
- while (table[i].frequency != CPUFREQ_TABLE_END) {
- if (table[i].frequency == CPUFREQ_ENTRY_INVALID)
- continue;
- if (table[i].frequency == freq)
- return i;
- i++;
- }
- return ret;
-}
-
/* Bind callback functions for thermal zone */
static int exynos_bind(struct thermal_zone_device *thermal,
struct thermal_cooling_device *cdev)
@@ -288,8 +268,8 @@ static int exynos_bind(struct thermal_zone_device *thermal,
/* Bind the thermal zone to the cpufreq cooling device */
for (i = 0; i < tab_size; i++) {
clip_data = (struct freq_clip_table *)&(tab_ptr[i]);
- level = exynos_get_frequency_level(0, clip_data->freq_clip_max);
- if (level < 0)
+ level = cpufreq_cooling_get_level(0, clip_data->freq_clip_max);
+ if (level == THERMAL_CSTATE_INVALID)
return 0;
switch (GET_ZONE(i)) {
case MONITOR_ZONE:
diff --git a/include/linux/cpu_cooling.h b/include/linux/cpu_cooling.h
index 40b4ef5..bc479b1 100644
--- a/include/linux/cpu_cooling.h
+++ b/include/linux/cpu_cooling.h
@@ -42,6 +42,8 @@ struct thermal_cooling_device *cpufreq_cooling_register(
* @cdev: thermal cooling device pointer.
*/
void cpufreq_cooling_unregister(struct thermal_cooling_device *cdev);
+
+unsigned long cpufreq_cooling_get_level(unsigned int, unsigned int);
#else /* !CONFIG_CPU_THERMAL */
static inline struct thermal_cooling_device *cpufreq_cooling_register(
const struct cpumask *clip_cpus)
@@ -53,6 +55,11 @@ static inline void cpufreq_cooling_unregister(
{
return;
}
+static inline unsigned long cpufreq_cooling_get_level(unsigned int,
+ unsigned int)
+{
+ return THERMAL_CSTATE_INVALID;
+}
#endif /* CONFIG_CPU_THERMAL */
#endif /* __CPU_COOLING_H__ */
diff --git a/include/linux/thermal.h b/include/linux/thermal.h
index f0bd7f9..5a3b428 100644
--- a/include/linux/thermal.h
+++ b/include/linux/thermal.h
@@ -33,8 +33,11 @@
#define THERMAL_MAX_TRIPS 12
#define THERMAL_NAME_LENGTH 20
+/* invalid cooling state */
+#define THERMAL_CSTATE_INVALID -1UL
+
/* No upper/lower limit requirement */
-#define THERMAL_NO_LIMIT -1UL
+#define THERMAL_NO_LIMIT THERMAL_CSTATE_INVALID
/* Unit conversion macros */
#define KELVIN_TO_CELSIUS(t) (long)(((long)t-2732 >= 0) ? \
--
1.7.9.5
prev parent reply other threads:[~2013-03-11 15:33 UTC|newest]
Thread overview: 3+ messages / expand[flat|nested] mbox.gz Atom feed top
2013-03-11 15:33 [PATCH V3 0/2] Thermal: cpufreq cooling fix Zhang Rui
2013-03-11 15:33 ` [PATCH V3 1/2] Thermal: cpufreq cooling: fix parsing per_cpu cpufreq_frequency_table Zhang Rui
2013-03-11 15:33 ` Zhang Rui [this message]
Reply instructions:
You may reply publicly to this message via plain-text email
using any one of the following methods:
* Save the following mbox file, import it into your mail client,
and reply-to-all from there: mbox
Avoid top-posting and favor interleaved quoting:
https://en.wikipedia.org/wiki/Posting_style#Interleaved_style
* Reply using the --to, --cc, and --in-reply-to
switches of git-send-email(1):
git send-email \
--in-reply-to=1363015993-8113-3-git-send-email-rui.zhang@intel.com \
--to=rui.zhang@intel.com \
--cc=amit.daniel@samsung.com \
--cc=gu1@aeroxteam.fr \
--cc=hongbo.zhang@linaro.org \
--cc=linux-pm@vger.kernel.org \
/path/to/YOUR_REPLY
https://kernel.org/pub/software/scm/git/docs/git-send-email.html
* If your mail client supports setting the In-Reply-To header
via mailto: links, try the mailto: link
Be sure your reply has a Subject: header at the top and a blank line
before the message body.
This is a public inbox, see mirroring instructions
for how to clone and mirror all data and code used for this inbox;
as well as URLs for NNTP newsgroup(s).