* [PATCH] thermal: imx: Do NOT return -EPROBE_DEFER when "#cooling-cells" is present
@ 2020-10-22 4:24 Anson Huang
0 siblings, 0 replies; only message in thread
From: Anson Huang @ 2020-10-22 4:24 UTC (permalink / raw)
To: rui.zhang, daniel.lezcano, amitk, shawnguo, s.hauer, kernel,
festevam, linux-pm, linux-arm-kernel, linux-kernel
Cc: Linux-imx
The legacy CPU cooling should ONLY be used when "#cooling-cells" is NOT
present in cpu node, current implementation for registering legacy cooling
always return -EPROBE_DEFER when cpufreq is NOT ready, that will cause
thermal driver probe failed when cpufreq failed to probe with a non
-EPROBE_DEFER reason. In such case, thermal driver should continue probe
and provide temperature monitor and other cooling methods.
So, for the case of "#cooling-cells" present in cpu node, no need to
return -EPROBE_DEFER even cpufreq is NOT ready, this is to make sure
thermal driver can continue probe.
Signed-off-by: Anson Huang <Anson.Huang@nxp.com>
---
drivers/thermal/imx_thermal.c | 25 +++++++++++++++++++------
1 file changed, 19 insertions(+), 6 deletions(-)
diff --git a/drivers/thermal/imx_thermal.c b/drivers/thermal/imx_thermal.c
index 9f00182..df60dcb 100644
--- a/drivers/thermal/imx_thermal.c
+++ b/drivers/thermal/imx_thermal.c
@@ -630,17 +630,29 @@ MODULE_DEVICE_TABLE(of, of_imx_thermal_match);
static int imx_thermal_register_legacy_cooling(struct imx_thermal_data *data)
{
struct device_node *np;
+ struct device *cpu_dev;
int ret = 0;
- data->policy = cpufreq_cpu_get(0);
- if (!data->policy) {
- pr_debug("%s: CPUFreq policy not found\n", __func__);
- return -EPROBE_DEFER;
+ cpu_dev = get_cpu_device(0);
+ if (!cpu_dev) {
+ pr_err("imx thermal: failed to get cpu0 device\n");
+ return -ENODEV;
+ }
+
+ np = of_node_get(cpu_dev->of_node);
+ if (!np) {
+ pr_err("imx thermal: failed to find cpu0 node\n");
+ return -ENOENT;
}
- np = of_get_cpu_node(data->policy->cpu, NULL);
+ if (!of_find_property(np, "#cooling-cells", NULL)) {
+ data->policy = cpufreq_cpu_get(0);
+ if (!data->policy) {
+ pr_debug("%s: CPUFreq policy not found\n", __func__);
+ ret = -EPROBE_DEFER;
+ goto put_node;
+ }
- if (!np || !of_find_property(np, "#cooling-cells", NULL)) {
data->cdev = cpufreq_cooling_register(data->policy);
if (IS_ERR(data->cdev)) {
ret = PTR_ERR(data->cdev);
@@ -648,6 +660,7 @@ static int imx_thermal_register_legacy_cooling(struct imx_thermal_data *data)
}
}
+put_node:
of_node_put(np);
return ret;
--
2.7.4
^ permalink raw reply related [flat|nested] only message in thread
only message in thread, other threads:[~2020-10-22 4:30 UTC | newest]
Thread overview: (only message) (download: mbox.gz follow: Atom feed
-- links below jump to the message on this page --
2020-10-22 4:24 [PATCH] thermal: imx: Do NOT return -EPROBE_DEFER when "#cooling-cells" is present Anson Huang
This is a public inbox, see mirroring instructions
for how to clone and mirror all data and code used for this inbox;
as well as URLs for NNTP newsgroup(s).