From: Eduardo Valentin <edubezval@gmail.com>
To: Srinivas Kandagatla <srinivas.kandagatla@linaro.org>
Cc: linux-pm@vger.kernel.org, Zhang Rui <rui.zhang@intel.com>,
	linux-kernel@vger.kernel.org, devicetree@vger.kernel.org,
	Rob Herring <robh+dt@kernel.org>
Subject: Re: [PATCH v2] thermal: Fix examples in DT documentation
Date: Wed, 28 Jan 2015 13:29:31 -0400	[thread overview]
Message-ID: <20150128172929.GA27003@developer.hsd1.ca.comcast.net> (raw)
In-Reply-To: <1422465215-12716-1-git-send-email-srinivas.kandagatla@linaro.org>

[-- Attachment #1: Type: text/plain, Size: 8120 bytes --]

On Wed, Jan 28, 2015 at 05:13:35PM +0000, Srinivas Kandagatla wrote:
> There are various issues with the examples in this documentation, some
> of the DT labels are invalid and one of the macro THERMAL_NO_LIMITS
> referenced is not available as well.
> 
> This patch attempts to fix such errors in the documentation.
> 
> Signed-off-by: Srinivas Kandagatla <srinivas.kandagatla@linaro.org>
> ---
> Changes Since v1:
> 	- Fixed few more typo's as suggested by Eduardo Valentin

Looks like there are still occurencies of adc-dummy after your patch.
But I am amending myself, no need to resend.

> 
>  .../devicetree/bindings/thermal/thermal.txt        | 66 +++++++++++-----------
>  1 file changed, 33 insertions(+), 33 deletions(-)
> 
> diff --git a/Documentation/devicetree/bindings/thermal/thermal.txt b/Documentation/devicetree/bindings/thermal/thermal.txt
> index f5db6b7..91c77da 100644
> --- a/Documentation/devicetree/bindings/thermal/thermal.txt
> +++ b/Documentation/devicetree/bindings/thermal/thermal.txt
> @@ -251,24 +251,24 @@ ocp {
>  };
>  
>  thermal-zones {
> -	cpu-thermal: cpu-thermal {
> +	cpu_thermal: cpu-thermal {
>  		polling-delay-passive = <250>; /* milliseconds */
>  		polling-delay = <1000>; /* milliseconds */
>  
>  		thermal-sensors = <&bandgap0>;
>  
>  		trips {
> -			cpu-alert0: cpu-alert {
> +			cpu_alert0: cpu-alert0 {
>  				temperature = <90000>; /* millicelsius */
>  				hysteresis = <2000>; /* millicelsius */
>  				type = "active";
>  			};
> -			cpu-alert1: cpu-alert {
> +			cpu_alert1: cpu-alert1 {
>  				temperature = <100000>; /* millicelsius */
>  				hysteresis = <2000>; /* millicelsius */
>  				type = "passive";
>  			};
> -			cpu-crit: cpu-crit {
> +			cpu_crit: cpu-crit {
>  				temperature = <125000>; /* millicelsius */
>  				hysteresis = <2000>; /* millicelsius */
>  				type = "critical";
> @@ -277,17 +277,17 @@ thermal-zones {
>  
>  		cooling-maps {
>  			map0 {
> -				trip = <&cpu-alert0>;
> -				cooling-device = <&fan0 THERMAL_NO_LIMITS 4>;
> +				trip = <&cpu_alert0>;
> +				cooling-device = <&fan0 THERMAL_NO_LIMIT 4>;
>  			};
>  			map1 {
> -				trip = <&cpu-alert1>;
> -				cooling-device = <&fan0 5 THERMAL_NO_LIMITS>;
> +				trip = <&cpu_alert1>;
> +				cooling-device = <&fan0 5 THERMAL_NO_LIMIT>;
>  			};
>  			map2 {
> -				trip = <&cpu-alert1>;
> +				trip = <&cpu_alert1>;
>  				cooling-device =
> -				    <&cpu0 THERMAL_NO_LIMITS THERMAL_NO_LIMITS>;
> +				    <&cpu0 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>;
>  			};
>  		};
>  	};
> @@ -298,13 +298,13 @@ used to monitor the zone 'cpu-thermal' using its sole sensor. A fan
>  device (fan0) is controlled via I2C bus 1, at address 0x48, and has ten
>  different cooling states 0-9. It is used to remove the heat out of
>  the thermal zone 'cpu-thermal' using its cooling states
> -from its minimum to 4, when it reaches trip point 'cpu-alert0'
> +from its minimum to 4, when it reaches trip point 'cpu_alert0'
>  at 90C, as an example of active cooling. The same cooling device is used at
> -'cpu-alert1', but from 5 to its maximum state. The cpu@0 device is also
> +'cpu_alert1', but from 5 to its maximum state. The cpu@0 device is also
>  linked to the same thermal zone, 'cpu-thermal', as a passive cooling device,
> -using all its cooling states at trip point 'cpu-alert1',
> +using all its cooling states at trip point 'cpu_alert1',
>  which is a trip point at 100C. On the thermal zone 'cpu-thermal', at the
> -temperature of 125C, represented by the trip point 'cpu-crit', the silicon
> +temperature of 125C, represented by the trip point 'cpu_crit', the silicon
>  is not reliable anymore.
>  
>  (b) - IC with several internal sensors
> @@ -329,7 +329,7 @@ ocp {
>  };
>  
>  thermal-zones {
> -	cpu-thermal: cpu-thermal {
> +	cpu_thermal: cpu-thermal {
>  		polling-delay-passive = <250>; /* milliseconds */
>  		polling-delay = <1000>; /* milliseconds */
>  
> @@ -338,12 +338,12 @@ thermal-zones {
>  
>  		trips {
>  			/* each zone within the SoC may have its own trips */
> -			cpu-alert: cpu-alert {
> +			cpu_alert: cpu-alert {
>  				temperature = <100000>; /* millicelsius */
>  				hysteresis = <2000>; /* millicelsius */
>  				type = "passive";
>  			};
> -			cpu-crit: cpu-crit {
> +			cpu_crit: cpu-crit {
>  				temperature = <125000>; /* millicelsius */
>  				hysteresis = <2000>; /* millicelsius */
>  				type = "critical";
> @@ -356,7 +356,7 @@ thermal-zones {
>  		};
>  	};
>  
> -	gpu-thermal: gpu-thermal {
> +	gpu_thermal: gpu-thermal {
>  		polling-delay-passive = <120>; /* milliseconds */
>  		polling-delay = <1000>; /* milliseconds */
>  
> @@ -365,12 +365,12 @@ thermal-zones {
>  
>  		trips {
>  			/* each zone within the SoC may have its own trips */
> -			gpu-alert: gpu-alert {
> +			gpu_alert: gpu-alert {
>  				temperature = <90000>; /* millicelsius */
>  				hysteresis = <2000>; /* millicelsius */
>  				type = "passive";
>  			};
> -			gpu-crit: gpu-crit {
> +			gpu_crit: gpu-crit {
>  				temperature = <105000>; /* millicelsius */
>  				hysteresis = <2000>; /* millicelsius */
>  				type = "critical";
> @@ -383,7 +383,7 @@ thermal-zones {
>  		};
>  	};
>  
> -	dsp-thermal: dsp-thermal {
> +	dsp_thermal: dsp-thermal {
>  		polling-delay-passive = <50>; /* milliseconds */
>  		polling-delay = <1000>; /* milliseconds */
>  
> @@ -392,12 +392,12 @@ thermal-zones {
>  
>  		trips {
>  			/* each zone within the SoC may have its own trips */
> -			dsp-alert: gpu-alert {
> +			dsp_alert: dsp-alert {
>  				temperature = <90000>; /* millicelsius */
>  				hysteresis = <2000>; /* millicelsius */
>  				type = "passive";
>  			};
> -			dsp-crit: gpu-crit {
> +			dsp_crit: gpu-crit {
>  				temperature = <135000>; /* millicelsius */
>  				hysteresis = <2000>; /* millicelsius */
>  				type = "critical";
> @@ -457,7 +457,7 @@ ocp {
>  };
>  
>  thermal-zones {
> -	cpu-thermal: cpu-thermal {
> +	cpu_thermal: cpu-thermal {
>  		polling-delay-passive = <250>; /* milliseconds */
>  		polling-delay = <1000>; /* milliseconds */
>  
> @@ -508,7 +508,7 @@ with many sensors and many cooling devices.
>  	/*
>  	 * An IC with several temperature sensor.
>  	 */
> -	adc-dummy: sensor@0x50 {
> +	adc_dummy: sensor@0x50 {
>  		...
>  		#thermal-sensor-cells = <1>; /* sensor internal ID */
>  	};
> @@ -531,7 +531,7 @@ thermal-zones {
>  		};
>  	};
>  
> -	board-thermal: board-thermal {
> +	board_thermal: board-thermal {
>  		polling-delay-passive = <1000>; /* milliseconds */
>  		polling-delay = <2500>; /* milliseconds */
>  
> @@ -548,22 +548,22 @@ thermal-zones {
>  
>  		trips {
>  			/* Trips are based on resulting linear equation */
> -			cpu-trip: cpu-trip {
> +			cpu_trip: cpu-trip {
>  				temperature = <60000>; /* millicelsius */
>  				hysteresis = <2000>; /* millicelsius */
>  				type = "passive";
>  			};
> -			gpu-trip: gpu-trip {
> +			gpu_trip: gpu-trip {
>  				temperature = <55000>; /* millicelsius */
>  				hysteresis = <2000>; /* millicelsius */
>  				type = "passive";
>  			}
> -			lcd-trip: lcp-trip {
> +			lcd_trip: lcp-trip {
>  				temperature = <53000>; /* millicelsius */
>  				hysteresis = <2000>; /* millicelsius */
>  				type = "passive";
>  			};
> -			crit-trip: crit-trip {
> +			crit_trip: crit-trip {
>  				temperature = <68000>; /* millicelsius */
>  				hysteresis = <2000>; /* millicelsius */
>  				type = "critical";
> @@ -572,17 +572,17 @@ thermal-zones {
>  
>  		cooling-maps {
>  			map0 {
> -				trip = <&cpu-trip>;
> +				trip = <&cpu_trip>;
>  				cooling-device = <&cpu0 0 2>;
>  				contribution = <55>;
>  			};
>  			map1 {
> -				trip = <&gpu-trip>;
> +				trip = <&gpu_trip>;
>  				cooling-device = <&gpu0 0 2>;
>  				contribution = <20>;
>  			};
>  			map2 {
> -				trip = <&lcd-trip>;
> +				trip = <&lcd_trip>;
>  				cooling-device = <&lcd0 5 10>;
>  				contribution = <15>;
>  			};
> -- 
> 1.9.1
> 

[-- Attachment #2: Digital signature --]
[-- Type: application/pgp-signature, Size: 473 bytes --]

  reply	other threads:[~2015-01-28 17:29 UTC|newest]

Thread overview: 3+ messages / expand[flat|nested]  mbox.gz  Atom feed  top
2015-01-28 17:13 [PATCH v2] thermal: Fix examples in DT documentation Srinivas Kandagatla
2015-01-28 17:29 ` Eduardo Valentin [this message]
2015-01-28 17:40   ` Srinivas Kandagatla

Reply instructions:

You may reply publicly to this message via plain-text email
using any one of the following methods:

* Save the following mbox file, import it into your mail client,
  and reply-to-all from there: mbox

  Avoid top-posting and favor interleaved quoting:
  https://en.wikipedia.org/wiki/Posting_style#Interleaved_style

* Reply using the --to, --cc, and --in-reply-to
  switches of git-send-email(1):

  git send-email \
    --in-reply-to=20150128172929.GA27003@developer.hsd1.ca.comcast.net \
    --to=edubezval@gmail.com \
    --cc=devicetree@vger.kernel.org \
    --cc=linux-kernel@vger.kernel.org \
    --cc=linux-pm@vger.kernel.org \
    --cc=robh+dt@kernel.org \
    --cc=rui.zhang@intel.com \
    --cc=srinivas.kandagatla@linaro.org \
    /path/to/YOUR_REPLY

  https://kernel.org/pub/software/scm/git/docs/git-send-email.html

* If your mail client supports setting the In-Reply-To header