linux-pm.vger.kernel.org archive mirror
 help / color / mirror / Atom feed
From: Viresh Kumar <viresh.kumar@linaro.org>
To: Brendan Jackman <brendan.jackman@arm.com>
Cc: linux-pm@vger.kernel.org,
	Amit Daniel Kachhap <amit.kachhap@gmail.com>,
	Javi Merino <javi.merino@arm.com>
Subject: Re: [PATCH] thermal: cpu_cooling: Fix NULL dereference in cpufreq_state2power
Date: Thu, 18 Aug 2016 04:35:07 +0530	[thread overview]
Message-ID: <20160817230507.GC24396@ubuntu> (raw)
In-Reply-To: <20160817151459.10948-1-brendan.jackman@arm.com>

On 17-08-16, 16:14, Brendan Jackman wrote:
> Currently all CPU cooling devices share a
> `struct thermal_cooling_device_ops` instance. The thermal core uses the
> presence of functions in this struct to determine if a cooling device
> has a power model (see cdev_is_power_actor). cpu_cooling.c adds the
> power model functions to the shared struct when a device is registered
> with a power model.
> 
> Therefore, if a CPU cooling device is registered using
> [of_]cpufreq_power_cooling_register, _all_ devices will be determined to
> have a power model, including any registered with
> [of_]cpufreq_cooling_register. This can result in cpufreq_state2power
> being called on a device where dyn_power_table is NULL.
> 
> With this commit, instead of having a shared thermal_cooling_device_ops
> which is mutated, we have two versions: one with the power functions and
> one without.
> 
> Signed-off-by: Brendan Jackman <brendan.jackman@arm.com>
> Cc: Amit Daniel Kachhap <amit.kachhap@gmail.com>
> Cc: Viresh Kumar <viresh.kumar@linaro.org>
> Cc: Javi Merino <javi.merino@arm.com>
> 
> ---
>  drivers/thermal/cpu_cooling.c | 21 ++++++++++++++++-----
>  1 file changed, 16 insertions(+), 5 deletions(-)
> 
> diff --git a/drivers/thermal/cpu_cooling.c b/drivers/thermal/cpu_cooling.c
> index 3788ed7..a32b417 100644
> --- a/drivers/thermal/cpu_cooling.c
> +++ b/drivers/thermal/cpu_cooling.c
> @@ -740,12 +740,22 @@ static int cpufreq_power2state(struct thermal_cooling_device *cdev,
>  }
> 
>  /* Bind cpufreq callbacks to thermal cooling device ops */
> +
>  static struct thermal_cooling_device_ops cpufreq_cooling_ops = {
>  	.get_max_state = cpufreq_get_max_state,
>  	.get_cur_state = cpufreq_get_cur_state,
>  	.set_cur_state = cpufreq_set_cur_state,
>  };
> 
> +static struct thermal_cooling_device_ops cpufreq_power_cooling_ops = {
> +	.get_max_state		= cpufreq_get_max_state,
> +	.get_cur_state		= cpufreq_get_cur_state,
> +	.set_cur_state		= cpufreq_set_cur_state,
> +	.get_requested_power	= cpufreq_get_requested_power,
> +	.state2power		= cpufreq_state2power,
> +	.power2state		= cpufreq_power2state,
> +};
> +
>  /* Notifier for cpufreq policy change */
>  static struct notifier_block thermal_cpufreq_notifier_block = {
>  	.notifier_call = cpufreq_thermal_notifier,
> @@ -795,6 +805,7 @@ __cpufreq_cooling_register(struct device_node *np,
>  	struct cpumask temp_mask;
>  	unsigned int freq, i, num_cpus;
>  	int ret;
> +	struct thermal_cooling_device_ops *cooling_ops;
> 
>  	cpumask_and(&temp_mask, clip_cpus, cpu_online_mask);
>  	policy = cpufreq_cpu_get(cpumask_first(&temp_mask));
> @@ -850,10 +861,6 @@ __cpufreq_cooling_register(struct device_node *np,
>  	cpumask_copy(&cpufreq_dev->allowed_cpus, clip_cpus);
> 
>  	if (capacitance) {
> -		cpufreq_cooling_ops.get_requested_power =
> -			cpufreq_get_requested_power;
> -		cpufreq_cooling_ops.state2power = cpufreq_state2power;
> -		cpufreq_cooling_ops.power2state = cpufreq_power2state;
>  		cpufreq_dev->plat_get_static_power = plat_static_func;
> 
>  		ret = build_dyn_power_table(cpufreq_dev, capacitance);
> @@ -861,6 +868,10 @@ __cpufreq_cooling_register(struct device_node *np,
>  			cool_dev = ERR_PTR(ret);
>  			goto free_table;
>  		}
> +
> +		cooling_ops = &cpufreq_power_cooling_ops;
> +	} else {
> +		cooling_ops = &cpufreq_cooling_ops;
>  	}
> 
>  	ret = get_idr(&cpufreq_idr, &cpufreq_dev->id);
> @@ -885,7 +896,7 @@ __cpufreq_cooling_register(struct device_node *np,
>  		 cpufreq_dev->id);
> 
>  	cool_dev = thermal_of_cooling_device_register(np, dev_name, cpufreq_dev,
> -						      &cpufreq_cooling_ops);
> +						      cooling_ops);
>  	if (IS_ERR(cool_dev))
>  		goto remove_idr;

Acked-by: Viresh Kumar <viresh.kumar@linaro.org>

-- 
viresh

  reply	other threads:[~2016-08-17 23:05 UTC|newest]

Thread overview: 4+ messages / expand[flat|nested]  mbox.gz  Atom feed  top
2016-08-17 15:14 [PATCH] thermal: cpu_cooling: Fix NULL dereference in cpufreq_state2power Brendan Jackman
2016-08-17 23:05 ` Viresh Kumar [this message]
2016-08-18  9:30   ` Javi Merino
2016-08-19 13:19     ` Zhang Rui

Reply instructions:

You may reply publicly to this message via plain-text email
using any one of the following methods:

* Save the following mbox file, import it into your mail client,
  and reply-to-all from there: mbox

  Avoid top-posting and favor interleaved quoting:
  https://en.wikipedia.org/wiki/Posting_style#Interleaved_style

* Reply using the --to, --cc, and --in-reply-to
  switches of git-send-email(1):

  git send-email \
    --in-reply-to=20160817230507.GC24396@ubuntu \
    --to=viresh.kumar@linaro.org \
    --cc=amit.kachhap@gmail.com \
    --cc=brendan.jackman@arm.com \
    --cc=javi.merino@arm.com \
    --cc=linux-pm@vger.kernel.org \
    /path/to/YOUR_REPLY

  https://kernel.org/pub/software/scm/git/docs/git-send-email.html

* If your mail client supports setting the In-Reply-To header
  via mailto: links, try the mailto: link
Be sure your reply has a Subject: header at the top and a blank line before the message body.
This is a public inbox, see mirroring instructions
for how to clone and mirror all data and code used for this inbox;