From mboxrd@z Thu Jan 1 00:00:00 1970 Return-Path: X-Spam-Checker-Version: SpamAssassin 3.4.0 (2014-02-07) on aws-us-west-2-korg-lkml-1.web.codeaurora.org X-Spam-Level: X-Spam-Status: No, score=-8.8 required=3.0 tests=DKIM_SIGNED,DKIM_VALID, DKIM_VALID_AU,HEADER_FROM_DIFFERENT_DOMAINS,INCLUDES_PATCH,MAILING_LIST_MULTI, SIGNED_OFF_BY,SPF_HELO_NONE,SPF_PASS,URIBL_BLOCKED,USER_AGENT_GIT autolearn=unavailable autolearn_force=no version=3.4.0 Received: from mail.kernel.org (mail.kernel.org [198.145.29.99]) by smtp.lore.kernel.org (Postfix) with ESMTP id C8AD0C48BD4 for ; Tue, 25 Jun 2019 11:33:15 +0000 (UTC) Received: from vger.kernel.org (vger.kernel.org [209.132.180.67]) by mail.kernel.org (Postfix) with ESMTP id 8D2BE2168B for ; Tue, 25 Jun 2019 11:33:15 +0000 (UTC) Authentication-Results: mail.kernel.org; dkim=pass (2048-bit key) header.d=linaro.org header.i=@linaro.org header.b="Ehnr0Rmw" Received: (majordomo@vger.kernel.org) by vger.kernel.org via listexpand id S1730627AbfFYLdK (ORCPT ); Tue, 25 Jun 2019 07:33:10 -0400 Received: from mail-wm1-f67.google.com ([209.85.128.67]:54479 "EHLO mail-wm1-f67.google.com" rhost-flags-OK-OK-OK-OK) by vger.kernel.org with ESMTP id S1730844AbfFYLdI (ORCPT ); Tue, 25 Jun 2019 07:33:08 -0400 Received: by mail-wm1-f67.google.com with SMTP id g135so2430049wme.4 for ; Tue, 25 Jun 2019 04:33:06 -0700 (PDT) DKIM-Signature: v=1; a=rsa-sha256; c=relaxed/relaxed; d=linaro.org; s=google; h=from:to:cc:subject:date:message-id:in-reply-to:references; bh=1GRtxbvJ7zQMEAzf5USjpOzydVY/5kmGwkIlpaLrADw=; b=Ehnr0RmwjLMD+uPoNHV4VCT4BrNvFINrvm11Jwmp0X8vbmx+CNYN+Xzx2gu/xT8lpq 8aedQccZjAUzVVMTUpA2k7EY0zEoQiuPm3+MTjSSCmKUCD4qEZah+MCAkZR/lkTRJI8S qbsbqrNVmVADWjyODTHoz5RjwGacaOvrPpOG9n+D2mTLbfYQ+6cyWLYZ1IFurqUM8G8C QxbXLEpXQHL1AOl5edMeAfrg6YT3BRmCXl7xMkLLqi8CqiM/UM97yFjN2PyGg9ciwVU4 QcDd6ai+2zpnXnbhsqFUf9fFfPiyk2XA1hse2h4u2/A/9o0zmmOSN14PBIHatZNybjvJ Cfpw== X-Google-DKIM-Signature: v=1; a=rsa-sha256; c=relaxed/relaxed; d=1e100.net; s=20161025; h=x-gm-message-state:from:to:cc:subject:date:message-id:in-reply-to :references; bh=1GRtxbvJ7zQMEAzf5USjpOzydVY/5kmGwkIlpaLrADw=; b=jGMvKpstNSB7YUj7qhYt0L8w2aW0gkcetWmywb/qF7pvTwLrR5/YmJO4+jElfQVDxJ 0HlHgoBvL8r+DKhmY2OYd4PeEkdsGnNa+R7Um6DAVxJ5vOoSstB1NSKiyDkB99AL1xUg l0mZUiAJyXZpOPLl74rGlBqLKJdu5A8DagyNc590qUumYMpAwJvaStnJBpnpZhNmoMXW 2OIIWh8JKxOYz5sbCpYYzIPaxvr8buVFiTo4rA4kEt9ico+W44TDQKCkXErOVgCLcEw7 M+fC17hciMEFcXqyUgZZgk0n3GaF0IcMzOxspY1Iql2FHzxWuy1d/kebFFpMj5LuhZjt hSGw== X-Gm-Message-State: APjAAAVrjvQNZZAwyWCwUu6uvMCm+qFkr7ID5DIXYLJcAKVOMYx10/Kg mv2x0x25z1QJcXV5HG3kIkdm7A== X-Google-Smtp-Source: APXvYqyEyB2lNfbV8SJL0HSWaizGxaMKeN5Sw5X3E86zHZQ+GTc3cszJfeHxfYNey1cdGehMbHxjSg== X-Received: by 2002:a05:600c:28d:: with SMTP id 13mr19743593wmk.5.1561462385508; Tue, 25 Jun 2019 04:33:05 -0700 (PDT) Received: from clegane.local (191.184.66.86.rev.sfr.net. [86.66.184.191]) by smtp.gmail.com with ESMTPSA id j7sm19254284wru.54.2019.06.25.04.33.03 (version=TLS1_2 cipher=ECDHE-RSA-AES128-GCM-SHA256 bits=128/128); Tue, 25 Jun 2019 04:33:04 -0700 (PDT) From: Daniel Lezcano To: viresh.kumar@linaro.org Cc: rjw@rjwysocki.net, edubezval@gmail.com, linux-kernel@vger.kernel.org, Amit Daniel Kachhap , Javi Merino , Zhang Rui , Shawn Guo , Sascha Hauer , Pengutronix Kernel Team , Fabio Estevam , NXP Linux Team , Keerthy , linux-pm@vger.kernel.org (open list:THERMAL/CPU_COOLING), linux-arm-kernel@lists.infradead.org (moderated list:ARM/FREESCALE IMX / MXC ARM ARCHITECTURE), linux-omap@vger.kernel.org (open list:TI BANDGAP AND THERMAL DRIVER) Subject: [PATCH V3 3/3] thermal/drivers/cpu_cooling: cpufreq_cooling_register returns an int Date: Tue, 25 Jun 2019 13:32:43 +0200 Message-Id: <20190625113244.18146-3-daniel.lezcano@linaro.org> X-Mailer: git-send-email 2.17.1 In-Reply-To: <20190625113244.18146-1-daniel.lezcano@linaro.org> References: <20190625113244.18146-1-daniel.lezcano@linaro.org> Sender: linux-pm-owner@vger.kernel.org Precedence: bulk List-ID: X-Mailing-List: linux-pm@vger.kernel.org It looks like after the changes in the patch the only reason for returning (struct thermal_cooling_device *) from cpufreq_cooling_register() is error checking, but it would be much more straightforward to return int for this purpose. Moreover, that would prevent the callers of it from doing incorrect things with the returned pointers (like using it to unregister the cooling device). Replace the returned value an integer instead of a pointer to a thermal cooling device structure. Suggested-by: Rafael J. Wysocki Signed-off-by: Daniel Lezcano --- drivers/thermal/cpu_cooling.c | 63 +++++++++---------- drivers/thermal/imx_thermal.c | 6 +- .../ti-soc-thermal/ti-thermal-common.c | 7 +-- include/linux/cpu_cooling.h | 16 ++--- 4 files changed, 40 insertions(+), 52 deletions(-) diff --git a/drivers/thermal/cpu_cooling.c b/drivers/thermal/cpu_cooling.c index 007c7c6bf845..f5fa31a57658 100644 --- a/drivers/thermal/cpu_cooling.c +++ b/drivers/thermal/cpu_cooling.c @@ -530,13 +530,12 @@ static struct notifier_block thermal_cpufreq_notifier_block = { * cooling devices. It also gives the opportunity to link the cooling device * with a device tree node, in order to bind it via the thermal DT code. * - * Return: a valid struct thermal_cooling_device pointer on success, - * on failure, it returns a corresponding ERR_PTR(). + * Return: zero on success, less than zero corresponding to the + * negative error code. */ -static struct thermal_cooling_device * -__cpufreq_cooling_register(struct device_node *np, - struct cpufreq_policy *policy, - struct em_perf_domain *em) +static int __cpufreq_cooling_register(struct device_node *np, + struct cpufreq_policy *policy, + struct em_perf_domain *em) { struct thermal_cooling_device *cdev; struct cpufreq_cooling_device *cpufreq_cdev; @@ -548,19 +547,19 @@ __cpufreq_cooling_register(struct device_node *np, if (IS_ERR_OR_NULL(policy)) { pr_err("%s: cpufreq policy isn't valid: %p\n", __func__, policy); - return ERR_PTR(-EINVAL); + return -EINVAL; } i = cpufreq_table_count_valid_entries(policy); if (!i) { pr_debug("%s: CPUFreq table not found or has no valid entries\n", __func__); - return ERR_PTR(-ENODEV); + return -ENODEV; } cpufreq_cdev = kzalloc(sizeof(*cpufreq_cdev), GFP_KERNEL); if (!cpufreq_cdev) - return ERR_PTR(-ENOMEM); + return -ENOMEM; cpufreq_cdev->policy = policy; num_cpus = cpumask_weight(policy->related_cpus); @@ -568,7 +567,7 @@ __cpufreq_cooling_register(struct device_node *np, sizeof(*cpufreq_cdev->idle_time), GFP_KERNEL); if (!cpufreq_cdev->idle_time) { - cdev = ERR_PTR(-ENOMEM); + ret = -ENOMEM; goto free_cdev; } @@ -576,10 +575,8 @@ __cpufreq_cooling_register(struct device_node *np, cpufreq_cdev->max_level = i - 1; ret = ida_simple_get(&cpufreq_ida, 0, 0, GFP_KERNEL); - if (ret < 0) { - cdev = ERR_PTR(ret); + if (ret < 0) goto free_idle_time; - } cpufreq_cdev->id = ret; snprintf(dev_name, sizeof(dev_name), "thermal-cpufreq-%d", @@ -597,14 +594,16 @@ __cpufreq_cooling_register(struct device_node *np, if (policy->freq_table_sorted == CPUFREQ_TABLE_UNSORTED) { pr_err("%s: unsorted frequency tables are not supported\n", __func__); - cdev = ERR_PTR(-EINVAL); + ret = -EINVAL; goto remove_ida; } cdev = thermal_of_cooling_device_register(np, dev_name, cpufreq_cdev, cooling_ops); - if (IS_ERR(cdev)) + if (IS_ERR(cdev)) { + ret = PTR_ERR(cdev); goto remove_ida; + } cpufreq_cdev->clipped_freq = get_state_freq(cpufreq_cdev, 0); cpufreq_cdev->cdev = cdev; @@ -619,7 +618,7 @@ __cpufreq_cooling_register(struct device_node *np, cpufreq_register_notifier(&thermal_cpufreq_notifier_block, CPUFREQ_POLICY_NOTIFIER); - return cdev; + return 0; remove_ida: ida_simple_remove(&cpufreq_ida, cpufreq_cdev->id); @@ -627,7 +626,7 @@ __cpufreq_cooling_register(struct device_node *np, kfree(cpufreq_cdev->idle_time); free_cdev: kfree(cpufreq_cdev); - return cdev; + return ret; } /** @@ -638,11 +637,10 @@ __cpufreq_cooling_register(struct device_node *np, * "thermal-cpufreq-%x". This api can support multiple instances of cpufreq * cooling devices. * - * Return: a valid struct thermal_cooling_device pointer on success, - * on failure, it returns a corresponding ERR_PTR(). + * Return: zero on success, less than zero corresponding to the + * negative error code. */ -struct thermal_cooling_device * -cpufreq_cooling_register(struct cpufreq_policy *policy) +int cpufreq_cooling_register(struct cpufreq_policy *policy) { return __cpufreq_cooling_register(NULL, policy, NULL); } @@ -664,34 +662,31 @@ EXPORT_SYMBOL_GPL(cpufreq_cooling_register); * It also takes into account, if property present in policy CPU node, the * static power consumed by the cpu. * - * Return: a valid struct thermal_cooling_device pointer on success, - * and NULL on failure. + * Return: zero on success, less than zero corresponding to the + * negative error code. */ -struct thermal_cooling_device * -of_cpufreq_cooling_register(struct cpufreq_policy *policy) +int of_cpufreq_cooling_register(struct cpufreq_policy *policy) { struct device_node *np = of_get_cpu_node(policy->cpu, NULL); - struct thermal_cooling_device *cdev = NULL; + int ret = -EINVAL; if (!np) { pr_err("cpu_cooling: OF node not available for cpu%d\n", policy->cpu); - return NULL; + return -EINVAL; } if (of_find_property(np, "#cooling-cells", NULL)) { struct em_perf_domain *em = em_cpu_get(policy->cpu); - cdev = __cpufreq_cooling_register(np, policy, em); - if (IS_ERR(cdev)) { - pr_err("cpu_cooling: cpu%d failed to register as cooling device: %ld\n", - policy->cpu, PTR_ERR(cdev)); - cdev = NULL; - } + ret = __cpufreq_cooling_register(np, policy, em); + if (ret) + pr_err("cpu_cooling: cpu%d failed to register as cooling device: %d\n", + policy->cpu, ret); } of_node_put(np); - return cdev; + return ret; } EXPORT_SYMBOL_GPL(of_cpufreq_cooling_register); diff --git a/drivers/thermal/imx_thermal.c b/drivers/thermal/imx_thermal.c index 021c0948b740..1c4b49b583bc 100644 --- a/drivers/thermal/imx_thermal.c +++ b/drivers/thermal/imx_thermal.c @@ -655,7 +655,6 @@ MODULE_DEVICE_TABLE(of, of_imx_thermal_match); static int imx_thermal_register_legacy_cooling(struct imx_thermal_data *data) { struct device_node *np; - struct thermal_cooling_device *cdev; int ret; data->policy = cpufreq_cpu_get(0); @@ -667,9 +666,8 @@ static int imx_thermal_register_legacy_cooling(struct imx_thermal_data *data) np = of_get_cpu_node(data->policy->cpu, NULL); if (!np || !of_find_property(np, "#cooling-cells", NULL)) { - cdev = cpufreq_cooling_register(data->policy); - if (IS_ERR(cdev)) { - ret = PTR_ERR(cdev); + ret = cpufreq_cooling_register(data->policy); + if (ret) { cpufreq_cpu_put(data->policy); return ret; } diff --git a/drivers/thermal/ti-soc-thermal/ti-thermal-common.c b/drivers/thermal/ti-soc-thermal/ti-thermal-common.c index 170b70b6ec61..eacc46d7bd1c 100644 --- a/drivers/thermal/ti-soc-thermal/ti-thermal-common.c +++ b/drivers/thermal/ti-soc-thermal/ti-thermal-common.c @@ -232,7 +232,7 @@ int ti_thermal_register_cpu_cooling(struct ti_bandgap *bgp, int id) { struct ti_thermal_data *data; struct device_node *np = bgp->dev->of_node; - struct thermal_cooling_device *cdev; + int ret; /* * We are assuming here that if one deploys the zone @@ -256,9 +256,8 @@ int ti_thermal_register_cpu_cooling(struct ti_bandgap *bgp, int id) } /* Register cooling device */ - cdev = cpufreq_cooling_register(data->policy); - if (IS_ERR(cdev)) { - int ret = PTR_ERR(cdev); + ret = cpufreq_cooling_register(data->policy); + if (ret) { dev_err(bgp->dev, "Failed to register cpu cooling device %d\n", ret); cpufreq_cpu_put(data->policy); diff --git a/include/linux/cpu_cooling.h b/include/linux/cpu_cooling.h index 89f469ee4be4..98f7c8a9cab6 100644 --- a/include/linux/cpu_cooling.h +++ b/include/linux/cpu_cooling.h @@ -24,8 +24,7 @@ struct cpufreq_policy; * cpufreq_cooling_register - function to create cpufreq cooling device. * @policy: cpufreq policy. */ -struct thermal_cooling_device * -cpufreq_cooling_register(struct cpufreq_policy *policy); +int cpufreq_cooling_register(struct cpufreq_policy *policy); /** * cpufreq_cooling_unregister - function to remove cpufreq cooling device. @@ -34,10 +33,9 @@ cpufreq_cooling_register(struct cpufreq_policy *policy); void cpufreq_cooling_unregister(struct cpufreq_policy *policy); #else /* !CONFIG_CPU_THERMAL */ -static inline struct thermal_cooling_device * -cpufreq_cooling_register(struct cpufreq_policy *policy) +static inline int cpufreq_cooling_register(struct cpufreq_policy *policy) { - return ERR_PTR(-ENOSYS); + return -ENOSYS; } static inline @@ -52,13 +50,11 @@ void cpufreq_cooling_unregister(struct cpufreq_policy *policy) * of_cpufreq_cooling_register - create cpufreq cooling device based on DT. * @policy: cpufreq policy. */ -struct thermal_cooling_device * -of_cpufreq_cooling_register(struct cpufreq_policy *policy); +int of_cpufreq_cooling_register(struct cpufreq_policy *policy); #else -static inline struct thermal_cooling_device * -of_cpufreq_cooling_register(struct cpufreq_policy *policy) +static inline int of_cpufreq_cooling_register(struct cpufreq_policy *policy) { - return NULL; + return -ENOSYS; } #endif /* defined(CONFIG_THERMAL_OF) && defined(CONFIG_CPU_THERMAL) */ -- 2.17.1