From mboxrd@z Thu Jan 1 00:00:00 1970 From: Roman Mamedov Subject: Re: RAID5 member disks shrunk Date: Thu, 3 Jan 2013 21:42:36 +0600 Message-ID: <20130103214236.3fe60580@natsu> References: Mime-Version: 1.0 Content-Type: multipart/signed; micalg=PGP-SHA1; boundary="Sig_/clP6C2P3EW2ijbU0n+.ILu1"; protocol="application/pgp-signature" Return-path: In-Reply-To: Sender: linux-raid-owner@vger.kernel.org To: Alex Leach Cc: linux-raid@vger.kernel.org List-Id: linux-raid.ids --Sig_/clP6C2P3EW2ijbU0n+.ILu1 Content-Type: text/plain; charset=US-ASCII Content-Transfer-Encoding: quoted-printable On Thu, 03 Jan 2013 15:33:55 -0000 "Alex Leach" wrote: > 9. Putting it back together, I accidentally connected one of the good = =20 > RAID member drives to the SAS controller, and the SAS drive into one of = =20 > the SATA ports, which has an Intel ICH10R controller. Try checking if your controller/BIOS have shrunk the disk by establishing an HPA on it, the easiest way to check if you have any is perhaps with=20 dmesg | grep HPA If that is indeed the case, you can control it with "hdparm -N" (see its ma= n page). --=20 With respect, Roman ~~~~~~~~~~~~~~~~~~~~~~~~~~~ "Stallman had a printer, with code he could not see. So he began to tinker, and set the software free." --Sig_/clP6C2P3EW2ijbU0n+.ILu1 Content-Type: application/pgp-signature; name=signature.asc Content-Disposition: attachment; filename=signature.asc -----BEGIN PGP SIGNATURE----- Version: GnuPG v1.4.12 (GNU/Linux) iEYEARECAAYFAlDlpuwACgkQTLKSvz+PZwjk1QCfXQ5VOUqpDKYKe0uro3adW1mN nyQAnjoiu3vt5yyeAxn+bHcf248mXeMP =g56N -----END PGP SIGNATURE----- --Sig_/clP6C2P3EW2ijbU0n+.ILu1--