* IB errors with openMPI
@ 2010-02-22 5:46 Pradeep Satyanarayana
0 siblings, 0 replies; only message in thread
From: Pradeep Satyanarayana @ 2010-02-22 5:46 UTC (permalink / raw)
To: EWG; +Cc: linux-rdma
We are trying run openMPI with OFED-1.5 on the 2.6.31-rt11-preempt-rt kernel and see the following errors:
[[45393,1],8][../../../../../ompi/mca/btl/openib/btl_openib_component.c:2951:handle_wc]
from elm3b107 to: elm3b17 error polling HP CQ with status WORK REQUEST FLUSHED
ERROR status number 5 for wr_id 1289846528 opcode -1782678528 vendor error 244
qp_idx 0
At this point I looked at the mlx4 diag counters and saw some non-zero values. Since we were attempting
a series of runs, we don't know when the counters increased from 0. Do these counters have any correlation
to the above MPI error?
[root@elm3b17 diag_counters]# pwd
/sys/class/infiniband/mlx4_0/diag_counters
[root@elm3b17 diag_counters]#
[root@elm3b17 diag_counters]# cat rq_num_rnr
19
[root@elm3b17 diag_counters]# cat rq_num_wrfe
2009
[root@elm3b17 diag_counters]# cat sq_num_tree
12
[root@elm3b17 diag_counters]# cat sq_num_wrfe
12
[root@elm3b17 diag_counters]#
Similarly on 3b107 let us look at the counters.
[root@elm3b107 diag_counters]# cat rq_num_wrfe
5156
[root@elm3b107 diag_counters]# cat sq_num_rnr
18
[root@elm3b107 diag_counters]# cat sq_num_tree
20
[root@elm3b107 diag_counters]# cat sq_num_wrfe
20
[root@elm3b107 diag_counters]#
We are using ConnectX dual port DDR HCAs (FW version 2.6). What does the vendor error 244 mean? Any suggestions to
debug this further?
Thanks
Pradeep
^ permalink raw reply [flat|nested] only message in thread
only message in thread, other threads:[~2010-02-22 5:46 UTC | newest]
Thread overview: (only message) (download: mbox.gz follow: Atom feed
-- links below jump to the message on this page --
2010-02-22 5:46 IB errors with openMPI Pradeep Satyanarayana
This is a public inbox, see mirroring instructions
for how to clone and mirror all data and code used for this inbox