* CentOS 6.5 tgtadm LUN ID set doesn't work
@ 2014-09-16 19:30 Gonçalo Rosa
0 siblings, 0 replies; 2+ messages in thread
From: Gonçalo Rosa @ 2014-09-16 19:30 UTC (permalink / raw)
To: linux-scsi
Hello,
I did the following procedure:
tgtadm lld iscsi mode target op new tid 1 targetname
iqn.2014-09.local.vclass:tg0
tgtadm lld iscsi op new mode logicalunit tid 1 lun 1 backing-store
/dev/sdg
tgtadm lld iscsi op new mode logicalunit tid 1 lun 2 backing-store
/dev/sdh
tgtadm lld iscsi op new mode logicalunit tid 1 lun 3 backing-store
/dev/sdi
tgtadm lld iscsi op new mode logicalunit tid 1 lun 4 backing-store
/dev/sdj
tgtadm lld iscsi mode target op new tid 2 targetname
iqn.2014-09.local.vclass:tg1
tgtadm lld iscsi mode target op new tid 3 targetname
iqn.2014-09.local.vclass:tg2
tgtadm lld iscsi op new mode logicalunit tid 2 lun 5 backing-store
/dev/sde
tgtadm lld iscsi op new mode logicalunit tid 3 lun 5 backing-store
/dev/sdf
tgtadm lld iscsi op bind mode target tid 2 initiator-address
172.20.10.61
tgtadm lld iscsi op bind mode target tid 3 initiator-address
172.20.10.62
tgtadm mode target op show
tgt-admin dump > /etc/tgt/targets.conf
and the tgtadm mode target op show output was as shown bellow:
[root@iscsi ~]# tgtadm mode target op show
Target 1: iqn.2014-09.local.vclass:tg0
System information:
Driver: iscsi
State: ready
I_T nexus information:
LUN information:
LUN: 0
Type: controller
SCSI ID: IET 00010000
SCSI SN: beaf10
Size: 0 MB, Block size: 1
Online: Yes
Removable media: No
Prevent removal: No
Readonly: No
Backing store type: null
Backing store path: None
Backing store flags:
LUN: 1
Type: disk
SCSI ID: IET 00010001
SCSI SN: beaf11
Size: 10737 MB, Block size: 512
Online: Yes
Removable media: No
Prevent removal: No
Readonly: No
Backing store type: rdwr
Backing store path: /dev/sdg
Backing store flags:
LUN: 2
Type: disk
SCSI ID: IET 00010002
SCSI SN: beaf12
Size: 10737 MB, Block size: 512
Online: Yes
Removable media: No
Prevent removal: No
Readonly: No
Backing store type: rdwr
Backing store path: /dev/sdh
Backing store flags:
LUN: 3
Type: disk
SCSI ID: IET 00010003
SCSI SN: beaf13
Size: 10737 MB, Block size: 512
Online: Yes
Removable media: No
Prevent removal: No
Readonly: No
Backing store type: rdwr
Backing store path: /dev/sdi
Backing store flags:
LUN: 4
Type: disk
SCSI ID: IET 00010004
SCSI SN: beaf14
Size: 10737 MB, Block size: 512
Online: Yes
Removable media: No
Prevent removal: No
Readonly: No
Backing store type: rdwr
Backing store path: /dev/sdj
Backing store flags:
Account information:
ACL information:
Target 2: iqn.2014-09.local.vclass:tg1
System information:
Driver: iscsi
State: ready
I_T nexus information:
LUN information:
LUN: 0
Type: controller
SCSI ID: IET 00020000
SCSI SN: beaf20
Size: 0 MB, Block size: 1
Online: Yes
Removable media: No
Prevent removal: No
Readonly: No
Backing store type: null
Backing store path: None
Backing store flags:
LUN: 5
Type: disk
SCSI ID: IET 00020005
SCSI SN: beaf25
Size: 10737 MB, Block size: 512
Online: Yes
Removable media: No
Prevent removal: No
Readonly: No
Backing store type: rdwr
Backing store path: /dev/sde
Backing store flags:
Account information:
ACL information:
172.20.10.61
Target 3: iqn.2014-09.local.vclass:tg2
System information:
Driver: iscsi
State: ready
I_T nexus information:
LUN information:
LUN: 0
Type: controller
SCSI ID: IET 00030000
SCSI SN: beaf30
Size: 0 MB, Block size: 1
Online: Yes
Removable media: No
Prevent removal: No
Readonly: No
Backing store type: null
Backing store path: None
Backing store flags:
LUN: 5
Type: disk
SCSI ID: IET 00030005
SCSI SN: beaf35
Size: 10737 MB, Block size: 512
Online: Yes
Removable media: No
Prevent removal: No
Readonly: No
Backing store type: rdwr
Backing store path: /dev/sdf
Backing store flags:
Account information:
ACL information:
172.20.10.62
My intention is that all LUN IDs should be different per host, so tg0 will
serves shared LUNs 1,2,3 and 4 and tg1 serves LUN 5 to host 172.20.10.61 and
tg2 serves LUN 5 to host 172.20.10.62. I am using CentOS 6.5
After reboot tg1 and tg2 presents the LUNs both with LUN ID 1.
Also added LUN 5 to both targets in /etc/tgt/targets.conf and after reboot
ignores the instruction and still presents with LUN ID 1.
/etc/tgt/targets.conf bellow:
Default-driver iscsi
backing-store /dev/sdf
LUN 5
initiator-address 172.20.10.62
backing-store /dev/sde
LUN 5
initiator-address 172.20.10.61
backing-store /dev/sdg
backing-store /dev/sdh
backing-store /dev/sdi
backing-store /dev/sdj
Please, can anyone be so kind and help me to fix the LUN IDs?
Thank you in advance.
--
To unsubscribe from this list: send the line "unsubscribe linux-scsi" in
the body of a message to majordomo@vger.kernel.org
More majordomo info at http://vger.kernel.org/majordomo-info.html
^ permalink raw reply [flat|nested] 2+ messages in thread
* RE: CentOS 6.5 tgtadm LUN ID set doesn't work
@ 2014-09-17 18:51 Gonçalo Rosa
0 siblings, 0 replies; 2+ messages in thread
From: Gonçalo Rosa @ 2014-09-17 18:51 UTC (permalink / raw)
To: linux-scsi; +Cc: linux-scsi-owner
Hello,
I am having issues to have tgtd to assume specified LUN ID numbers.
I did the following procedure:
tgtadm --lld iscsi --mode target --op new --tid 1 --targetname
iqn.2014-09.local.vclass:tg0
tgtadm --lld iscsi --op new --mode logicalunit --tid 1 --lun 1
--backing-store /dev/sdg
tgtadm --lld iscsi --op new --mode logicalunit --tid 1 --lun 2
--backing-store /dev/sdh
tgtadm --lld iscsi --op new --mode logicalunit --tid 1 --lun 3
--backing-store /dev/sdi
tgtadm --lld iscsi --op new --mode logicalunit --tid 1 --lun 4
--backing-store /dev/sdj
tgtadm --lld iscsi --mode target --op new --tid 2 --targetname
iqn.2014-09.local.vclass:tg1
tgtadm --lld iscsi --mode target --op new --tid 3 --targetname
iqn.2014-09.local.vclass:tg2
tgtadm --lld iscsi --op new --mode logicalunit --tid 2 --lun 5
--backing-store /dev/sde
tgtadm --lld iscsi --op new --mode logicalunit --tid 3 --lun 5
--backing-store /dev/sdf
tgtadm --lld iscsi --op bind --mode target --tid 2 --initiator-address
172.20.10.61
tgtadm --lld iscsi --op bind --mode target --tid 3 --initiator-address
172.20.10.62
tgtadm --mode target --op show
tgt-admin --dump > /etc/tgt/targets.conf
and the tgtadm --mode target --op show output was as shown below:
[root@iscsi ~]# tgtadm --mode target --op show
Target 1: iqn.2014-09.local.vclass:tg0
System information:
Driver: iscsi
State: ready
I_T nexus information:
LUN information:
LUN: 0
Type: controller
SCSI ID: IET 00010000
SCSI SN: beaf10
Size: 0 MB, Block size: 1
Online: Yes
Removable media: No
Prevent removal: No
Readonly: No
Backing store type: null
Backing store path: None
Backing store flags:
LUN: 1
Type: disk
SCSI ID: IET 00010001
SCSI SN: beaf11
Size: 10737 MB, Block size: 512
Online: Yes
Removable media: No
Prevent removal: No
Readonly: No
Backing store type: rdwr
Backing store path: /dev/sdg
Backing store flags:
LUN: 2
Type: disk
SCSI ID: IET 00010002
SCSI SN: beaf12
Size: 10737 MB, Block size: 512
Online: Yes
Removable media: No
Prevent removal: No
Readonly: No
Backing store type: rdwr
Backing store path: /dev/sdh
Backing store flags:
LUN: 3
Type: disk
SCSI ID: IET 00010003
SCSI SN: beaf13
Size: 10737 MB, Block size: 512
Online: Yes
Removable media: No
Prevent removal: No
Readonly: No
Backing store type: rdwr
Backing store path: /dev/sdi
Backing store flags:
LUN: 4
Type: disk
SCSI ID: IET 00010004
SCSI SN: beaf14
Size: 10737 MB, Block size: 512
Online: Yes
Removable media: No
Prevent removal: No
Readonly: No
Backing store type: rdwr
Backing store path: /dev/sdj
Backing store flags:
Account information:
ACL information:
Target 2: iqn.2014-09.local.vclass:tg1
System information:
Driver: iscsi
State: ready
I_T nexus information:
LUN information:
LUN: 0
Type: controller
SCSI ID: IET 00020000
SCSI SN: beaf20
Size: 0 MB, Block size: 1
Online: Yes
Removable media: No
Prevent removal: No
Readonly: No
Backing store type: null
Backing store path: None
Backing store flags:
LUN: 5
Type: disk
SCSI ID: IET 00020005
SCSI SN: beaf25
Size: 10737 MB, Block size: 512
Online: Yes
Removable media: No
Prevent removal: No
Readonly: No
Backing store type: rdwr
Backing store path: /dev/sde
Backing store flags:
Account information:
ACL information:
172.20.10.61
Target 3: iqn.2014-09.local.vclass:tg2
System information:
Driver: iscsi
State: ready
I_T nexus information:
LUN information:
LUN: 0
Type: controller
SCSI ID: IET 00030000
SCSI SN: beaf30
Size: 0 MB, Block size: 1
Online: Yes
Removable media: No
Prevent removal: No
Readonly: No
Backing store type: null
Backing store path: None
Backing store flags:
LUN: 5
Type: disk
SCSI ID: IET 00030005
SCSI SN: beaf35
Size: 10737 MB, Block size: 512
Online: Yes
Removable media: No
Prevent removal: No
Readonly: No
Backing store type: rdwr
Backing store path: /dev/sdf
Backing store flags:
Account information:
ACL information:
172.20.10.62
My intention is that all LUN IDs should be different per host, so tg0 will
serves shared LUNs 1,2,3 and 4 and tg1 serves LUN 5 to host 172.20.10.61 and
tg2 serves LUN 5 to host 172.20.10.62. I am using CentOS 6.5
After reboot tg1 and tg2 presents the LUNs both with LUN ID 1.
Also added LUN 5 to both targets in /etc/tgt/targets.conf and after reboot
ignores the instruction and still presents with LUN ID 1.
/etc/tgt/targets.conf below:
Default-driver iscsi
backing-store /dev/sdf
LUN 5
initiator-address 172.20.10.62
backing-store /dev/sde
LUN 5
initiator-address 172.20.10.61
backing-store /dev/sdg
backing-store /dev/sdh
backing-store /dev/sdi
backing-store /dev/sdj
Please, can anyone be so kind and help me to fix the LUN IDs?
Thank you in advance.
^ permalink raw reply [flat|nested] 2+ messages in thread
end of thread, other threads:[~2014-09-17 18:51 UTC | newest]
Thread overview: 2+ messages (download: mbox.gz follow: Atom feed
-- links below jump to the message on this page --
2014-09-17 18:51 CentOS 6.5 tgtadm LUN ID set doesn't work Gonçalo Rosa
-- strict thread matches above, loose matches on Subject: below --
2014-09-16 19:30 Gonçalo Rosa
This is a public inbox, see mirroring instructions
for how to clone and mirror all data and code used for this inbox