From mboxrd@z Thu Jan 1 00:00:00 1970 From: Vince Hsu Subject: Re: [PATCH 1/11] ARM: tegra: add function to control the GPU rail clamp Date: Wed, 7 Jan 2015 22:28:29 +0800 Message-ID: <20150107142828.GB7392@nvidia.com> References: <1419331204-26679-1-git-send-email-vinceh@nvidia.com> <1419331204-26679-2-git-send-email-vinceh@nvidia.com> <1419426990.2179.7.camel@lynxeye.de> <549B7638.2010405@nvidia.com> <20150105150932.GG12010@ulmo.nvidia.com> <20150107101900.GP10073@tbergstrom-lnx.Nvidia.com> <54AD0F37.5080609@nvidia.com> <20150107132709.GA6988@ulmo> <20150107140852.GR10073@tbergstrom-lnx.Nvidia.com> Mime-Version: 1.0 Content-Type: text/plain; charset="us-ascii" Return-path: In-Reply-To: <20150107140852.GR10073@tbergstrom-lnx.Nvidia.com> Content-Disposition: inline Sender: linux-kernel-owner@vger.kernel.org To: Peter De Schrijver Cc: Thierry Reding , Lucas Stach , swarren@wwwdotorg.org, gnurou@gmail.com, bskeggs@redhat.com, martin.peres@free.fr, seven@nimrod-online.com, samuel.pitoiset@gmail.com, nouveau@lists.freedesktop.org, linux-tegra@vger.kernel.org, linux-kernel@vger.kernel.org List-Id: linux-tegra@vger.kernel.org On 04:08:52PM Jan 07, Peter De Schrijver wrote: > On Wed, Jan 07, 2015 at 02:27:10PM +0100, Thierry Reding wrote: > > > > Yeah. I plan to have the information of all the clock client of the > > > partitions and > > > the memory clients be defined statically in c source, e.g. pmc-tegra124.c. > > > All modules can declare which domain they belong to in DT. One domain can > > > be really power gated only when no module is awake. Note the clock clients > > > of > > > one domain might not equal to the clocks of the module. The reset is not > > > either. > > > So I don't get the clock and reset from module. How do you think? > > > > This whole situation is quite messy. The above sequence basically means > > that drivers can't reset hardware modules because otherwise they might > > race with the power domain code. It also means that we can't powergate > > The powerdomain framework won't call any powergating method as long as a > module in the domain is still active. So as long as drivers don't try to > reset the hw without having done a pm_runtime_get(), we shouldn't have such > a race? Agree. And as long as the driver has the correct reset procedure, that should be fine to occur between power ungating and gating sequences. > > > modules on demand because they might be in the same power domain as one > > other module that's still busy. > > > > The powerdomain framework keeps track of which modules are active (by hooking > into runtime pm) and won't try to shutdown a domain unless all modules are > inactive. Yeah. By the way, that means we should start supporting runtime pm for all the modules to use generic power domain. Thanks, Vince > > > How would we handle a situation where a hardware module hangs and we can > > only get it back via a reset? > > > > Cheers, > > Peter.