From mboxrd@z Thu Jan 1 00:00:00 1970 Return-Path: Received: from mail.lixom.net (lixom.net [66.141.50.11]) by ozlabs.org (Postfix) with ESMTP id DBD78DDDF8 for ; Mon, 24 Dec 2007 15:02:19 +1100 (EST) Date: Sun, 23 Dec 2007 22:09:15 -0600 From: Olof Johansson To: ramkumarj Ramkumar Subject: Re: Loop at starting pid 164, tty '': '/sbin/getty' Message-ID: <20071224040915.GA20380@lixom.net> References: <4f8c3030712220051if731af9g350af9d45a75c244@mail.gmail.com> MIME-Version: 1.0 Content-Type: text/plain; charset=us-ascii In-Reply-To: <4f8c3030712220051if731af9g350af9d45a75c244@mail.gmail.com> Cc: linuxppc-embedded@ozlabs.org List-Id: Linux on Embedded PowerPC Developers Mail List List-Unsubscribe: , List-Archive: List-Post: List-Help: List-Subscribe: , Hi, On Sat, Dec 22, 2007 at 04:51:16PM +0800, ramkumarj Ramkumar wrote: > I m trying to run Linux 2.6 ( From Grant) on ML-403. I used the > busybox-1.7.2. During booting, I found the following logs and it keeps > trying to respawn the getty.It keeps looping and I never see the login > prompt. Am I missing something. > > process '/sbin/getty 38400 tts/0' (pid 163) exited. Scheduling it for > restart. Do you have a /dev/ttys/0? First serial port is normally /dev/ttyS0. -Olof