From: "Cédric Le Goater" <clg@kaod.org>
To: Michael Ellerman <mpe@ellerman.id.au>
Cc: kvm@vger.kernel.org, "Nicholas Piggin" <npiggin@gmail.com>,
kvm-ppc@vger.kernel.org, "Paul Mackerras" <paulus@samba.org>,
"Cédric Le Goater" <clg@kaod.org>,
linuxppc-dev@lists.ozlabs.org
Subject: [PATCH] KVM: PPC: Book3S HV: increase KVMPPC_NR_LPIDS on POWER8 and POWER9
Date: Mon, 8 Jun 2020 13:57:14 +0200 [thread overview]
Message-ID: <20200608115714.1139735-1-clg@kaod.org> (raw)
POWER8 and POWER9 have 12-bit LPIDs. Change LPID_RSVD to support up to
(4096 - 2) guests on these processors. POWER7 is kept the same with a
limitation of (1024 - 2), but it might be time to drop KVM support for
POWER7.
Tested with 2048 guests * 4 vCPUs on a witherspoon system with 512G
RAM and a bit of swap.
Signed-off-by: Cédric Le Goater <clg@kaod.org>
---
arch/powerpc/include/asm/reg.h | 3 ++-
arch/powerpc/kvm/book3s_64_mmu_hv.c | 8 ++++++--
2 files changed, 8 insertions(+), 3 deletions(-)
diff --git a/arch/powerpc/include/asm/reg.h b/arch/powerpc/include/asm/reg.h
index 88e6c78100d9..b70bbfb0ea3c 100644
--- a/arch/powerpc/include/asm/reg.h
+++ b/arch/powerpc/include/asm/reg.h
@@ -473,7 +473,8 @@
#ifndef SPRN_LPID
#define SPRN_LPID 0x13F /* Logical Partition Identifier */
#endif
-#define LPID_RSVD 0x3ff /* Reserved LPID for partn switching */
+#define LPID_RSVD_POWER7 0x3ff /* Reserved LPID for partn switching */
+#define LPID_RSVD 0xfff /* Reserved LPID for partn switching */
#define SPRN_HMER 0x150 /* Hypervisor maintenance exception reg */
#define HMER_DEBUG_TRIG (1ul << (63 - 17)) /* Debug trigger */
#define SPRN_HMEER 0x151 /* Hyp maintenance exception enable reg */
diff --git a/arch/powerpc/kvm/book3s_64_mmu_hv.c b/arch/powerpc/kvm/book3s_64_mmu_hv.c
index 18aed9775a3c..23035ab2ec50 100644
--- a/arch/powerpc/kvm/book3s_64_mmu_hv.c
+++ b/arch/powerpc/kvm/book3s_64_mmu_hv.c
@@ -260,11 +260,15 @@ int kvmppc_mmu_hv_init(void)
if (!mmu_has_feature(MMU_FTR_LOCKLESS_TLBIE))
return -EINVAL;
- /* POWER7 has 10-bit LPIDs (12-bit in POWER8) */
host_lpid = 0;
if (cpu_has_feature(CPU_FTR_HVMODE))
host_lpid = mfspr(SPRN_LPID);
- rsvd_lpid = LPID_RSVD;
+
+ /* POWER8 and above have 12-bit LPIDs (10-bit in POWER7) */
+ if (cpu_has_feature(CPU_FTR_ARCH_207S))
+ rsvd_lpid = LPID_RSVD;
+ else
+ rsvd_lpid = LPID_RSVD_POWER7;
kvmppc_init_lpid(rsvd_lpid + 1);
--
2.25.4
next reply other threads:[~2020-06-08 12:38 UTC|newest]
Thread overview: 4+ messages / expand[flat|nested] mbox.gz Atom feed top
2020-06-08 11:57 Cédric Le Goater [this message]
2020-06-23 15:08 ` [PATCH] KVM: PPC: Book3S HV: increase KVMPPC_NR_LPIDS on POWER8 and POWER9 Cédric Le Goater
2020-07-23 6:20 ` Paul Mackerras
2020-07-27 9:38 ` Cédric Le Goater
Reply instructions:
You may reply publicly to this message via plain-text email
using any one of the following methods:
* Save the following mbox file, import it into your mail client,
and reply-to-all from there: mbox
Avoid top-posting and favor interleaved quoting:
https://en.wikipedia.org/wiki/Posting_style#Interleaved_style
* Reply using the --to, --cc, and --in-reply-to
switches of git-send-email(1):
git send-email \
--in-reply-to=20200608115714.1139735-1-clg@kaod.org \
--to=clg@kaod.org \
--cc=kvm-ppc@vger.kernel.org \
--cc=kvm@vger.kernel.org \
--cc=linuxppc-dev@lists.ozlabs.org \
--cc=mpe@ellerman.id.au \
--cc=npiggin@gmail.com \
--cc=paulus@samba.org \
/path/to/YOUR_REPLY
https://kernel.org/pub/software/scm/git/docs/git-send-email.html
* If your mail client supports setting the In-Reply-To header
via mailto: links, try the mailto: link
Be sure your reply has a Subject: header at the top and a blank line
before the message body.
This is a public inbox, see mirroring instructions
for how to clone and mirror all data and code used for this inbox