From: Anton Vorontsov <anton.vorontsov@linaro.org>
To: Chanwoo Choi <cw00.choi@samsung.com>
Cc: myungjoo.ham@samsung.com, kyungmin.park@samsung.com,
linux-kernel@vger.kernel.org
Subject: Re: [PATCH v2 2/3] charger-manager: Fix bug when check dropped voltage after fullbatt event
Date: Sun, 16 Dec 2012 22:53:06 -0800 [thread overview]
Message-ID: <20121217064902.GA9027@lizard.gateway.2wire.net> (raw)
In-Reply-To: <1353570831-19439-1-git-send-email-cw00.choi@samsung.com>
On Thu, Nov 22, 2012 at 04:53:51PM +0900, Chanwoo Choi wrote:
> This patch check difference value between current voltage of battery
> and desc->fullbatt_uV whether positve or negative number. If difference
> value is negative number when current voltage of battery is larger than
> desc->fullbatt_uV, charger-manager return immediately because battery
> is fully charged.
>
> Signed-off-by: Chanwoo Choi <cw00.choi@samsung.com>
> Signed-off-by: Myungjoo Ham <myungjoo.ham@samsung.com>
> Signed-off-by: Kyungmin Park <kyungmin.park@samsung.com>
> ---
> drivers/power/charger-manager.c | 9 ++++++---
> 1 files changed, 6 insertions(+), 3 deletions(-)
>
> diff --git a/drivers/power/charger-manager.c b/drivers/power/charger-manager.c
> index ee039b9..17130c7 100644
> --- a/drivers/power/charger-manager.c
> +++ b/drivers/power/charger-manager.c
> @@ -468,7 +468,9 @@ static void fullbatt_vchk(struct work_struct *work)
> struct charger_manager *cm = container_of(dwork,
> struct charger_manager, fullbatt_vchk_work);
> struct charger_desc *desc = cm->desc;
> - int batt_uV, err, diff;
> + int batt_uV;
> + int err;
> + int diff;
I applied the patch, but dropped this part. This is an unrelated style
fix, and, if anything, it desires a separate patch (possibly 'fixing' the
whole file/driver).
Thanks!
> /* remove the appointment for fullbatt_vchk */
> cm->fullbatt_vchk_jiffies_at = 0;
> @@ -482,8 +484,9 @@ static void fullbatt_vchk(struct work_struct *work)
> return;
> }
>
> - diff = desc->fullbatt_uV;
> - diff -= batt_uV;
> + diff = desc->fullbatt_uV - batt_uV;
> + if (diff < 0)
> + return;
>
> dev_info(cm->dev, "VBATT dropped %duV after full-batt.\n", diff);
>
> --
> 1.7.0.4
next prev parent reply other threads:[~2012-12-17 6:56 UTC|newest]
Thread overview: 3+ messages / expand[flat|nested] mbox.gz Atom feed top
2012-11-22 7:53 [PATCH v2 2/3] charger-manager: Fix bug when check dropped voltage after fullbatt event Chanwoo Choi
2012-12-17 6:53 ` Anton Vorontsov [this message]
2012-12-17 7:15 ` Chanwoo Choi
Reply instructions:
You may reply publicly to this message via plain-text email
using any one of the following methods:
* Save the following mbox file, import it into your mail client,
and reply-to-all from there: mbox
Avoid top-posting and favor interleaved quoting:
https://en.wikipedia.org/wiki/Posting_style#Interleaved_style
* Reply using the --to, --cc, and --in-reply-to
switches of git-send-email(1):
git send-email \
--in-reply-to=20121217064902.GA9027@lizard.gateway.2wire.net \
--to=anton.vorontsov@linaro.org \
--cc=cw00.choi@samsung.com \
--cc=kyungmin.park@samsung.com \
--cc=linux-kernel@vger.kernel.org \
--cc=myungjoo.ham@samsung.com \
/path/to/YOUR_REPLY
https://kernel.org/pub/software/scm/git/docs/git-send-email.html
* If your mail client supports setting the In-Reply-To header
via mailto: links, try the mailto: link
Be sure your reply has a Subject: header at the top and a blank line
before the message body.
This is a public inbox, see mirroring instructions
for how to clone and mirror all data and code used for this inbox