From: mark gross <mgross@linux.intel.com>
To: Randy Dunlap <rdunlap@infradead.org>
Cc: mgross@linux.intel.com, markgross@kernel.org, arnd@arndb.de,
bp@suse.de, damien.lemoal@wdc.com, dragan.cvetic@xilinx.com,
gregkh@linuxfoundation.org, corbet@lwn.net,
leonard.crestez@nxp.com, palmerdabbelt@google.com,
paul.walmsley@sifive.com, peng.fan@nxp.com, robh+dt@kernel.org,
shawnguo@kernel.org, linux-kernel@vger.kernel.org
Subject: Re: [PATCH 01/22] Add Vision Processing Unit (VPU) documentation.
Date: Thu, 7 Jan 2021 12:16:14 -0800 [thread overview]
Message-ID: <20210107201614.GA93149@linux.intel.com> (raw)
In-Reply-To: <34734a1c-2cd8-89de-4630-753f49c5fdfa@infradead.org>
On Fri, Dec 18, 2020 at 03:30:18PM -0800, Randy Dunlap wrote:
> Hi--
>
> On 12/1/20 2:34 PM, mgross@linux.intel.com wrote:
> > From: mark gross <mgross@linux.intel.com>
> >
> >
> > Reviewed-by: Mark Gross <mgross@linux.intel.com>
> > Signed-off-by: Mark Gross <mgross@linux.intel.com>
>
> My reading of submitting-patches.rst seems to indicate that
> the Reviewer and Submitter are probably not the same person.
>
> Are you sure that you reviewed it?
>
>
> > ---
> > Documentation/index.rst | 3 +-
> > Documentation/vpu/index.rst | 16 ++
> > Documentation/vpu/vpu-stack-overview.rst | 267 +++++++++++++++++++++++
> > 3 files changed, 285 insertions(+), 1 deletion(-)
> > create mode 100644 Documentation/vpu/index.rst
> > create mode 100644 Documentation/vpu/vpu-stack-overview.rst
> >
> > diff --git a/Documentation/index.rst b/Documentation/index.rst
> > index 57719744774c..0a2cc0204e8f 100644
> > --- a/Documentation/index.rst
> > +++ b/Documentation/index.rst
> > @@ -1,4 +1,4 @@
> > -.. SPDX-License-Identifier: GPL-2.0
> > +.. SPDX-License-Identifier: GPL-2.0-only
>
> That looks both inappropriate for this patch and incorrect AFAICT.
>
> >
> >
> > .. The Linux Kernel documentation master file, created by
> > @@ -137,6 +137,7 @@ needed).
> > misc-devices/index
> > scheduler/index
> > mhi/index
> > + vpu/index
> >
> > Architecture-agnostic documentation
> > -----------------------------------
> > diff --git a/Documentation/vpu/index.rst b/Documentation/vpu/index.rst
> > new file mode 100644
> > index 000000000000..7e290e048910
> > --- /dev/null
> > +++ b/Documentation/vpu/index.rst
> > @@ -0,0 +1,16 @@
> > +.. SPDX-License-Identifier: GPL-2.0-only
>
> license-rules.rst says:
>
> For 'GNU General Public License (GPL) version 2 only' use:
> SPDX-License-Identifier: GPL-2.0
>
> > +
> > +============================================
> > +Vision Processor Unit Documentation
> > +============================================
> > +
> > +This documentation contains information for the Intel VPU stack.
> > +
> > +.. class:: toc-title
> > +
> > + Table of contents
> > +
> > +.. toctree::
> > + :maxdepth: 2
> > +
> > + vpu-stack-overview
> > diff --git a/Documentation/vpu/vpu-stack-overview.rst b/Documentation/vpu/vpu-stack-overview.rst
> > new file mode 100644
> > index 000000000000..53c06a7d9a52
> > --- /dev/null
> > +++ b/Documentation/vpu/vpu-stack-overview.rst
> > @@ -0,0 +1,267 @@
> > +.. SPDX-License-Identifier: GPL-2.0-only
>
> Nope.
>
> > +
> > +======================
> > +Intel VPU architecture
> > +======================
> > +
> > +Overview
> > +========
> > +
> > +The Intel Movidius acquisition has developed a Vision Processing Unit (VPU)
> > +roadmap of products starting with Keem Bay (KMB). The HW configurations the
>
> s/HW/hardware/
>
> > +VPU can support include:
> > +
> > +1. Standalone smart camera that does local CV processing in camera
>
> Tell us what CV is before using it.
>
> > +2. Standalone appliance or SBC device connected to a network and tethered
>
> Tell us what SBC is before using it. (yeah, I know)
>
> > + cameras doing local CV processing
> > +3. Embedded in a USB dongle or M.2 as an CV accelerator.
> > +4. Multiple VPU enabled SOC's on a PCIE card as a CV accelerator in a larger IA
>
> PCIe (?)
>
> > + box or server.
> > +
> > +Keem Bay is the first instance of this family of products. This document
> > +provides an architectural overview of the SW stack supporting the VPU enabled
>
> s/SW/software/
>
> > +products.
> > +
> > +Keem Bay (KMB) is a Computer Vision AI processing SoC based on ARM A53 CPU that
> > +provides Edge neural network acceleration (inference) and includes a Vision
> > +Processing Unit (VPU) hardware. The ARM CPU SubSystem (CPUSS) interfaces
> > +locally to the VPU and enables integration/interfacing with a remote host over
> > +PCIe or USB or Ethernet interfaces. The interface between the CPUSS and the VPU
> > +is implemented with HW FIFOs (Control) and coherent memory mapping (Data) such
> > +that zero copy processing can happen within the VPU.
> > +
> > +The KMB can be used in all 4 of the above classes of designs.
> > +
> > +We refer to the 'local host' as being the ARM part of the SoC, while the
> > +'remote host' as the IA system hosting the KMB device(s). The KMB SoC boots
> > +from an eMMC via uBoot and ARM Linux compatible device tree interface with an
> > +expectation to fully boot within hundreds of milliseconds. There is also
> > +support for downloading the kernel and root file system image from a remote
> > +host.
> > +
> > +The eMMC can be updated with standard mender update process.
>
> Mender
>
> > +See https://github.com/mendersoftware/mender
> > +
> > +The VPU is started and controlled from the A53 local host. Its firmware image
> > +is loaded using the drive FW helper KAPI's.
>
> s/FW/firmware/
>
> > +
> > +The VPU IP FW payload consists of a SPARC ISA RTEMS bootloader and/or
> > +application binary.
> > +
> > +The interface allowing (remote or local) host clients to access VPU IP
>
> ^^drop one space
>
> > +capabilities is realized through an abstracted programming model, which
> > +provides Remote Proxy APIs for a host CPU application to dynamically create and
> > +execute CV and NN workloads on the VPU. All frameworks exposed through
>
> Tell us what NN is.
>
> > +programming model’s APIs are contained in the pre-compiled standard firmware
> > +image.
> > +
> > +There is a significant SW stack built up to support KMB and the use cases. The
> > +rest of this documentation provides an overview of the components of the stack.
> > +
> > +Keem Bay IPC
> > +============
> > +
> > +Directly interfaces with the KMB HW FIFOs to provide zero copy processing from
> > +the VPU. It implements the lowest level protocol for interacting with the VPU.
> > +
> > +The Keem Bay IPC mechanism is based on shared memory and hardware FIFOs,
>
> FIFOs.
>
> > +specifically there are:
>
> Specifically
>
> > +
> > +* Two 128-entry HW FIFOs, one for the CPU and one for the VPU.
> > +* Two shared memory regions, used as memory pool for allocating IPC buffers
>
> end with a period since the previous line did that.
>
> > +
> > +An IPC channel is a software abstraction allowing communication multiplexing,
> > +so that multiple applications / users can concurrently communicated to the VPU.
>
> communicate
>
> > +IPC channels area conceptually similar to socket ports.
> > +
> > +There is a total of 1024 channels, each one identified by a channel ID, ranging
>
> are
>
> > +from 0 to 1023.
> > +
> > +Channels are divided in two categories:
> > +
> > +* High-Speed (HS) channels, having IDs in the 0-9 range.
> > +* General-Purpose (GP) channels, having IDs in the 10-1023 range.
> > +
> > +HS channels have higher priority over GP channels and can be used by
> > +applications requiring higher throughput or lower latency.
> > +
> > +Since all the channels share the same HW resources (i.e., the HW FIFOs and the
> > +IPC memory pools), the Keem Bay IPC driver uses software queues to give a
> > +higher priority to HS channels.
> > +
> > +The driver supports a build-time configurable number of communication channels
> > +defined in a so called Channel Mapping Table.
>
> so-called
>
> > +
> > +An IPC channel is full duplex: a pending operation from a certain channel does
> > +not block other operations on the same channel, regardless of their operation
> > +mode (blocking or non-blocking).
> > +
> > +Operation mode is individually selectable for each channel, per operation
> > +direction (read or write). All operations for that direction comply to
> > +selection.
> > +
> > +
> > +Keem Bay-VPU-IPC
> > +================
> > +
> > +This is the MMIO driver of the VPU IP block inside the SOC. It is a control
> > +driver mapping IPC channel communication to Xlink virtual channels.
> > +
> > +This driver provides the following functionality to other drivers in the
> > +communication stack:
> > +
> > +* VPU IP execution control (firmware load, start, reset)
> > +* VPU IP event notifications (device connected, device disconnected, WDT event)
> > +* VPU IP device status query (OFF, BUSY, READY, ERROR, RECOVERY)
> > +* Communication via the IPC protocol (wrapping the Keem Bay IPC driver and
> > + exposing it to higher level Xlink layer)
> > +
> > +In addition to the above, the driver exposes SoC information (like stepping,
> > +device ID, etc.) to user-space via sysfs.
> > +
> > +This driver depends on the 'Keem Bay IPC' driver, which enables the Keem Bay
> > +IPC communication protocol.
> > +
> > +The driver uses the Firmware API to load the VPU firmware from user-space.
> > +
> > +Xlink-IPC
> > +=========
> > +This component is implementing the IPC specific Xlink protocol. It maps channel
>
> component implements IPC-specific
>
>
> > +IDs to HW FIFO entries, using the Keem Bay VPU IPC driver.
> > +
> > +Some of the main functions this driver provides:
> > +
> > +* establishing a connection with an IPC device
> > +* obtaining a list with the available devices
> > +* obtaining the status for a device
> > +* booting a device
> > +* resetting a device
> > +* opening and closing channels
> > +* issuing read and write operations
> > +
> > +Xlink-core
> > +==========
> > +
> > +This component implements an abstracted set of control and communication APIs
> > +based on channel identification. It is intended to support VPU technology both
> > +at SoC level as well as at IP level, over multiple interfaces.
> > +
> > +It provides symmetrical services, where the producer and the consumer have
> > +the same privileges.
> > +
> > +Xlink driver has the ability to abstract several types of communication
> > +channels underneath, allowing the usage of different interfaces with the same
> > +function calls.
> > +
> > +Xlink services are available to both kernel and user space clients and include:
> > +
> > +* interface abstract control and communication API
> > +* multi device support
> > +* concurrent communication across 4096 communication channels (from 0 to
> > + 0xFFF), with customizable properties
> > +* full duplex channels with multiprocess and multithread support
> > +* channel IDs can be mapped to desired physical interface (PCIE, USB, ETH, IPC)
>
> PCIe
>
> > + via a Channel Mapping Table
> > +* asynchronous fast pass through mode: remote host data packets are directly
>
> passthrough
>
> > + dispatched using interrupt systems running on local host to IPC calls for low
> > + overhead
> > +* channel handshaking mechanism for peer to peer communication, without the
> > + need of static channel preallocation
> > +* channel resource management
> > +* asynchronous data and device notifications to subscribers
> > +
> > +Xlink transports: PCIe, USB, ETH, IPCXLink-PCIe
>
> IPC,
>
> > +
> > +XLink-PCIE
>
> PCIe
>
> > +==========
> > +This is an endpoint driver that is mapping Xlink channel IDs to PCIE channels.
>
> that maps PCIe
>
> > +
> > +This component ensures (remote)host-to-(local)host communication, and VPU IP
> > +communication via an asynchronous pass through mode, where PCIE data loads are
>
> passthrough PCIe
>
>
> > +directly dispatched to Xlink-IPC.
> > +
> > +The component builds and advertises Device IDs that can are used by local host
>
> that are used
>
> > +application in case of multi device scenarios.
> > +
> > +XLink-USB
> > +==========
> > +This is an endpoint driver that is mapping Xlink channel IDs to bidirectional
>
> that maps
>
> > +USB endpoints and supports CDC USB class protocol. More than one Xlink channels
>
> channel
>
> > +can be mapped to a single USB endpoint.
> > +
> > +This component ensures host-to-host communication, and, as well, asynchronous
> > +pass through communication, where USB transfer packets are directly dispatched
>
> passthrough
>
> > +to Xlink-IPC.
> > +
> > +The component builds and advertises Device IDs that can are used by local host
>
> that are used
>
> > +application in case of multi device scenarios.
> > +
> > +XLink-ETH
> > +=========
> > +
> > +This is an endpoint driver that is mapping Xlink channel IDs to Ethernet
>
> that maps
>
> > +sockets.
> > +
> > +This component ensures host-to-host communication, and, as well, asynchronous
> > +pass through communication, where Ethernet data loads are directly dispatched to
>
> passthrough
>
> > +Xlink-IPC.
> > +
> > +The component builds and advertises Device IDs that can are used by local host
>
> that are used
>
> > +application in case of multi device scenarios.
> > +
> > +Assorted drivers that depend on this stack:
> > +
> > +Xlink-SMB
> > +=========
> > +The Intel Edge.AI Computer Vision platforms have to be monitored using platform
> > +devices like sensors, fan controller, IO expander etc. Some of these devices
> > +are memory mapped and some are i2c based. Either of these devices are not
>
> I2C-based. None of these devices is
>
> > +directly accessible to the host.
> > +
> > +The host here refers to the server to which the vision accelerators are
> > +connected over PCIe Interface. The Host needs to do a consolidated action based
> > +on the parameters of platform devices. In general, most of the standard devices
> > +(includes sensors, fan controller, IO expander etc) are I2C/SMBus based and are
>
> SMBus-based
>
> > +used to provide the status of the accelerator. Standard drivers for these
> > +devices are available based on i2c/smbus APIs.
>
> I2C/SMBus
>
> > +
> > +Instead of changing the sensor drivers to adapt to PCIe interface, a generic
> > +i2c adapter "xlink-smbus" which underneath uses xlink as physical medium is
>
> I2C Xlink
>
> > +used. With xlink-smbus, the drivers for the platform devices doesn't need to
>
> don't
>
> > +undergo any interface change.
> > +
> > +TSEN
> > +====
> > +
> > +Thermal sensor driver for exporting thermal events to the local Arm64 host as
> > +well as to the remote X86 host if in the PCIe add in CV accelerator
>
> add-in
>
> > +configuration.
> > +
> > +The driver receiving the junction temperature from different heating points
>
> receives
>
> > +inside the SOC. The driver will receive the temperature on SMBUS connection and
>
> SMBus
>
> > +forward over xlink-smb when in a remote host configuration.
> > +
> > +In Keem Bay, the four thermal junction temperature points are, Media Subsystem
>
> ^no comma
>
> > +(mss), NN subsystem (nce), Compute subsystem (cse) and SOC(Maximum of mss, nce
>
> and SOC (maximum of mss, nce
> > +and cse)
>
> cse).
>
> > +
> > +HDDL
> > +====
> > +
> > +- Exports details of temperature sensor, current sensor and fan controller
> > + present in Intel Edge.AI Computer Vision platforms to IA host.
> > +- Enable Time sync of Intel Edge.AI Computer Vision platform with IA host.
> > +- Handles device connect and disconnect events.
> > +- Receives slave address from the IA host for memory mapped thermal sensors
> > + present in SoC (Documentation/hwmon/intel_tsens_sensors.rst).
> > +- Registers i2c slave device for slaves present in Intel Edge.AI Computer
>
> I2C
>
> > + Vision platform
> > +
> > +
> > +VPUMGR (VPU Manager)
> > +====================
> > +
> > +Bridges firmware on VPU side and applications on CPU user-space, it assists
> > +firmware on VPU side serving multiple user space application processes on CPU
> > +side concurrently while also performing necessary data buffer management on
> > +behalf of VPU IP.
> >
>
>
> --
> ~Randy
Thanks for the great feedback I've just applied it to my tree for the next
posting.
--mark
next prev parent reply other threads:[~2021-01-07 20:18 UTC|newest]
Thread overview: 67+ messages / expand[flat|nested] mbox.gz Atom feed top
2020-12-01 22:34 [PATCH 00/22] Intel Vision Processing Unit base enabling part 1 mgross
2020-12-01 22:34 ` [PATCH 01/22] Add Vision Processing Unit (VPU) documentation mgross
2020-12-18 23:30 ` Randy Dunlap
2021-01-07 20:16 ` mark gross [this message]
2020-12-01 22:34 ` [PATCH 02/22] dt-bindings: Add bindings for Keem Bay IPC driver mgross
2020-12-07 16:01 ` Rob Herring
2020-12-07 18:22 ` mark gross
2020-12-07 18:42 ` Daniele Alessandrelli
2020-12-07 20:31 ` Jassi Brar
2020-12-09 0:12 ` mark gross
2020-12-09 16:49 ` Jassi Brar
2020-12-09 17:33 ` Rob Herring
2020-12-01 22:34 ` [PATCH 03/22] keembay-ipc: Add Keem Bay IPC module mgross
2020-12-02 6:16 ` Greg KH
2020-12-02 17:42 ` mark gross
2020-12-02 19:01 ` Greg KH
2020-12-05 3:35 ` mark gross
2020-12-05 8:40 ` Greg KH
2020-12-05 16:37 ` Gross, Mark
2020-12-07 1:36 ` mark gross
2020-12-02 6:19 ` Greg KH
2020-12-08 18:59 ` Daniele Alessandrelli
2020-12-08 19:48 ` Greg KH
2020-12-10 18:38 ` Daniele Alessandrelli
2020-12-11 8:22 ` Greg KH
2020-12-11 17:26 ` Gross, Mark
2020-12-01 22:34 ` [PATCH 04/22] dt-bindings: Add bindings for Keem Bay VPU IPC driver mgross
2020-12-07 15:57 ` Rob Herring
2020-12-07 21:28 ` mark gross
2020-12-01 22:34 ` [PATCH 05/22] keembay-vpu-ipc: Add Keem Bay VPU IPC module mgross
2020-12-01 22:34 ` [PATCH 06/22] misc: xlink-pcie: Add documentation for XLink PCIe driver mgross
2020-12-18 22:59 ` Randy Dunlap
2020-12-19 0:07 ` mark gross
2020-12-01 22:34 ` [PATCH 07/22] misc: xlink-pcie: lh: Add PCIe EPF driver for Local Host mgross
2020-12-01 22:34 ` [PATCH 08/22] misc: xlink-pcie: lh: Add PCIe EP DMA functionality mgross
2020-12-01 22:34 ` [PATCH 09/22] misc: xlink-pcie: lh: Add core communication logic mgross
2020-12-02 6:18 ` Greg KH
2020-12-02 16:46 ` Thokala, Srikanth
2020-12-01 22:34 ` [PATCH 10/22] misc: xlink-pcie: lh: Prepare changes for adding remote host driver mgross
2020-12-01 22:35 ` [PATCH 11/22] misc: xlink-pcie: rh: Add PCIe EP driver for Remote Host mgross
2020-12-01 22:35 ` [PATCH 12/22] misc: xlink-pcie: rh: Add core communication logic mgross
2020-12-01 22:35 ` [PATCH 13/22] misc: xlink-pcie: Add XLink API interface mgross
2020-12-01 22:35 ` [PATCH 14/22] misc: xlink-pcie: Add asynchronous event notification support for XLink mgross
2020-12-01 22:35 ` [PATCH 15/22] xlink-ipc: Add xlink ipc device tree bindings mgross
2020-12-07 15:58 ` Rob Herring
2020-12-07 21:41 ` mark gross
2020-12-01 22:35 ` [PATCH 16/22] xlink-ipc: Add xlink ipc driver mgross
2020-12-07 2:32 ` Joe Perches
2020-12-11 11:33 ` Kelly, Seamus
2020-12-11 12:14 ` gregkh
2020-12-11 17:12 ` Gross, Mark
2020-12-07 19:53 ` Randy Dunlap
2020-12-01 22:35 ` [PATCH 17/22] xlink-core: Add xlink core device tree bindings mgross
2020-12-07 16:02 ` Rob Herring
2020-12-01 22:35 ` [PATCH 18/22] xlink-core: Add xlink core driver xLink mgross
2020-12-07 21:50 ` Randy Dunlap
2020-12-01 22:35 ` [PATCH 19/22] xlink-core: Enable xlink protocol over pcie mgross
2020-12-01 22:35 ` [PATCH 20/22] xlink-core: Enable VPU IP management and runtime control mgross
2020-12-01 22:35 ` [PATCH 21/22] xlink-core: add async channel and events mgross
2020-12-07 2:55 ` Joe Perches
2020-12-11 11:34 ` Kelly, Seamus
2020-12-01 22:35 ` [PATCH 22/22] xlink-core: factorize xlink_ioctl function by creating sub-functions for each ioctl command mgross
2020-12-07 3:05 ` Joe Perches
2020-12-07 21:59 ` mark gross
2020-12-09 8:30 ` Joe Perches
2020-12-11 11:36 ` Kelly, Seamus
-- strict thread matches above, loose matches on Subject: below --
2020-11-30 23:06 [PATCH 00/22] Intel Vision Processing Unit base enabling part 1 mgross
2020-11-30 23:06 ` [PATCH 01/22] Add Vision Processing Unit (VPU) documentation mgross
Reply instructions:
You may reply publicly to this message via plain-text email
using any one of the following methods:
* Save the following mbox file, import it into your mail client,
and reply-to-all from there: mbox
Avoid top-posting and favor interleaved quoting:
https://en.wikipedia.org/wiki/Posting_style#Interleaved_style
* Reply using the --to, --cc, and --in-reply-to
switches of git-send-email(1):
git send-email \
--in-reply-to=20210107201614.GA93149@linux.intel.com \
--to=mgross@linux.intel.com \
--cc=arnd@arndb.de \
--cc=bp@suse.de \
--cc=corbet@lwn.net \
--cc=damien.lemoal@wdc.com \
--cc=dragan.cvetic@xilinx.com \
--cc=gregkh@linuxfoundation.org \
--cc=leonard.crestez@nxp.com \
--cc=linux-kernel@vger.kernel.org \
--cc=markgross@kernel.org \
--cc=palmerdabbelt@google.com \
--cc=paul.walmsley@sifive.com \
--cc=peng.fan@nxp.com \
--cc=rdunlap@infradead.org \
--cc=robh+dt@kernel.org \
--cc=shawnguo@kernel.org \
/path/to/YOUR_REPLY
https://kernel.org/pub/software/scm/git/docs/git-send-email.html
* If your mail client supports setting the In-Reply-To header
via mailto: links, try the mailto: link
Be sure your reply has a Subject: header at the top and a blank line
before the message body.
This is a public inbox, see mirroring instructions
for how to clone and mirror all data and code used for this inbox;