From: Thomas Richter <tmricht@linux.ibm.com>
To: linux-kernel@vger.kernel.org, linux-perf-users@vger.kernel.org,
	acme@kernel.org, krebbel@linux.ibm.com
Cc: svens@linux.ibm.com, gor@linux.ibm.com, sumanthk@linux.ibm.com,
	hca@linux.ibm.com, Thomas Richter <tmricht@linux.ibm.com>
Subject: [PATCH] perf list: fix short description for some cache events
Date: Wed, 21 Feb 2024 10:19:08 +0100	[thread overview]
Message-ID: <20240221091908.1759083-1-tmricht@linux.ibm.com> (raw)

Correct the short description of the following events:
DCW_REQ, DCW_REQ_CHIP_HIT, DCW_REQ_DRAWER_HIT, DCW_REQ_IV,
DCW_ON_CHIP, DCW_ON_CHIP_IV, DCW_ON_CHIP_CHIP_HIT,
DCW_ON_CHIP_DRAWER_HIT, CW_ON_MODULE, DCW_ON_DRAWER,
DCW_OFF_DRAWER, IDCW_ON_MODULE_IV, IDCW_ON_MODULE_CHIP_HIT,
IDCW_ON_MODULE_DRAWER_HIT, IDCW_ON_DRAWER_IV, IDCW_ON_DRAWER_CHIP_HIT,
IDCW_ON_DRAWER_DRAWER_HIT, IDCW_OFF_DRAWER_IV, IDCW_OFF_DRAWER_CHIP_HIT,
IDCW_OFF_DRAWER_DRAWER_HIT, ICW_REQ, ICW_REQ_IV, CW_REQ_CHIP_HIT,
ICW_REQ_DRAWER_HIT, ICW_ON_CHIP, ICW_ON_CHIP_IV, ICW_ON_CHIP_CHIP_HIT,
ICW_ON_CHIP_DRAWER_HIT, ICW_ON_MODULE and ICW_OFF_DRAWER.

The second Cache should be L2-Cache.

Output before (display diff of the first four events)
  # perf list -d
  DCW_REQ
       [Directory Write Level 1 Data Cache from Cache. Unit: cpum_cf]
  DCW_REQ_CHIP_HIT
       [Directory Write Level 1 Data Cache from Cache with Chip HP \
	       Hit. Unit: cpum_cf]
  DCW_REQ_DRAWER_HIT
       [Directory Write Level 1 Data Cache from Cache with Drawer \
	       HP Hit. Unit: cpum_cf]
  DCW_REQ_IV
       [Directory Write Level 1 Data Cache from Cache with Intervention. \
	       Unit: cpum_cf]

Output after:
  # perf list -d
  DCW_REQ
       [Directory Write Level 1 Data Cache from L2-Cache. Unit: cpum_cf]
  DCW_REQ_CHIP_HIT
       [Directory Write Level 1 Data Cache from L2-Cache with Chip HP \
	       Hit. Unit: cpum_cf]
  DCW_REQ_DRAWER_HIT
       [Directory Write Level 1 Data Cache from L2-Cache with Drawer \
	       HP Hit. Unit: cpum_cf]
  DCW_REQ_IV
       [Directory Write Level 1 Data Cache from L2-Cache with \
	       Intervention. Unit: cpum_cf]

Fixes: 7f76b3113068 ("perf list: Add IBM z16 event description for s390")
Reported-by: Andreas Krebbel <krebbel@linux.ibm.com>
Signed-off-by: Thomas Richter <tmricht@linux.ibm.com>
Acked-by: Andreas Krebbel <krebbel@linux.ibm.com>
---
 .../pmu-events/arch/s390/cf_z16/extended.json | 62 +++++++++----------
 1 file changed, 31 insertions(+), 31 deletions(-)

diff --git a/tools/perf/pmu-events/arch/s390/cf_z16/extended.json b/tools/perf/pmu-events/arch/s390/cf_z16/extended.json
index c2b10ec1c6e0..02cce3a629cb 100644
--- a/tools/perf/pmu-events/arch/s390/cf_z16/extended.json
+++ b/tools/perf/pmu-events/arch/s390/cf_z16/extended.json
@@ -94,77 +94,77 @@
 		"Unit": "CPU-M-CF",
 		"EventCode": "145",
 		"EventName": "DCW_REQ",
-		"BriefDescription": "Directory Write Level 1 Data Cache from Cache",
+		"BriefDescription": "Directory Write Level 1 Data Cache from L2-Cache",
 		"PublicDescription": "A directory write to the Level-1 Data cache directory where the returned cache line was sourced from the requestors Level-2 cache."
 	},
 	{
 		"Unit": "CPU-M-CF",
 		"EventCode": "146",
 		"EventName": "DCW_REQ_IV",
-		"BriefDescription": "Directory Write Level 1 Data Cache from Cache with Intervention",
+		"BriefDescription": "Directory Write Level 1 Data Cache from L2-Cache with Intervention",
 		"PublicDescription": "A directory write to the Level-1 Data cache directory where the returned cache line was sourced from the requestors Level-2 cache with intervention."
 	},
 	{
 		"Unit": "CPU-M-CF",
 		"EventCode": "147",
 		"EventName": "DCW_REQ_CHIP_HIT",
-		"BriefDescription": "Directory Write Level 1 Data Cache from Cache with Chip HP Hit",
+		"BriefDescription": "Directory Write Level 1 Data Cache from L2-Cache with Chip HP Hit",
 		"PublicDescription": "A directory write to the Level-1 Data cache directory where the returned cache line was sourced from the requestors Level-2 cache after using chip level horizontal persistence, Chip-HP hit."
 	},
 	{
 		"Unit": "CPU-M-CF",
 		"EventCode": "148",
 		"EventName": "DCW_REQ_DRAWER_HIT",
-		"BriefDescription": "Directory Write Level 1 Data Cache from Cache with Drawer HP Hit",
+		"BriefDescription": "Directory Write Level 1 Data Cache from L2-Cache with Drawer HP Hit",
 		"PublicDescription": "A directory write to the Level-1 Data cache directory where the returned cache line was sourced from the requestors Level-2 cache after using drawer level horizontal persistence, Drawer-HP hit."
 	},
 	{
 		"Unit": "CPU-M-CF",
 		"EventCode": "149",
 		"EventName": "DCW_ON_CHIP",
-		"BriefDescription": "Directory Write Level 1 Data Cache from On-Chip Cache",
+		"BriefDescription": "Directory Write Level 1 Data Cache from On-Chip L2-Cache",
 		"PublicDescription": "A directory write to the Level-1 Data cache directory where the returned cache line was sourced from an On-Chip Level-2 cache."
 	},
 	{
 		"Unit": "CPU-M-CF",
 		"EventCode": "150",
 		"EventName": "DCW_ON_CHIP_IV",
-		"BriefDescription": "Directory Write Level 1 Data Cache from On-Chip Cache with Intervention",
+		"BriefDescription": "Directory Write Level 1 Data Cache from On-Chip L2-Cache with Intervention",
 		"PublicDescription": "A directory write to the Level-1 Data cache directory where the returned cache line was sourced from an On-Chip Level-2 cache with intervention."
 	},
 	{
 		"Unit": "CPU-M-CF",
 		"EventCode": "151",
 		"EventName": "DCW_ON_CHIP_CHIP_HIT",
-		"BriefDescription": "Directory Write Level 1 Data Cache from On-Chip Cache with Chip HP Hit",
+		"BriefDescription": "Directory Write Level 1 Data Cache from On-Chip L2-Cache with Chip HP Hit",
 		"PublicDescription": "A directory write to the Level-1 Data cache directory where the returned cache line was sourced from an On-Chip Level-2 cache after using chip level horizontal persistence, Chip-HP hit."
 	},
 	{
 		"Unit": "CPU-M-CF",
 		"EventCode": "152",
 		"EventName": "DCW_ON_CHIP_DRAWER_HIT",
-		"BriefDescription": "Directory Write Level 1 Data Cache from On-Chip Cache with Drawer HP Hit",
+		"BriefDescription": "Directory Write Level 1 Data Cache from On-Chip L2-Cache with Drawer HP Hit",
 		"PublicDescription": "A directory write to the Level-1 Data cache directory where the returned cache line was sourced from an On-Chip Level-2 cache using drawer level horizontal persistence, Drawer-HP hit."
 	},
 	{
 		"Unit": "CPU-M-CF",
 		"EventCode": "153",
 		"EventName": "DCW_ON_MODULE",
-		"BriefDescription": "Directory Write Level 1 Data Cache from On-Module Cache",
+		"BriefDescription": "Directory Write Level 1 Data Cache from On-Module L2-Cache",
 		"PublicDescription": "A directory write to the Level-1 Data cache directory where the returned cache line was sourced from an On-Module Level-2 cache."
 	},
 	{
 		"Unit": "CPU-M-CF",
 		"EventCode": "154",
 		"EventName": "DCW_ON_DRAWER",
-		"BriefDescription": "Directory Write Level 1 Data Cache from On-Drawer Cache",
+		"BriefDescription": "Directory Write Level 1 Data Cache from On-Drawer L2-Cache",
 		"PublicDescription": "A directory write to the Level-1 Data cache directory where the returned cache line was sourced from an On-Drawer Level-2 cache."
 	},
 	{
 		"Unit": "CPU-M-CF",
 		"EventCode": "155",
 		"EventName": "DCW_OFF_DRAWER",
-		"BriefDescription": "Directory Write Level 1 Data Cache from Off-Drawer Cache",
+		"BriefDescription": "Directory Write Level 1 Data Cache from Off-Drawer L2-Cache",
 		"PublicDescription": "A directory write to the Level-1 Data cache directory where the returned cache line was sourced from an Off-Drawer Level-2 cache."
 	},
 	{
@@ -199,140 +199,140 @@
 		"Unit": "CPU-M-CF",
 		"EventCode": "160",
 		"EventName": "IDCW_ON_MODULE_IV",
-		"BriefDescription": "Directory Write Level 1 Instruction and Data Cache from On-Module Memory Cache with Intervention",
+		"BriefDescription": "Directory Write Level 1 Instruction and Data Cache from On-Module Memory L2-Cache with Intervention",
 		"PublicDescription": "A directory write to the Level-1 Data or Level-1 Instruction cache directory where the returned cache line was sourced from an On-Module Level-2 cache with intervention."
 	},
 	{
 		"Unit": "CPU-M-CF",
 		"EventCode": "161",
 		"EventName": "IDCW_ON_MODULE_CHIP_HIT",
-		"BriefDescription": "Directory Write Level 1 Instruction and Data Cache from On-Module Memory Cache with Chip Hit",
+		"BriefDescription": "Directory Write Level 1 Instruction and Data Cache from On-Module Memory L2-Cache with Chip Hit",
 		"PublicDescription": "A directory write to the Level-1 Data or Level-1 Instruction cache directory where the returned cache line was sourced from an On-Module Level-2 cache using chip horizontal persistence, Chip-HP hit."
 	},
 	{
 		"Unit": "CPU-M-CF",
 		"EventCode": "162",
 		"EventName": "IDCW_ON_MODULE_DRAWER_HIT",
-		"BriefDescription": "Directory Write Level 1 Instruction and Data Cache from On-Module Memory Cache with Drawer Hit",
+		"BriefDescription": "Directory Write Level 1 Instruction and Data Cache from On-Module Memory L2-Cache with Drawer Hit",
 		"PublicDescription": "A directory write to the Level-1 Data or Level-1 Instruction cache directory where the returned cache line was sourced from an On-Module Level-2 cache using drawer level horizontal persistence, Drawer-HP hit."
 	},
 	{
 		"Unit": "CPU-M-CF",
 		"EventCode": "163",
 		"EventName": "IDCW_ON_DRAWER_IV",
-		"BriefDescription": "Directory Write Level 1 Instruction and Data Cache from On-Drawer Cache with Intervention",
+		"BriefDescription": "Directory Write Level 1 Instruction and Data Cache from On-Drawer L2-Cache with Intervention",
 		"PublicDescription": "A directory write to the Level-1 Data or Level-1 Instruction cache directory where the returned cache line was sourced from an On-Drawer Level-2 cache with intervention."
 	},
 	{
 		"Unit": "CPU-M-CF",
 		"EventCode": "164",
 		"EventName": "IDCW_ON_DRAWER_CHIP_HIT",
-		"BriefDescription": "Directory Write Level 1 Instruction and Data Cache from On-Drawer Cache with Chip Hit",
+		"BriefDescription": "Directory Write Level 1 Instruction and Data Cache from On-Drawer L2-Cache with Chip Hit",
 		"PublicDescription": "A directory write to the Level-1 Data or Level-1 instruction cache directory where the returned cache line was sourced from an On-Drawer Level-2 cache using chip level horizontal persistence, Chip-HP hit."
 	},
 	{
 		"Unit": "CPU-M-CF",
 		"EventCode": "165",
 		"EventName": "IDCW_ON_DRAWER_DRAWER_HIT",
-		"BriefDescription": "Directory Write Level 1 Instruction and Data Cache from On-Drawer Cache with Drawer Hit",
+		"BriefDescription": "Directory Write Level 1 Instruction and Data Cache from On-Drawer L2-Cache with Drawer Hit",
 		"PublicDescription": "A directory write to the Level-1 Data or Level-1 instruction cache directory where the returned cache line was sourced from an On-Drawer Level-2 cache using drawer level horizontal persistence, Drawer-HP hit."
 	},
 	{
 		"Unit": "CPU-M-CF",
 		"EventCode": "166",
 		"EventName": "IDCW_OFF_DRAWER_IV",
-		"BriefDescription": "Directory Write Level 1 Instruction and Data Cache from Off-Drawer Cache with Intervention",
+		"BriefDescription": "Directory Write Level 1 Instruction and Data Cache from Off-Drawer L2-Cache with Intervention",
 		"PublicDescription": "A directory write to the Level-1 Data or Level-1 instruction cache directory where the returned cache line was sourced from an Off-Drawer Level-2 cache with intervention."
 	},
 	{
 		"Unit": "CPU-M-CF",
 		"EventCode": "167",
 		"EventName": "IDCW_OFF_DRAWER_CHIP_HIT",
-		"BriefDescription": "Directory Write Level 1 Instruction and Data Cache from Off-Drawer Cache with Chip Hit",
+		"BriefDescription": "Directory Write Level 1 Instruction and Data Cache from Off-Drawer L2-Cache with Chip Hit",
 		"PublicDescription": "A directory write to the Level-1 Data or Level-1 instruction cache directory where the returned cache line was sourced from an Off-Drawer Level-2 cache using chip level horizontal persistence, Chip-HP hit."
 	},
 	{
 		"Unit": "CPU-M-CF",
 		"EventCode": "168",
 		"EventName": "IDCW_OFF_DRAWER_DRAWER_HIT",
-		"BriefDescription": "Directory Write Level 1 Instruction and Data Cache from Off-Drawer Cache with Drawer Hit",
+		"BriefDescription": "Directory Write Level 1 Instruction and Data Cache from Off-Drawer L2-Cache with Drawer Hit",
 		"PublicDescription": "A directory write to the Level-1 Data or Level-1 Instruction cache directory where the returned cache line was sourced from an Off-Drawer Level-2 cache using drawer level horizontal persistence, Drawer-HP hit."
 	},
 	{
 		"Unit": "CPU-M-CF",
 		"EventCode": "169",
 		"EventName": "ICW_REQ",
-		"BriefDescription": "Directory Write Level 1 Instruction Cache from Cache",
+		"BriefDescription": "Directory Write Level 1 Instruction Cache from L2-Cache",
 		"PublicDescription": "A directory write to the Level-1 Instruction cache directory where the returned cache line was sourced the requestors Level-2 cache."
 	},
 	{
 		"Unit": "CPU-M-CF",
 		"EventCode": "170",
 		"EventName": "ICW_REQ_IV",
-		"BriefDescription": "Directory Write Level 1 Instruction Cache from Cache with Intervention",
+		"BriefDescription": "Directory Write Level 1 Instruction Cache from L2-Cache with Intervention",
 		"PublicDescription": "A directory write to the Level-1 Instruction cache directory where the returned cache line was sourced from the requestors Level-2 cache with intervention."
 	},
 	{
 		"Unit": "CPU-M-CF",
 		"EventCode": "171",
 		"EventName": "ICW_REQ_CHIP_HIT",
-		"BriefDescription": "Directory Write Level 1 Instruction Cache from Cache with Chip HP Hit",
+		"BriefDescription": "Directory Write Level 1 Instruction Cache from L2-Cache with Chip HP Hit",
 		"PublicDescription": "A directory write to the Level-1 Instruction cache directory where the returned cache line was sourced from the requestors Level-2 cache using chip level horizontal persistence, Chip-HP hit."
 	},
 	{
 		"Unit": "CPU-M-CF",
 		"EventCode": "172",
 		"EventName": "ICW_REQ_DRAWER_HIT",
-		"BriefDescription": "Directory Write Level 1 Instruction Cache from Cache with Drawer HP Hit",
+		"BriefDescription": "Directory Write Level 1 Instruction Cache from L2-Cache with Drawer HP Hit",
 		"PublicDescription": "A directory write to the Level-1 Instruction cache directory where the returned cache line was sourced from the requestors Level-2 cache using drawer level horizontal persistence, Drawer-HP hit."
 	},
 	{
 		"Unit": "CPU-M-CF",
 		"EventCode": "173",
 		"EventName": "ICW_ON_CHIP",
-		"BriefDescription": "Directory Write Level 1 Instruction Cache from On-Chip Cache",
+		"BriefDescription": "Directory Write Level 1 Instruction Cache from On-Chip L2-Cache",
 		"PublicDescription": "A directory write to the Level-1 Instruction cache directory where the returned cache line was sourced from an On-Chip Level-2 cache."
 	},
 	{
 		"Unit": "CPU-M-CF",
 		"EventCode": "174",
 		"EventName": "ICW_ON_CHIP_IV",
-		"BriefDescription": "Directory Write Level 1 Instruction Cache from On-Chip Cache with Intervention",
+		"BriefDescription": "Directory Write Level 1 Instruction Cache from On-Chip L2-Cache with Intervention",
 		"PublicDescription": "A directory write to the Level-1 Instruction cache directory where the returned cache line was sourced an On-Chip Level-2 cache with intervention."
 	},
 	{
 		"Unit": "CPU-M-CF",
 		"EventCode": "175",
 		"EventName": "ICW_ON_CHIP_CHIP_HIT",
-		"BriefDescription": "Directory Write Level 1 Instruction Cache from On-Chip Cache with Chip HP Hit",
+		"BriefDescription": "Directory Write Level 1 Instruction Cache from On-Chip L2-Cache with Chip HP Hit",
 		"PublicDescription": "A directory write to the Level-1 Instruction cache directory where the returned cache line was sourced from an On-Chip Level-2 cache using chip level horizontal persistence, Chip-HP hit."
 	},
 	{
 		"Unit": "CPU-M-CF",
 		"EventCode": "176",
 		"EventName": "ICW_ON_CHIP_DRAWER_HIT",
-		"BriefDescription": "Directory Write Level 1 Instruction Cache from On-Chip Cache with Drawer HP Hit",
+		"BriefDescription": "Directory Write Level 1 Instruction Cache from On-Chip L2-Cache with Drawer HP Hit",
 		"PublicDescription": "A directory write to the Level-1 Instruction cache directory where the returned cache line was sourced from an On-Chip level 2 cache using drawer level horizontal persistence, Drawer-HP hit."
 	},
 	{
 		"Unit": "CPU-M-CF",
 		"EventCode": "177",
 		"EventName": "ICW_ON_MODULE",
-		"BriefDescription": "Directory Write Level 1 Instruction Cache from On-Module Cache",
+		"BriefDescription": "Directory Write Level 1 Instruction Cache from On-Module L2-Cache",
 		"PublicDescription": "A directory write to the Level-1 Instruction cache directory where the returned cache line was sourced from an On-Module Level-2 cache."
 	},
 	{
 		"Unit": "CPU-M-CF",
 		"EventCode": "178",
 		"EventName": "ICW_ON_DRAWER",
-		"BriefDescription": "Directory Write Level 1 Instruction Cache from On-Drawer Cache",
+		"BriefDescription": "Directory Write Level 1 Instruction Cache from On-Drawer L2-Cache",
 		"PublicDescription": "A directory write to the Level-1 Instruction cache directory where the returned cache line was sourced an On-Drawer Level-2 cache."
 	},
 	{
 		"Unit": "CPU-M-CF",
 		"EventCode": "179",
 		"EventName": "ICW_OFF_DRAWER",
-		"BriefDescription": "Directory Write Level 1 Instruction Cache from Off-Drawer Cache",
+		"BriefDescription": "Directory Write Level 1 Instruction Cache from Off-Drawer L2-Cache",
 		"PublicDescription": "A directory write to the Level-1 Instruction cache directory where the returned cache line was sourced an Off-Drawer Level-2 cache."
 	},
 	{
-- 
2.43.0


             reply	other threads:[~2024-02-21  9:19 UTC|newest]

Thread overview: 3+ messages / expand[flat|nested]  mbox.gz  Atom feed  top
2024-02-21  9:19 Thomas Richter [this message]
2024-02-21 20:37 ` [PATCH] perf list: fix short description for some cache events Ian Rogers
2024-02-23 21:15 ` Namhyung Kim

Reply instructions:

You may reply publicly to this message via plain-text email
using any one of the following methods:

* Save the following mbox file, import it into your mail client,
  and reply-to-all from there: mbox

  Avoid top-posting and favor interleaved quoting:
  https://en.wikipedia.org/wiki/Posting_style#Interleaved_style

* Reply using the --to, --cc, and --in-reply-to
  switches of git-send-email(1):

  git send-email \
    --in-reply-to=20240221091908.1759083-1-tmricht@linux.ibm.com \
    --to=tmricht@linux.ibm.com \
    --cc=acme@kernel.org \
    --cc=gor@linux.ibm.com \
    --cc=hca@linux.ibm.com \
    --cc=krebbel@linux.ibm.com \
    --cc=linux-kernel@vger.kernel.org \
    --cc=linux-perf-users@vger.kernel.org \
    --cc=sumanthk@linux.ibm.com \
    --cc=svens@linux.ibm.com \
    /path/to/YOUR_REPLY

  https://kernel.org/pub/software/scm/git/docs/git-send-email.html

* If your mail client supports setting the In-Reply-To header
  via mailto: links, try the mailto: link
Be sure your reply has a Subject: header at the top and a blank line before the message body.
This is a public inbox, see mirroring instructions
for how to clone and mirror all data and code used for this inbox