public inbox for linux-kernel@vger.kernel.org
 help / color / mirror / Atom feed
From: Rob Herring <robh@kernel.org>
To: Bjorn Helgaas <helgaas@kernel.org>
Cc: Chen Wang <unicorn_wang@outlook.com>,
	Krzysztof Kozlowski <krzk+dt@kernel.org>,
	Conor Dooley <conor+dt@kernel.org>,
	Chen Wang <unicornxw@gmail.com>,
	kw@linux.com, u.kleine-koenig@baylibre.com,
	aou@eecs.berkeley.edu, arnd@arndb.de, bhelgaas@google.com,
	guoren@kernel.org, inochiama@outlook.com, lee@kernel.org,
	lpieralisi@kernel.org, manivannan.sadhasivam@linaro.org,
	palmer@dabbelt.com, paul.walmsley@sifive.com,
	pbrobinson@gmail.com, devicetree@vger.kernel.org,
	linux-kernel@vger.kernel.org, linux-pci@vger.kernel.org,
	linux-riscv@lists.infradead.org, chao.wei@sophgo.com,
	xiaoguang.xing@sophgo.com, fengchun.li@sophgo.com
Subject: Re: [PATCH v2 1/5] dt-bindings: pci: Add Sophgo SG2042 PCIe host
Date: Tue, 17 Dec 2024 07:10:02 -0600	[thread overview]
Message-ID: <20241217131002.GA1160167-robh@kernel.org> (raw)
In-Reply-To: <20241211192014.GA3302752@bhelgaas>

On Wed, Dec 11, 2024 at 01:20:14PM -0600, Bjorn Helgaas wrote:
> [cc->to: Rob, Krzysztof, Conor because I'm not a DT expert and I'd
> like their thoughts on this idea of describing Root Ports as separate
> children]
> 
> On Wed, Dec 11, 2024 at 05:00:44PM +0800, Chen Wang wrote:
> > On 2024/12/11 1:33, Bjorn Helgaas wrote:
> > > On Mon, Dec 09, 2024 at 03:19:38PM +0800, Chen Wang wrote:
> 
> > > > +      The Cadence IP has two modes of operation, selected by a strap pin.
> > > > +
> > > > +      In the single-link mode, the Cadence PCIe core instance associated
> > > > +      with Link0 is connected to all the lanes and the Cadence PCIe core
> > > > +      instance associated with Link1 is inactive.
> > > > +
> > > > +      In the dual-link mode, the Cadence PCIe core instance associated
> > > > +      with Link0 is connected to the lower half of the lanes and the
> > > > +      Cadence PCIe core instance associated with Link1 is connected to
> > > > +      the upper half of the lanes.
> 
> > > > +      SG2042 contains 2 Cadence IPs and configures the Cores as below:
> > > > +
> > > > +                     +-- Core(Link0) <---> pcie_rc0   +-----------------+
> > > > +                     |                                |                 |
> > > > +      Cadence IP 1 --+                                | cdns_pcie0_ctrl |
> > > > +                     |                                |                 |
> > > > +                     +-- Core(Link1) <---> disabled   +-----------------+
> > > > +
> > > > +                     +-- Core(Link0) <---> pcie_rc1   +-----------------+
> > > > +                     |                                |                 |
> > > > +      Cadence IP 2 --+                                | cdns_pcie1_ctrl |
> > > > +                     |                                |                 |
> > > > +                     +-- Core(Link1) <---> pcie_rc2   +-----------------+
> > > > +
> > > > +      pcie_rcX is pcie node ("sophgo,sg2042-pcie-host") defined in DTS.
> > > > +      cdns_pcie0_ctrl is syscon node ("sophgo,sg2042-pcie-ctrl") defined in DTS
> > > > +
> > > > +      cdns_pcieX_ctrl contains some registers shared by pcie_rcX, even two
> > > > +      RC(Link)s may share different bits of the same register. For example,
> > > > +      cdns_pcie1_ctrl contains registers shared by link0 & link1 for Cadence IP 2.
> 
> > > > +      "sophgo,pcie-port" is defined to flag which core(link) the rc maps to, with
> > > > +      this we can know what registers(bits) we should use.
> 
> > > > +required:
> > > > +  - compatible
> > > > +  - reg
> > > > +  - reg-names
> > > > +  - vendor-id
> > > > +  - device-id
> > > > +  - sophgo,syscon-pcie-ctrl
> > > > +  - sophgo,pcie-port
> > >
> > > It looks like vendor-id and device-id apply to PCI devices, i.e.,
> > > things that will show up in lspci, I assume Root Ports in this case.
> > > Can we make this explicit in the DT, e.g., something like this?
> > > 
> > >    pcie@62000000 {
> > >      compatible = "sophgo,sg2042-pcie-host";
> > >      port0: pci@0,0 {
> > >        vendor-id = <0x1f1c>;
> > >        device-id = <0x2042>;
> > >      };
> > 
> > Sorry, I don't understand your meaning very well.  Referring to the topology
> > diagram I drew above, is it okay to write DTS as follows?
> > 
> > pcie@7060000000 {
> >     compatible = "sophgo,sg2042-pcie-host";
> >     ...... // other properties
> >     pci@0,0 {
> >       vendor-id = <0x1f1c>;
> >       device-id = <0x2042>;
> >     };
> > }
> > 
> > pcie@7062000000 {
> >     compatible = "sophgo,sg2042-pcie-host";
> >     ...... // other properties
> >     pci@0,0 {
> >       vendor-id = <0x1f1c>;
> >       device-id = <0x2042>;
> >     };
> > }
> > 
> > pcie@7062800000 {
> >     compatible = "sophgo,sg2042-pcie-host";
> >     ...... // other properties
> >     pci@1,0 {
> >       vendor-id = <0x1f1c>;
> >       device-id = <0x2042>;
> >     };
> > 
> > }
> 
> Generally makes sense to me.  I'm suggesting that we should start
> describing Root Ports as children of the host bridge node instead of 
> mixing their properties into the host bridge itself.
> 
> Some properties apply to the host bridge, e.g., "bus-range" describes
> the bus number aperture, and "ranges" describes the address
> translation between the upstream CPU address space and the PCI address
> space.
> 
> Others apply specifically to a Root Port, e.g., "num-lanes",
> "max-link-speed", "phys", "vendor-id", "device-id".  I think it will
> help if we can describe these in separate children, especially when
> there are multiple Root Ports.

Agreed.


> Documentation/devicetree/bindings/pci/pci.txt says a Root Port
> should include a reg property that contains the bus/device/function
> number of the RP, e.g.,
> Documentation/devicetree/bindings/pci/nvidia,tegra20-pcie.txt has
> this:
> 
>   pcie-controller@3000 {
>      compatible = "nvidia,tegra30-pcie";
>      pci@1,0 {
>        reg = <0x000800 0 0 0 0>;
>      };
> 
> where the "0x000800 0 0 0 0" means the "pci@1,0" Root Port is at
> 00:01.0 (bus 00, device 01, function 0).  I don't know what the "@1,0"
> part means.
> 
> > And with this change, I can drop the “pcie-port”property and use the port
> > name to figure out the port number, right?
> 
> Seems likely to me.

I don't think device 1 would be the correct address. The RP is almost 
always device 0.

I think instead the 'syscon-pcie-ctrl' should perhaps be modeled as a 
phy with the phy binding. Then the host bridge node can have 1 or 2 phy 
entries depending on if the host uses 1 or 2 links. And the 2nd host 
should have 'status = "disabled";' when it is not used.

Or perhaps just 'num-lanes' would be enough.

Rob


  reply	other threads:[~2024-12-17 13:10 UTC|newest]

Thread overview: 21+ messages / expand[flat|nested]  mbox.gz  Atom feed  top
2024-12-09  7:19 [PATCH v2 0/5] Add PCIe support to Sophgo SG2042 SoC Chen Wang
2024-12-09  7:19 ` [PATCH v2 1/5] dt-bindings: pci: Add Sophgo SG2042 PCIe host Chen Wang
2024-12-10 17:33   ` Bjorn Helgaas
2024-12-11  9:00     ` Chen Wang
2024-12-11 19:20       ` Bjorn Helgaas
2024-12-17 13:10         ` Rob Herring [this message]
2024-12-19  2:34     ` Chen Wang
2024-12-19 12:16       ` Rob Herring
2024-12-20  0:14         ` Chen Wang
2025-01-06 23:55       ` Chen Wang
2025-01-07  0:18       ` Bjorn Helgaas
2025-01-07  0:43         ` Chen Wang
2024-12-09  7:19 ` [PATCH v2 2/5] PCI: sg2042: Add Sophgo SG2042 PCIe driver Chen Wang
2024-12-10 17:31   ` Bjorn Helgaas
2024-12-19  3:23     ` Chen Wang
2024-12-15  9:17   ` kernel test robot
2024-12-15 12:04   ` kernel test robot
2024-12-09  7:20 ` [PATCH v2 3/5] dt-bindings: mfd: syscon: Add sg2042 pcie ctrl compatible Chen Wang
2024-12-10 17:32   ` Bjorn Helgaas
2024-12-09  7:20 ` [PATCH v2 4/5] riscv: sophgo: dts: add pcie controllers for SG2042 Chen Wang
2024-12-09  7:20 ` [PATCH v2 5/5] riscv: sophgo: dts: enable pcie for PioneerBox Chen Wang

Reply instructions:

You may reply publicly to this message via plain-text email
using any one of the following methods:

* Save the following mbox file, import it into your mail client,
  and reply-to-all from there: mbox

  Avoid top-posting and favor interleaved quoting:
  https://en.wikipedia.org/wiki/Posting_style#Interleaved_style

* Reply using the --to, --cc, and --in-reply-to
  switches of git-send-email(1):

  git send-email \
    --in-reply-to=20241217131002.GA1160167-robh@kernel.org \
    --to=robh@kernel.org \
    --cc=aou@eecs.berkeley.edu \
    --cc=arnd@arndb.de \
    --cc=bhelgaas@google.com \
    --cc=chao.wei@sophgo.com \
    --cc=conor+dt@kernel.org \
    --cc=devicetree@vger.kernel.org \
    --cc=fengchun.li@sophgo.com \
    --cc=guoren@kernel.org \
    --cc=helgaas@kernel.org \
    --cc=inochiama@outlook.com \
    --cc=krzk+dt@kernel.org \
    --cc=kw@linux.com \
    --cc=lee@kernel.org \
    --cc=linux-kernel@vger.kernel.org \
    --cc=linux-pci@vger.kernel.org \
    --cc=linux-riscv@lists.infradead.org \
    --cc=lpieralisi@kernel.org \
    --cc=manivannan.sadhasivam@linaro.org \
    --cc=palmer@dabbelt.com \
    --cc=paul.walmsley@sifive.com \
    --cc=pbrobinson@gmail.com \
    --cc=u.kleine-koenig@baylibre.com \
    --cc=unicorn_wang@outlook.com \
    --cc=unicornxw@gmail.com \
    --cc=xiaoguang.xing@sophgo.com \
    /path/to/YOUR_REPLY

  https://kernel.org/pub/software/scm/git/docs/git-send-email.html

* If your mail client supports setting the In-Reply-To header
  via mailto: links, try the mailto: link
Be sure your reply has a Subject: header at the top and a blank line before the message body.
This is a public inbox, see mirroring instructions
for how to clone and mirror all data and code used for this inbox