* [pdx86-platform-drivers-x86:platform-drivers-x86-simatic-ipc 14/14] drivers/platform/x86/siemens/simatic-ipc-batt.c:197:49: warning: use of logical '||' with constant operand
@ 2023-07-31 16:32 kernel test robot
  0 siblings, 0 replies; only message in thread
From: kernel test robot @ 2023-07-31 16:32 UTC (permalink / raw)
  To: xingtong.wu; +Cc: llvm, oe-kbuild-all, Andy Shevchenko, Hans de Goede

tree:   https://git.kernel.org/pub/scm/linux/kernel/git/pdx86/platform-drivers-x86.git platform-drivers-x86-simatic-ipc
head:   c56beff2037549c951042d178de75e535818a98a
commit: c56beff2037549c951042d178de75e535818a98a [14/14] platform/x86/siemens: simatic-ipc-batt: add support for module BX-59A
config: i386-randconfig-i011-20230731 (https://download.01.org/0day-ci/archive/20230801/202308010001.BGYCSQrl-lkp@intel.com/config)
compiler: clang version 16.0.4 (https://github.com/llvm/llvm-project.git ae42196bc493ffe877a7e3dff8be32035dea4d07)
reproduce: (https://download.01.org/0day-ci/archive/20230801/202308010001.BGYCSQrl-lkp@intel.com/reproduce)

If you fix the issue in a separate patch/commit (i.e. not just a new version of
the same patch/commit), kindly add following tags
| Reported-by: kernel test robot <lkp@intel.com>
| Closes: https://lore.kernel.org/oe-kbuild-all/202308010001.BGYCSQrl-lkp@intel.com/

All warnings (new ones prefixed by >>):

>> drivers/platform/x86/siemens/simatic-ipc-batt.c:197:49: warning: use of logical '||' with constant operand [-Wconstant-logical-operand]
                   if (priv.devmode == SIMATIC_IPC_DEVICE_BX_21A || SIMATIC_IPC_DEVICE_BX_59A)
                                                                 ^  ~~~~~~~~~~~~~~~~~~~~~~~~~
   drivers/platform/x86/siemens/simatic-ipc-batt.c:197:49: note: use '|' for a bitwise operation
                   if (priv.devmode == SIMATIC_IPC_DEVICE_BX_21A || SIMATIC_IPC_DEVICE_BX_59A)
                                                                 ^~
                                                                 |
   1 warning generated.


vim +197 drivers/platform/x86/siemens/simatic-ipc-batt.c

   155	
   156	int simatic_ipc_batt_probe(struct platform_device *pdev, struct gpiod_lookup_table *table)
   157	{
   158		struct simatic_ipc_platform *plat;
   159		struct device *dev = &pdev->dev;
   160		struct device *hwmon_dev;
   161		unsigned long flags;
   162		int err;
   163	
   164		plat = pdev->dev.platform_data;
   165		priv.devmode = plat->devmode;
   166	
   167		switch (priv.devmode) {
   168		case SIMATIC_IPC_DEVICE_127E:
   169		case SIMATIC_IPC_DEVICE_227G:
   170		case SIMATIC_IPC_DEVICE_BX_39A:
   171		case SIMATIC_IPC_DEVICE_BX_21A:
   172		case SIMATIC_IPC_DEVICE_BX_59A:
   173			table->dev_id = dev_name(dev);
   174			gpiod_add_lookup_table(table);
   175			break;
   176		case SIMATIC_IPC_DEVICE_227E:
   177			goto nogpio;
   178		default:
   179			return -ENODEV;
   180		}
   181	
   182		priv.gpios[0] = devm_gpiod_get_index(dev, "CMOSBattery empty", 0, GPIOD_IN);
   183		if (IS_ERR(priv.gpios[0])) {
   184			err = PTR_ERR(priv.gpios[0]);
   185			priv.gpios[0] = NULL;
   186			goto out;
   187		}
   188		priv.gpios[1] = devm_gpiod_get_index(dev, "CMOSBattery low", 1, GPIOD_IN);
   189		if (IS_ERR(priv.gpios[1])) {
   190			err = PTR_ERR(priv.gpios[1]);
   191			priv.gpios[1] = NULL;
   192			goto out;
   193		}
   194	
   195		if (table->table[2].key) {
   196			flags = GPIOD_OUT_HIGH;
 > 197			if (priv.devmode == SIMATIC_IPC_DEVICE_BX_21A || SIMATIC_IPC_DEVICE_BX_59A)
   198				flags = GPIOD_OUT_LOW;
   199			priv.gpios[2] = devm_gpiod_get_index(dev, "CMOSBattery meter", 2, flags);
   200			if (IS_ERR(priv.gpios[2])) {
   201				err = PTR_ERR(priv.gpios[1]);
   202				priv.gpios[2] = NULL;
   203				goto out;
   204			}
   205		} else {
   206			priv.gpios[2] = NULL;
   207		}
   208	
   209	nogpio:
   210		hwmon_dev = devm_hwmon_device_register_with_info(dev, KBUILD_MODNAME,
   211								 &priv,
   212								 &simatic_ipc_batt_chip_info,
   213								 NULL);
   214		if (IS_ERR(hwmon_dev)) {
   215			err = PTR_ERR(hwmon_dev);
   216			goto out;
   217		}
   218	
   219		/* warn about aging battery even if userspace never reads hwmon */
   220		simatic_ipc_batt_read_value(dev);
   221	
   222		return 0;
   223	out:
   224		simatic_ipc_batt_remove(pdev, table);
   225	
   226		return err;
   227	}
   228	EXPORT_SYMBOL_GPL(simatic_ipc_batt_probe);
   229	

-- 
0-DAY CI Kernel Test Service
https://github.com/intel/lkp-tests/wiki

^ permalink raw reply	[flat|nested] only message in thread

only message in thread, other threads:[~2023-07-31 16:35 UTC | newest]

Thread overview: (only message) (download: mbox.gz follow: Atom feed
-- links below jump to the message on this page --
2023-07-31 16:32 [pdx86-platform-drivers-x86:platform-drivers-x86-simatic-ipc 14/14] drivers/platform/x86/siemens/simatic-ipc-batt.c:197:49: warning: use of logical '||' with constant operand kernel test robot

This is a public inbox, see mirroring instructions
for how to clone and mirror all data and code used for this inbox