From mboxrd@z Thu Jan 1 00:00:00 1970 From: David Miller Subject: Re: [PATCH] phy: SMSC device Energy Detect power-down mode Date: Fri, 25 Dec 2009 18:38:29 -0800 (PST) Message-ID: <20091225.183829.246551084.davem@davemloft.net> References: <1260948498-28544-1-git-send-email-peppe.cavallaro@st.com> Mime-Version: 1.0 Content-Type: Text/Plain; charset=us-ascii Content-Transfer-Encoding: 7bit Cc: netdev@vger.kernel.org To: peppe.cavallaro@st.com Return-path: Received: from 74-93-104-97-Washington.hfc.comcastbusiness.net ([74.93.104.97]:47195 "EHLO sunset.davemloft.net" rhost-flags-OK-OK-OK-OK) by vger.kernel.org with ESMTP id S1756630AbZLZCi1 (ORCPT ); Fri, 25 Dec 2009 21:38:27 -0500 In-Reply-To: <1260948498-28544-1-git-send-email-peppe.cavallaro@st.com> Sender: netdev-owner@vger.kernel.org List-ID: From: Giuseppe CAVALLARO Date: Wed, 16 Dec 2009 08:28:18 +0100 > SMSC Ethernet Transceivers (LAN88710, LAN8710, LAN8720, LAN8187, > LAN8700, LAN83C185) provide a mechanism to conserve power when > the device is not connected to an active link partner > (Energy Detect Mode). > So this patch enables the Energy Detect power-down mode > for these Transceivers. > > Signed-off-by: Giuseppe Cavallaro Both phy_read() and phy_write() can return errors, you must check for them. The rest of this driver does this properly.