From mboxrd@z Thu Jan 1 00:00:00 1970 From: =?ISO-8859-15?Q?Daniel_Gl=F6ckner?= Subject: PTP_PEROUT_REQUEST and clock stepping Date: Wed, 10 Sep 2014 18:16:37 +0200 Message-ID: <54107965.6040007@emlix.com> Mime-Version: 1.0 Content-Type: text/plain; charset=ISO-8859-15 Content-Transfer-Encoding: QUOTED-PRINTABLE Cc: netdev@vger.kernel.org To: Richard Cochran Return-path: Received: from mx1.emlix.com ([88.198.240.195]:58094 "EHLO mx1.emlix.com" rhost-flags-OK-OK-OK-OK) by vger.kernel.org with ESMTP id S1751341AbaIJQ0r (ORCPT ); Wed, 10 Sep 2014 12:26:47 -0400 Sender: netdev-owner@vger.kernel.org List-ID: Hi, I was wondering how periodic output is supposed to behave if the clock is stepped from a time after ptp_perout_request.start to a time before ptp_perout_request.start. Should the periodic output stop until .start is reached again or should it ignore .start once periodic output has started? Best regards, Daniel --=20 Dipl.-Math. Daniel Gl=F6ckner, emlix GmbH, http://www.emlix.com =46on +49 551 30664-0, Fax +49 551 30664-11, Bertha-von-Suttner-Stra=DFe 9, 37085 G=F6ttingen, Germany Sitz der Gesellschaft: G=F6ttingen, Amtsgericht G=F6ttingen HR B 3160 Gesch=E4ftsf=FChrer: Dr. Uwe Kracke, Ust-IdNr.: DE 205 198 055 emlix - your embedded linux partner