From mboxrd@z Thu Jan 1 00:00:00 1970
From: bugzilla-daemon-CC+yJ3UmIYqDUpFQwHEjaQ@public.gmane.org
Subject: [Bug 80901] [NVCF] PWM fan speed too high
Date: Wed, 09 Jul 2014 16:35:04 +0000
Message-ID:
References:
Mime-Version: 1.0
Content-Type: multipart/mixed; boundary="===============1077725669=="
Return-path:
In-Reply-To:
List-Unsubscribe: ,
List-Archive:
List-Post:
List-Help:
List-Subscribe: ,
Errors-To: nouveau-bounces-PD4FTy7X32lNgt0PjOBp9y5qC8QIuHrW@public.gmane.org
Sender: "Nouveau"
To: nouveau-PD4FTy7X32lNgt0PjOBp9y5qC8QIuHrW@public.gmane.org
List-Id: nouveau.vger.kernel.org
--===============1077725669==
Content-Type: multipart/alternative; boundary="1404923704.1Dd31.11650"; charset="us-ascii"
--1404923704.1Dd31.11650
Date: Wed, 9 Jul 2014 16:35:04 +0000
MIME-Version: 1.0
Content-Type: text/plain; charset="UTF-8"
https://bugs.freedesktop.org/show_bug.cgi?id=80901
--- Comment #15 from Martin Peres ---
(In reply to comment #14)
> The problem I see with trip-points is that those allow to set a fixed PWM
> value when the sensors detect a certain temperature. The nouveau driver
> instead raises the fan speed "continuously" after a certain temperature is
> reached (would we need infinite trip-points for that?).
> Please correct any error in my understanding here :)
>
> Maybe we can use the trip points as a start/end point and then move
> autonomously disregarding the point[0-*]_pwm value?
>
>
> For now, if you agree, I will move the sysfs values as suggested (and change
> the documentation), hopefully before/during next weekend.
> So this bug will still have an almost "clean" patch for anyone (included me)
> who want it.
> Then I will ask around in the lm-sensors mailing list (is it the correct
> one?). Hopefully someone can point me to a better solution.
>
> Thanks for the review! :)
Yes, you understood my review and have a perfect todo list! Good luck with it
:)
--
You are receiving this mail because:
You are the assignee for the bug.
--1404923704.1Dd31.11650
Date: Wed, 9 Jul 2014 16:35:04 +0000
MIME-Version: 1.0
Content-Type: text/html; charset="UTF-8"
Comment # 15
on bug 80901
from Martin Peres
(In reply to comment #14)
> The problem I see with trip-points is that those allow to set a fixed PWM
> value when the sensors detect a certain temperature. The nouveau driver
> instead raises the fan speed "continuously" after a certain temperature is
> reached (would we need infinite trip-points for that?).
> Please correct any error in my understanding here :)
>
> Maybe we can use the trip points as a start/end point and then move
> autonomously disregarding the point[0-*]_pwm value?
>
>
> For now, if you agree, I will move the sysfs values as suggested (and change
> the documentation), hopefully before/during next weekend.
> So this bug will still have an almost "clean" patch for anyone (included me)
> who want it.
> Then I will ask around in the lm-sensors mailing list (is it the correct
> one?). Hopefully someone can point me to a better solution.
>
> Thanks for the review! :)
Yes, you understood my review and have a perfect todo list! Good luck with it
:)
You are receiving this mail because:
- You are the assignee for the bug.
--1404923704.1Dd31.11650--
--===============1077725669==
Content-Type: text/plain; charset="us-ascii"
MIME-Version: 1.0
Content-Transfer-Encoding: 7bit
Content-Disposition: inline
_______________________________________________
Nouveau mailing list
Nouveau-PD4FTy7X32lNgt0PjOBp9y5qC8QIuHrW@public.gmane.org
http://lists.freedesktop.org/mailman/listinfo/nouveau
--===============1077725669==--