From mboxrd@z Thu Jan 1 00:00:00 1970 Content-Type: multipart/mixed; boundary="===============5283339549542545461==" MIME-Version: 1.0 From: Marcel Holtmann Subject: Re: [RFC] plugin/ste: Use D-Bus API from Modem Init Daemon for autoconfig. Date: Wed, 17 Nov 2010 14:00:49 +0100 Message-ID: <1289998849.29148.10.camel@aeonflux> In-Reply-To: List-Id: To: ofono@ofono.org --===============5283339549542545461== Content-Type: text/plain; charset="utf-8" MIME-Version: 1.0 Content-Transfer-Encoding: quoted-printable Hi Sjur, > >> We definitely need a synchronization mechanism between Modem Init Daem= on > >> and the other services, so we decided to use a D-Bus API for the > >> Modem Init Daemon to expose the modem state and an API for initiating > >> power-off, upgrade and reboot. > > > > do you have a link to the D-Bus of this daemon? I would prefer if you > > publish it first or at least the part of it used here. > = > This is an extract of the Modem Init Daemon D-Bus API. > Should I could put this the git for reference e.g. in drivers/stemodem/? > = > Modem Init Deamon > =3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D > = > Service com.stericsson.modeminit > Interface com.stericsson.modeminit.Modem > Object path / so how to you handle the case if you have two or more CAIF based modems in the system? oFono does not impose a limit here. Regards Marcel --===============5283339549542545461==--