On 1/2/23 12:46 PM, Michael S. Tsirkin wrote:
> On Sun, Jan 01, 2023 at 06:52:03PM -0500, Chuck Zmudzinski wrote:
> > Intel specifies that the Intel IGD must occupy slot 2 on the PCI bus,
> > as noted in docs/igd-assign.txt in the Qemu source code.
> >
> > Currently, when the xl toolstack is used to configure a Xen HVM guest with
> > Intel IGD passthrough to the guest with the Qemu upstream device model,
> > a Qemu emulated PCI device will occupy slot 2 and the Intel IGD will occupy
> > a different slot. This problem often prevents the guest from booting.
> >
> > The only available workaround is not good: Configure Xen HVM guests to use
> > the old and no longer maintained Qemu traditional device model available
> > from xenbits.xen.org which does reserve slot 2 for the Intel IGD.
> >
> > To implement this feature in the Qemu upstream device model for Xen HVM
> > guests, introduce the following new functions, types, and macros:
> >
> > * XEN_PT_DEVICE_CLASS declaration, based on the existing TYPE_XEN_PT_DEVICE
> > * XEN_PT_DEVICE_GET_CLASS macro helper function for XEN_PT_DEVICE_CLASS
> > * typedef XenPTQdevRealize function pointer
> > * XEN_PCI_IGD_SLOT_MASK, the value of slot_reserved_mask to reserve slot 2
> > * xen_igd_reserve_slot and xen_igd_clear_slot functions
> >
> > The new xen_igd_reserve_slot function uses the existing slot_reserved_mask
> > member of PCIBus to reserve PCI slot 2 for Xen HVM guests configured using
> > the xl toolstack with the gfx_passthru option enabled, which sets the
> > igd-passthru=on option to Qemu for the Xen HVM machine type.
> >
> > The new xen_igd_reserve_slot function also needs to be implemented in
> > hw/xen/xen_pt_stub.c to prevent FTBFS during the link stage for the case
> > when Qemu is configured with --enable-xen and --disable-xen-pci-passthrough,
> > in which case it does nothing.
> >
> > The new xen_igd_clear_slot function overrides qdev->realize of the parent
> > PCI device class to enable the Intel IGD to occupy slot 2 on the PCI bus
> > since slot 2 was reserved by xen_igd_reserve_slot when the PCI bus was
> > created in hw/i386/pc_piix.c for the case when igd-passthru=on.
> >
> > Move the call to xen_host_pci_device_get, and the associated error
> > handling, from xen_pt_realize to the new xen_igd_clear_slot function to
> > initialize the device class and vendor values which enables the checks for
> > the Intel IGD to succeed. The verification that the host device is an
> > Intel IGD to be passed through is done by checking the domain, bus, slot,
> > and function values as well as by checking that gfx_passthru is enabled,
> > the device class is VGA, and the device vendor in Intel.
> >
> > Signed-off-by: Chuck Zmudzinski <brchuckz@aol.com>
>
> I'm not sure why is the issue xen specific. Can you explain?
> Doesn't it affect kvm too?
Recall from docs/igd-assign.txt that there are two modes for
igd passthrough: legacy and upt, and the igd needs to be
at slot 2 only when using legacy mode which gives one
single guest exclusive access to the Intel igd.
It's only xen specific insofar as xen does not have support
for the upt mode so xen must use legacy mode which
requires the igd to be at slot 2. I am not an expert with
kvm, but if I understand correctly, with kvm one can use
the upt mode with the Intel i915 kvmgt kernel module
and in that case the guest will see a virtual Intel gpu
that can be at any arbitrary slot when using kvmgt, and
also, in that case, more than one guest can access the
igd through the kvmgt kernel module.
Again, I am not an expert and do not have as much
experience with kvm, but if I understand correctly it is
possible to use the legacy mode with kvm and I think you
are correct that if one uses kvm in legacy mode and without
using the Intel i915 kvmgt kernel module, then it would be
necessary to reserve slot 2 for the igd on kvm.
Your question makes me curious, and I have not been able
to determine if anyone has tried igd passthrough using
legacy mode on kvm with recent versions of linux and qemu.
I will try reproducing the problem on kvm in legacy mode with
current versions of linux and qemu and report my findings.
With kvm, there might be enough flexibility to specify the
slot number for every pci device in the guest. Such a
capability is not available using the xenlight toolstack
for managing xen guests, so I have been using this patch
to ensure that the Intel igd is at slot 2 with xen guests
created by the xenlight toolstack.
The patch as is will only fix the problem on xen, so if the
problem exists on kvm also, I agree that the patch should
be modified to also fix it on kvm.
Chuck
next prev parent reply other threads:[~2023-01-02 23:11 UTC|newest]
Thread overview: 20+ messages / expand[flat|nested] mbox.gz Atom feed top
[not found] <830263507e8f1a24a94f81909d5102c4b204e938.1672615492.git.brchuckz.ref@aol.com>
2023-01-01 23:52 ` [PATCH v6] xen/pt: reserve PCI slot 2 for Intel igd-passthru Chuck Zmudzinski
2023-01-02 17:46 ` Michael S. Tsirkin
2023-01-02 23:10 ` Chuck Zmudzinski [this message]
2023-01-03 15:14 ` Alex Williamson
2023-01-03 21:50 ` Chuck Zmudzinski
2023-01-03 22:58 ` Chuck Zmudzinski
2023-01-06 10:52 ` Anthony PERARD via
2023-01-06 14:02 ` Chuck Zmudzinski
2023-01-04 20:47 ` Chuck Zmudzinski
2023-01-05 21:20 ` Chuck Zmudzinski
2023-01-03 18:38 ` Chuck Zmudzinski
2023-01-06 13:00 ` Michael S. Tsirkin
2023-01-06 14:03 ` Anthony PERARD via
2023-01-06 14:10 ` Chuck Zmudzinski
2023-01-06 14:31 ` Chuck Zmudzinski
2023-01-06 15:02 ` Chuck Zmudzinski
2023-01-08 16:01 ` Chuck Zmudzinski
2023-01-06 14:42 ` Anthony PERARD via
2023-01-21 18:06 ` Chuck Zmudzinski
2023-01-22 1:09 ` Chuck Zmudzinski
Reply instructions:
You may reply publicly to this message via plain-text email
using any one of the following methods:
* Save the following mbox file, import it into your mail client,
and reply-to-all from there: mbox
Avoid top-posting and favor interleaved quoting:
https://en.wikipedia.org/wiki/Posting_style#Interleaved_style
* Reply using the --to, --cc, and --in-reply-to
switches of git-send-email(1):
git send-email \
--in-reply-to=c21e933f-0539-9ffb-b2f8-f8e1a279b16f@netscape.net \
--to=brchuckz@netscape.net \
--cc=alex.williamson@redhat.com \
--cc=anthony.perard@citrix.com \
--cc=eduardo@habkost.net \
--cc=marcel.apfelbaum@gmail.com \
--cc=mst@redhat.com \
--cc=paul@xen.org \
--cc=pbonzini@redhat.com \
--cc=qemu-devel@nongnu.org \
--cc=richard.henderson@linaro.org \
--cc=sstabellini@kernel.org \
--cc=xen-devel@lists.xenproject.org \
/path/to/YOUR_REPLY
https://kernel.org/pub/software/scm/git/docs/git-send-email.html
* If your mail client supports setting the In-Reply-To header
via mailto: links, try the mailto: link
Be sure your reply has a Subject: header at the top and a blank line
before the message body.
This is a public inbox, see mirroring instructions
for how to clone and mirror all data and code used for this inbox;
as well as URLs for NNTP newsgroup(s).