* [U-Boot] Error during NAND access
@ 2010-10-19 13:03 alex889
  0 siblings, 0 replies; only message in thread
From: alex889 @ 2010-10-19 13:03 UTC (permalink / raw)
  To: u-boot


Hi,
I have strange phenomena.
I have DM365 baaed board.
In some boards (Not all of them), I get this strange case:
Accessing the NAND (Erase/write), like with saveenv command, followed by
Ethernet access (TFTP/PING) stuck the SW.
Accessing the NAND without prior access to ETHERNET works fine.
I tried to debug this with TI code composer studio.
When accessing the NAND, it seems that the CPUs data bus is hung, and I get
the following message from code composer: 

Warning:

0x40000020/-1032 @ marker 1022
Warning during: Execution, 

The pipeline is stalled owing to 'data bus not ready'
Did you ever encounter such a problem?
Do you know if it is caused by HW problem (Corrupt NAND/DM365), or a fixable
SW bug?

Thanks in advance
Alex

-- 