* [PATCH 0/3] Enable L2 Cache Allocation Technology
@ 2016-08-25  5:21 Yi Sun
  2016-09-17 15:31 ` Meng Xu
  0 siblings, 1 reply; 4+ messages in thread
From: Yi Sun @ 2016-08-25  5:21 UTC (permalink / raw)
  To: xen-devel
  Cc: wei.liu2, he.chen, andrew.cooper3, ian.jackson, yi.y.sun,
	jbeulich, chao.p.peng

Design document is below:
=======================================================================
% Intel L2 Cache Allocation Technology (L2 CAT) Feature
% Revision 1.0

\clearpage

Hi all,

We plan to bring a new PSR (Platform Shared Resource) feature called
Intel L2 Cache Allocation Technology (L2 CAT) to Xen.

This is the initial design of L2 CAT. It might be a little long and
detailed, hope it doesn't matter.

Besides the L2 CAT implementaion, we refactor the psr.c to make it more
flexible to add new features and fulfill the principle, open for extension
but closed for modification. 

Comments and suggestions are welcome :-)

# Basics

---------------- ----------------------------------------------------
         Status: **Tech Preview**

Architecture(s): Intel x86

   Component(s): Hypervisor, toolstack

       Hardware: Atom codename Goldmont and beyond
---------------- ----------------------------------------------------

# Overview

L2 CAT allows an OS or Hypervisor/VMM to control allocation of a
CPU's shared L2 cache based on application priority or Class of Service
(COS). Each CLOS is configured using capacity bitmasks (CBM) which
represent cache capacity and indicate the degree of overlap and
isolation between classes. Once L2 CAT is configured, the processor
allows access to portions of L2 cache according to the established
class of service (COS).

# Technical information

L2 CAT is a member of Intel PSR features and part of CAT, it shares
some base PSR infrastructure in Xen.

## Hardware perspective

L2 CAT defines a new range MSRs to assign different L2 cache access
patterns which are known as CBMs (Capacity BitMask), each CBM is
associated with a COS.

```

                        +----------------------------+----------------+
   IA32_PQR_ASSOC       | MSR (per socket)           |    Address     |
 +----+---+-------+     +----------------------------+----------------+
 |    |COS|       |     | IA32_L2_QOS_MASK_0         |     0xD10      |
 +----+---+-------+     +----------------------------+----------------+
        └-------------> | ...                        |  ...           |
                        +----------------------------+----------------+
                        | IA32_L2_QOS_MASK_n         | 0xD10+n (n<64) |
                        +----------------------------+----------------+
```

When context switch happens, the COS of VCPU is written to per-thread
MSR `IA32_PQR_ASSOC`, and then hardware enforces L2 cache allocation
according to the corresponding CBM.

## The relationship between L2 CAT and L3 CAT/CDP

L2 CAT is independent of L3 CAT/CDP, which means L2 CAT would be enabled
while L3 CAT/CDP is disabled, or L2 CAT and L3 CAT/CDP are all enabled.

L2 CAT uses a new range CBMs from 0xD10 ~ 0xD10+n (n<64), following by
the L3 CAT/CDP CBMs, and supports setting different L2 cache accessing
patterns from L3 cache.

N.B. L2 CAT and L3 CAT/CDP share the same COS field in the same
associate register `IA32_PQR_ASSOC`, which means one COS associate to a
pair of L2 CBM and L3 CBM.
Besides, the max COS of L2 CAT may be different from L3 CAT/CDP (or
other PSR features in future). In some cases, a VM is permitted to have a
COS that is beyond one (or more) of PSR features but within the others. 
For instance, let's assume the max COS of L2 CAT is 8 but the max COS of
L3 CAT is 16, when a VM is assigned 9 as COS, the L3 CBM associated to
COS 9 would be enforced, but for L2 CAT, the behavior is fully open (no
limit) since COS 9 is beyond the max COS (8) of L2 CAT.

## Design Overview

* Core COS/CBM association

  When enforcing L2 CAT, all cores of domains have the same default
  COS (COS0) which associated to the fully open CBM (all ones bitmask)
  to access all L2 cache. The default COS is used only in hypervisor
  and is transparent to tool stack and user.

  System administrator can change PSR allocation policy at runtime by
  tool stack. Since L2 CAT share COS with L3 CAT/CDP, a COS corresponds
  to a 2-tuple, like [L2 CBM, L3 CBM] with only-CAT enabled, when CDP
  is enabled, one COS corresponds to a 3-tuple, like [L2 CBM,
  L3 Code_CBM, L3 Data_CBM]. If neither L3 CAT nor L3 CDP is enabled,
  things would be easier, one COS corresponds to one L2 CBM.

* VCPU schedule

  This part reuses L3 CAT COS infrastructure.

* Multi-sockets

  Different sockets may have different L2 CAT capability (e.g. max COS)
  although it is consistent on the same socket. So the capability of
  per-socket L2 CAT is specified.

## Implementation Description

* Hypervisor interfaces:

  1. Ext: Boot line parameter "psr=cat" now will enable L2 CAT and L3
          CAT if hardware supported.

  2. New: SYSCTL:
          - XEN_SYSCTL_PSR_CAT_get_l2_info: Get L2 CAT information.

  3. New: DOMCTL:
          - XEN_DOMCTL_PSR_CAT_OP_GET_L2_CBM: Get L2 CBM for a domain.
          - XEN_DOMCTL_PSR_CAT_OP_SET_L2_CBM: Set L2 CBM for a domain.

* xl interfaces:

  1. Ext: psr-cat-show -l2 domain-id
          Show L2 cbm for a domain.
          => XEN_SYSCTL_PSR_CAT_get_l2_info /
             XEN_DOMCTL_PSR_CAT_OP_GET_L2_CBM

  2. Ext: psr-mba-set -l2 domain-id cbm
          Set L2 cbm for a domain.
          => XEN_DOMCTL_PSR_CAT_OP_SET_L2_CBM

  3. Ext: psr-hwinfo
          Show PSR HW information, including L2 CAT
          => XEN_SYSCTL_PSR_CAT_get_l2_info

* Key data structure:

   1. Feature list

      ```
      struct feat_list {
          unsigned int feature;
          struct feat_ops ops;
          unsigned int feat_info[MAX_FEAT_INFO_SIZE];
          uint64_t cos_reg_val[MAX_COS_REG_NUM];
          struct feat_list *pNext;
      };
      ```

      When a PSR enforcement feature is enabled, it will be added into a
      feature list. The head of the list is created in psr initialization.
	 
      - Member `feature`

        `feature` is an integer number, to indicate which feature the list member
        corresponds to.

      - Member `ops`

        `ops` maintains a callback function list of the feature. It will be introduced
        in details later.

      - Member `feat_info`

        `feat_info` maintains the feature HW information which can be got through
        psr_hwinfo command.		

      - Member `cos_reg_val`

        `cos_ref_val` is an array to maintain the value set in all COS registers of
        the feature.

   2. Per-socket PSR allocation features information structure

      ```
      struct psr_socket_alloc_info {
          unsigned int features;
          unsigned int nr_feat;
          struct feat_list *pFeat;
          struct psr_ref *cos_ref;
          spinlock_t mask_lock;
      };
      ```

      We collect all PSR allocation features information of a socket in
      this `struct psr_socket_alloc_info`.

      - Member `features`

        `features` is a bitmap, to indicate which feature is enabled on
        current socket. We define `features` bitmap as:

        bit 0~1: L3 CAT status, [01] stands for L3 CAT only and [10]
                 stands for L3 CDP is enalbed.

        bit 2: L2 CAT status.

      - Member `pFeat`

        `pFeat` is the head of the feature list which is enabled on the socket.

      - Member `cos_ref`

        `cos_ref` is an array which maintains the reference of one COS.
        If the COS is used by one domain, the reference will increase one.
        If a domain releases the COS, the reference will decrease one. The
        array is indexed by COS.

   3. Feature operation functions structure

      ```
      struct feat_ops {
          void (*init_feature)(unsigned int eax, unsigned int ebx,
                               unsigned int ecx, unsigned int edx,
                               struct feat_list *pFeat,
                               struct psr_socket_alloc_info *info);
          int (*get_old_set_new)(uint64_t *mask,
                                 struct feat_list *pFeat,
                                 unsigned int old_cos,
                                 enum mask_type type,
                                 uint64_t m);
          int (*compare_mask)(uint64_t *mask, struct feat_list *pFeat,
                              unsigned int cos, bool_t *found);
          unsigned int (*get_cos_max_as_type)(struct feat_list *pFeat,
                                              enum mask_type type);
          unsigned int (*exceed_range)(uint64_t *mask, struct feat_list *pFeat,
                                       unsigned int cos);
          int (*write_msr)(unsigned int cos, uint64_t *mask,
                           struct feat_list *pFeat);
          int (*get_val)(struct feat_list *pFeat, unsigned int cos,
                         enum mask_type type, uint64_t *val);
          int (*get_feat_info)(struct feat_list *pFeat, enum mask_type type,
                               uint32_t *dat0, uint32_t *dat1,
                               uint32_t *dat2);
          unsigned int (*get_max_cos_max)(struct feat_list *pFeat);
      };
      ```

      We abstract above callback functions to encapsulate the feature specific
      behaviors into them. Then, it is easy to add a new feature. We just need:
          1) Implement such ops and callback functions for every feature.
          2) Register the ops into `struct feat_list`.
          3) Add the feature into feature list during CPU initialization.

# User information

* Feature Enabling:

  Add "psr=cat" to boot line parameter to enable all supported level CAT
  features.

* xl interfaces:

  1. `psr-cat-show [OPTIONS] domain-id`:

     Show domain L2 or L3 CAT CBM.
	 
     New option `-l` is added.
     `-l2`: Specify cbm for L2 cache.
     `-l3`: Specify cbm for L3 cache.
	 
     If neither `-l2` nor `-l3` is given, LLC (Last Level Cache) is
     default behavior.
	 
  2. `psr-cat-cbm-set [OPTIONS] domain-id cbm`:

     Set domain L2 or L3 CBM.
	 
     New option `-l` is added.
     `-l2`: Specify cbm for L2 cache.
     `-l3`: Specify cbm for L3 cache.

     If neither `-l2` nor `-l3` is given, LLC (Last Level Cache) is
     default behavior. Since there is no CDP support on L2 cache, so if
     `-l2`, `--code` or `--data` are both given, error message shows.

  3. `psr-hwinfo [OPTIONS]`:

     Show L2 & L3 CAT HW informations on every socket.

# References

[Intel® 64 and IA-32 Architectures Software Developer Manuals](http://www.intel.com/content/www/us/en/processors/architectures-software-developer-manuals.html)

# History

------------------------------------------------------------------------
Date       Revision Version  Notes
---------- -------- -------- -------------------------------------------
2016-08-12 1.0      Xen 4.7  Initial design
---------- -------- -------- -------------------------------------------

Yi Sun (3):
  x86: refactor psr implementation in hypervisor.
  x86: add support for L2 CAT in hypervisor.
  tools & docs: add L2 CAT support in tools and docs.

 docs/man/xl.pod.1.in            |   25 +-
 docs/misc/xl-psr.markdown       |   10 +-
 tools/libxc/include/xenctrl.h   |    7 +-
 tools/libxc/xc_psr.c            |   28 +-
 tools/libxl/libxl.h             |    2 +
 tools/libxl/libxl_psr.c         |   50 +-
 tools/libxl/libxl_types.idl     |    1 +
 tools/libxl/xl_cmdimpl.c        |  191 +++++-
 tools/libxl/xl_cmdtable.c       |    4 +-
 xen/arch/x86/domctl.c           |   49 +-
 xen/arch/x86/psr.c              | 1343 ++++++++++++++++++++++++++++++++-------
 xen/arch/x86/sysctl.c           |   19 +-
 xen/include/asm-x86/msr-index.h |    1 +
 xen/include/asm-x86/psr.h       |   23 +-
 xen/include/public/domctl.h     |    2 +
 xen/include/public/sysctl.h     |    3 +-
 16 files changed, 1433 insertions(+), 325 deletions(-)

-- 
1.9.1


_______________________________________________
Xen-devel mailing list
Xen-devel@lists.xen.org
https://lists.xen.org/xen-devel

^ permalink raw reply	[flat|nested] 4+ messages in thread

* Re: [PATCH 0/3] Enable L2 Cache Allocation Technology
  2016-08-25  5:21 [PATCH 0/3] Enable L2 Cache Allocation Technology Yi Sun
@ 2016-09-17 15:31 ` Meng Xu
  2016-09-18  2:34   ` Yi Sun
  0 siblings, 1 reply; 4+ messages in thread
From: Meng Xu @ 2016-09-17 15:31 UTC (permalink / raw)
  To: Yi Sun
  Cc: Wei Liu, he.chen, Andrew Cooper, Ian Jackson, Jan Beulich,
	Chao Peng, xen-devel@lists.xenproject.org

On Thu, Aug 25, 2016 at 1:21 AM, Yi Sun <yi.y.sun@linux.intel.com> wrote:
>
> Design document is below:
> =======================================================================
> % Intel L2 Cache Allocation Technology (L2 CAT) Feature
> % Revision 1.0
>
> \clearpage
>
> Hi all,
>
> We plan to bring a new PSR (Platform Shared Resource) feature called
> Intel L2 Cache Allocation Technology (L2 CAT) to Xen.
>
> This is the initial design of L2 CAT. It might be a little long and
> detailed, hope it doesn't matter.
>
> Besides the L2 CAT implementaion, we refactor the psr.c to make it more
> flexible to add new features and fulfill the principle, open for extension
> but closed for modification.
>
> Comments and suggestions are welcome :-)


I have some comments/questions. ;-)


>
>
> # Basics
>
> ---------------- ----------------------------------------------------
>          Status: **Tech Preview**
>
> Architecture(s): Intel x86
>
>    Component(s): Hypervisor, toolstack
>
>        Hardware: Atom codename Goldmont and beyond
> ---------------- ----------------------------------------------------
>
> # Overview
>
> L2 CAT allows an OS or Hypervisor/VMM to control allocation of a
> CPU's shared L2 cache based on application priority or Class of Service
> (COS). Each CLOS is configured using capacity bitmasks (CBM) which
> represent cache capacity and indicate the degree of overlap and
> isolation between classes. Once L2 CAT is configured, the processor
> allows access to portions of L2 cache according to the established
> class of service (COS).



The very earlier version of the design at [1] said, "In the initial
implementation, L2 CAT is shown up on Atom codename
Goldmont firstly and there is no platform support both L2 & L3 CAT so far."

I'm wondering if there is any hardware supporting both L2 & L3 CAT now.

[1]http://www.gossamer-threads.com/lists/xen/devel/431142


>
>
> # Technical information
>
> L2 CAT is a member of Intel PSR features and part of CAT, it shares
> some base PSR infrastructure in Xen.
>
> ## Hardware perspective
>
> L2 CAT defines a new range MSRs to assign different L2 cache access
> patterns which are known as CBMs (Capacity BitMask), each CBM is
> associated with a COS.
>
> ```
>
>                         +----------------------------+----------------+
>    IA32_PQR_ASSOC       | MSR (per socket)           |    Address     |
>  +----+---+-------+     +----------------------------+----------------+
>  |    |COS|       |     | IA32_L2_QOS_MASK_0         |     0xD10      |
>  +----+---+-------+     +----------------------------+----------------+
>         └-------------> | ...                        |  ...           |
>                         +----------------------------+----------------+
>                         | IA32_L2_QOS_MASK_n         | 0xD10+n (n<64) |
>                         +----------------------------+----------------+
> ```
>
> When context switch happens, the COS of VCPU is written to per-thread
> MSR `IA32_PQR_ASSOC`, and then hardware enforces L2 cache allocation
> according to the corresponding CBM.
>
> ## The relationship between L2 CAT and L3 CAT/CDP
>
> L2 CAT is independent of L3 CAT/CDP, which means L2 CAT would be enabled
> while L3 CAT/CDP is disabled, or L2 CAT and L3 CAT/CDP are all enabled.

This sentence indicates that both L2 and L3 CAT can be enabled at the same time.
How can I know which CPU supports both L2 and L3 CAT?
Is the support architectural or just on several types of CPUs?
IMHO, it will be good to provide a reference about the type of CPUs
that supports L2 only, and that both L2 and L3.

>
> L2 CAT uses a new range CBMs from 0xD10 ~ 0xD10+n (n<64), following by
> the L3 CAT/CDP CBMs, and supports setting different L2 cache accessing
> patterns from L3 cache.
>
> N.B. L2 CAT and L3 CAT/CDP share the same COS field in the same
> associate register `IA32_PQR_ASSOC`, which means one COS associate to a
> pair of L2 CBM and L3 CBM.
> Besides, the max COS of L2 CAT may be different from L3 CAT/CDP (or
> other PSR features in future). In some cases, a VM is permitted to have a
> COS that is beyond one (or more) of PSR features but within the others.
> For instance, let's assume the max COS of L2 CAT is 8 but the max COS of
> L3 CAT is 16, when a VM is assigned 9 as COS, the L3 CBM associated to
> COS 9 would be enforced, but for L2 CAT, the behavior is fully open (no
> limit) since COS 9 is beyond the max COS (8) of L2 CAT.
>
> ## Design Overview
>
> * Core COS/CBM association
>
>   When enforcing L2 CAT, all cores of domains have the same default
>   COS (COS0) which associated to the fully open CBM (all ones bitmask)
>   to access all L2 cache. The default COS is used only in hypervisor
>   and is transparent to tool stack and user.
>
>   System administrator can change PSR allocation policy at runtime by
>   tool stack. Since L2 CAT share COS with L3 CAT/CDP, a COS corresponds
>   to a 2-tuple, like [L2 CBM, L3 CBM] with only-CAT enabled, when CDP
>   is enabled, one COS corresponds to a 3-tuple, like [L2 CBM,
>   L3 Code_CBM, L3 Data_CBM]. If neither L3 CAT nor L3 CDP is enabled,
>   things would be easier, one COS corresponds to one L2 CBM.


I felt that this paragraph is kind of confusing. Can system admin
configure both L2 and L3 at the same time for a VM?
What does the 2-tuple, like [L2 CBM, L3 CBM], indicates here?

In addition, does the bits in CBM have to be continuous?

> # User information
>
> * Feature Enabling:
>
>   Add "psr=cat" to boot line parameter to enable all supported level CAT
>   features.
>
> * xl interfaces:
>
>   1. `psr-cat-show [OPTIONS] domain-id`:
>
>      Show domain L2 or L3 CAT CBM.
>
>      New option `-l` is added.
>      `-l2`: Specify cbm for L2 cache.
>      `-l3`: Specify cbm for L3 cache.
>
>      If neither `-l2` nor `-l3` is given, LLC (Last Level Cache) is
>      default behavior.

Does it mean the LLC CAT setting will be reset or just kept to the
latest configuration?

>
>   2. `psr-cat-cbm-set [OPTIONS] domain-id cbm`:
>
>      Set domain L2 or L3 CBM.
>
>      New option `-l` is added.
>      `-l2`: Specify cbm for L2 cache.
>      `-l3`: Specify cbm for L3 cache.
>
>      If neither `-l2` nor `-l3` is given, LLC (Last Level Cache) is
>      default behavior. Since there is no CDP support on L2 cache, so if
>      `-l2`, `--code` or `--data` are both given, error message shows.
>
>   3. `psr-hwinfo [OPTIONS]`:
>
>      Show L2 & L3 CAT HW informations on every socket.
>
> # References
>
> [Intel® 64 and IA-32 Architectures Software Developer Manuals](http://www.intel.com/content/www/us/en/processors/architectures-software-developer-manuals.html)

Would you mind provide the chapter for the L2 CAT and the version of
the SDM you are referring?
It makes people's life easier to find the reference. ;-)

>
> # History
>
> ------------------------------------------------------------------------
> Date       Revision Version  Notes
> ---------- -------- -------- -------------------------------------------
> 2016-08-12 1.0      Xen 4.7  Initial design

It seems there is a RFC design in May this year:
http://www.gossamer-threads.com/lists/xen/devel/431142

Shouldn't it be counted?

Thanks,

Meng

-----------
Meng Xu
PhD Student in Computer and Information Science
University of Pennsylvania
http://www.cis.upenn.edu/~mengxu/

_______________________________________________
Xen-devel mailing list
Xen-devel@lists.xen.org
https://lists.xen.org/xen-devel

^ permalink raw reply	[flat|nested] 4+ messages in thread

* Re: [PATCH 0/3] Enable L2 Cache Allocation Technology
  2016-09-17 15:31 ` Meng Xu
@ 2016-09-18  2:34   ` Yi Sun
  2016-09-18 15:26     ` Meng Xu
  0 siblings, 1 reply; 4+ messages in thread
From: Yi Sun @ 2016-09-18  2:34 UTC (permalink / raw)
  To: Meng Xu
  Cc: Wei Liu, he.chen, Andrew Cooper, Ian Jackson, Jan Beulich,
	xen-devel@lists.xenproject.org, Chao Peng

On 16-09-17 11:31:54, Meng Xu wrote:
> On Thu, Aug 25, 2016 at 1:21 AM, Yi Sun <yi.y.sun@linux.intel.com> wrote:
> >
> > Design document is below:
> > =======================================================================
> > % Intel L2 Cache Allocation Technology (L2 CAT) Feature
> > % Revision 1.0
> >
> > \clearpage
> >
> > Hi all,
> >
> > We plan to bring a new PSR (Platform Shared Resource) feature called
> > Intel L2 Cache Allocation Technology (L2 CAT) to Xen.
> >
> > This is the initial design of L2 CAT. It might be a little long and
> > detailed, hope it doesn't matter.
> >
> > Besides the L2 CAT implementaion, we refactor the psr.c to make it more
> > flexible to add new features and fulfill the principle, open for extension
> > but closed for modification.
> >
> > Comments and suggestions are welcome :-)
> 
> 
> I have some comments/questions. ;-)
> 
> 
Thanks for your comments and questions! :)

> >
> >
> > # Basics
> >
> > ---------------- ----------------------------------------------------
> >          Status: **Tech Preview**
> >
> > Architecture(s): Intel x86
> >
> >    Component(s): Hypervisor, toolstack
> >
> >        Hardware: Atom codename Goldmont and beyond
> > ---------------- ----------------------------------------------------
> >
> > # Overview
> >
> > L2 CAT allows an OS or Hypervisor/VMM to control allocation of a
> > CPU's shared L2 cache based on application priority or Class of Service
> > (COS). Each CLOS is configured using capacity bitmasks (CBM) which
> > represent cache capacity and indicate the degree of overlap and
> > isolation between classes. Once L2 CAT is configured, the processor
> > allows access to portions of L2 cache according to the established
> > class of service (COS).
> 
> 
> 
> The very earlier version of the design at [1] said, "In the initial
> implementation, L2 CAT is shown up on Atom codename
> Goldmont firstly and there is no platform support both L2 & L3 CAT so far."
> 
> I'm wondering if there is any hardware supporting both L2 & L3 CAT now.
> 
> [1]http://www.gossamer-threads.com/lists/xen/devel/431142
> 
> 
Per my info, CURRENT HWs does not support both L2 and L3. But from SW view,
we cannot limit this. If both features are enabled in the future HW, SW
should be able to support it.

> >
> >
> > # Technical information
> >
> > L2 CAT is a member of Intel PSR features and part of CAT, it shares
> > some base PSR infrastructure in Xen.
> >
> > ## Hardware perspective
> >
> > L2 CAT defines a new range MSRs to assign different L2 cache access
> > patterns which are known as CBMs (Capacity BitMask), each CBM is
> > associated with a COS.
> >
> > ```
> >
> >                         +----------------------------+----------------+
> >    IA32_PQR_ASSOC       | MSR (per socket)           |    Address     |
> >  +----+---+-------+     +----------------------------+----------------+
> >  |    |COS|       |     | IA32_L2_QOS_MASK_0         |     0xD10      |
> >  +----+---+-------+     +----------------------------+----------------+
> >         └-------------> | ...                        |  ...           |
> >                         +----------------------------+----------------+
> >                         | IA32_L2_QOS_MASK_n         | 0xD10+n (n<64) |
> >                         +----------------------------+----------------+
> > ```
> >
> > When context switch happens, the COS of VCPU is written to per-thread
> > MSR `IA32_PQR_ASSOC`, and then hardware enforces L2 cache allocation
> > according to the corresponding CBM.
> >
> > ## The relationship between L2 CAT and L3 CAT/CDP
> >
> > L2 CAT is independent of L3 CAT/CDP, which means L2 CAT would be enabled
> > while L3 CAT/CDP is disabled, or L2 CAT and L3 CAT/CDP are all enabled.
> 
> This sentence indicates that both L2 and L3 CAT can be enabled at the same time.
> How can I know which CPU supports both L2 and L3 CAT?
> Is the support architectural or just on several types of CPUs?
> IMHO, it will be good to provide a reference about the type of CPUs
> that supports L2 only, and that both L2 and L3.
> 
Like above comment, no HWs support both L2 and L3 SO FAR but we should not
limit this in SW. By CPUID tool or HW spec, you should know which feature
is enabled on CPU.

> >
> > L2 CAT uses a new range CBMs from 0xD10 ~ 0xD10+n (n<64), following by
> > the L3 CAT/CDP CBMs, and supports setting different L2 cache accessing
> > patterns from L3 cache.
> >
> > N.B. L2 CAT and L3 CAT/CDP share the same COS field in the same
> > associate register `IA32_PQR_ASSOC`, which means one COS associate to a
> > pair of L2 CBM and L3 CBM.
> > Besides, the max COS of L2 CAT may be different from L3 CAT/CDP (or
> > other PSR features in future). In some cases, a VM is permitted to have a
> > COS that is beyond one (or more) of PSR features but within the others.
> > For instance, let's assume the max COS of L2 CAT is 8 but the max COS of
> > L3 CAT is 16, when a VM is assigned 9 as COS, the L3 CBM associated to
> > COS 9 would be enforced, but for L2 CAT, the behavior is fully open (no
> > limit) since COS 9 is beyond the max COS (8) of L2 CAT.
> >
> > ## Design Overview
> >
> > * Core COS/CBM association
> >
> >   When enforcing L2 CAT, all cores of domains have the same default
> >   COS (COS0) which associated to the fully open CBM (all ones bitmask)
> >   to access all L2 cache. The default COS is used only in hypervisor
> >   and is transparent to tool stack and user.
> >
> >   System administrator can change PSR allocation policy at runtime by
> >   tool stack. Since L2 CAT share COS with L3 CAT/CDP, a COS corresponds
> >   to a 2-tuple, like [L2 CBM, L3 CBM] with only-CAT enabled, when CDP
> >   is enabled, one COS corresponds to a 3-tuple, like [L2 CBM,
> >   L3 Code_CBM, L3 Data_CBM]. If neither L3 CAT nor L3 CDP is enabled,
> >   things would be easier, one COS corresponds to one L2 CBM.
> 
> 
> I felt that this paragraph is kind of confusing. Can system admin
> configure both L2 and L3 at the same time for a VM?
> What does the 2-tuple, like [L2 CBM, L3 CBM], indicates here?
> 
If HW can support both L2 and L3, admin can configure them one by one from
SW view. To explain 2-tuple and 3-tuple, please refer below figure.

2-tuple:
        -----------------------
        | COS 0 | COS 1 | ... |
        -----------------------
L3 CAT  | 0x7ff | 0x3ff | ... |
        -----------------------
L2 CAT  | 0xff  | 0x3f  | ... |
        -----------------------

3-tuple:
        -----------------------------------------------------
        | COS 0 DATA | COS 0 CODE | COS 1 DATA | COS 1 CODE |
        -----------------------------------------------------
L3 CDP  | 0x7ff      | 0x7ff      | 0x3ff      | 0x3ff      |
        -----------------------------------------------------
        |          COS 0          |         COS 1           |
        -----------------------------------------------------
L2 CAT  |          0xff           |         0x3f            |
        -----------------------------------------------------

There is only one ASSOC MSR register, so a CBM combination(e.g. 3-tuple) will
work When you set COS id(e.g. 1) into ASSOC register. That means below CBM set
works on the CPU.
L3 CDP DATA=0x3ff
L3 CDP CODE=0x3ff
L2 CAT = 0x3f
  
> In addition, does the bits in CBM have to be continuous?
> 
Yes, all CBM bits should be continuous. Thanks for pointing this out!

> > # User information
> >
> > * Feature Enabling:
> >
> >   Add "psr=cat" to boot line parameter to enable all supported level CAT
> >   features.
> >
> > * xl interfaces:
> >
> >   1. `psr-cat-show [OPTIONS] domain-id`:
> >
> >      Show domain L2 or L3 CAT CBM.
> >
> >      New option `-l` is added.
> >      `-l2`: Specify cbm for L2 cache.
> >      `-l3`: Specify cbm for L3 cache.
> >
> >      If neither `-l2` nor `-l3` is given, LLC (Last Level Cache) is
> >      default behavior.
> 
> Does it mean the LLC CAT setting will be reset or just kept to the
> latest configuration?
> 
Here, it means LLC CAT value will be shown.

> >
> >   2. `psr-cat-cbm-set [OPTIONS] domain-id cbm`:
> >
> >      Set domain L2 or L3 CBM.
> >
> >      New option `-l` is added.
> >      `-l2`: Specify cbm for L2 cache.
> >      `-l3`: Specify cbm for L3 cache.
> >
> >      If neither `-l2` nor `-l3` is given, LLC (Last Level Cache) is
> >      default behavior. Since there is no CDP support on L2 cache, so if
> >      `-l2`, `--code` or `--data` are both given, error message shows.
> >
> >   3. `psr-hwinfo [OPTIONS]`:
> >
> >      Show L2 & L3 CAT HW informations on every socket.
> >
> > # References
> >
> > [Intel® 64 and IA-32 Architectures Software Developer Manuals](http://www.intel.com/content/www/us/en/processors/architectures-software-developer-manuals.html)
> 
> Would you mind provide the chapter for the L2 CAT and the version of
> the SDM you are referring?
> It makes people's life easier to find the reference. ;-)
> 
Thank you! I will add it in next version.

You can download the latest version from the link. L2 CAT is vol3, chapter
17.17.

> >
> > # History
> >
> > ------------------------------------------------------------------------
> > Date       Revision Version  Notes
> > ---------- -------- -------- -------------------------------------------
> > 2016-08-12 1.0      Xen 4.7  Initial design
> 
> It seems there is a RFC design in May this year:
> http://www.gossamer-threads.com/lists/xen/devel/431142
> 
> Shouldn't it be counted?
> 
Ok, thanks!

> Thanks,
> 
> Meng
> 
> -----------
> Meng Xu
> PhD Student in Computer and Information Science
> University of Pennsylvania
> http://www.cis.upenn.edu/~mengxu/
> 
> _______________________________________________
> Xen-devel mailing list
> Xen-devel@lists.xen.org
> https://lists.xen.org/xen-devel

_______________________________________________
Xen-devel mailing list
Xen-devel@lists.xen.org
https://lists.xen.org/xen-devel

^ permalink raw reply	[flat|nested] 4+ messages in thread

* Re: [PATCH 0/3] Enable L2 Cache Allocation Technology
  2016-09-18  2:34   ` Yi Sun
@ 2016-09-18 15:26     ` Meng Xu
  0 siblings, 0 replies; 4+ messages in thread
From: Meng Xu @ 2016-09-18 15:26 UTC (permalink / raw)
  To: Yi Sun
  Cc: Wei Liu, he.chen, Andrew Cooper, Ian Jackson, Jan Beulich,
	xen-devel@lists.xenproject.org, Chao Peng

On Sat, Sep 17, 2016 at 10:34 PM, Yi Sun <yi.y.sun@linux.intel.com> wrote:
> On 16-09-17 11:31:54, Meng Xu wrote:
>> On Thu, Aug 25, 2016 at 1:21 AM, Yi Sun <yi.y.sun@linux.intel.com> wrote:
>> >
>> > Design document is below:
>> > =======================================================================
>> > % Intel L2 Cache Allocation Technology (L2 CAT) Feature
>> > % Revision 1.0
>> >
>> > \clearpage
>> >
>> > Hi all,
>> >
>> > We plan to bring a new PSR (Platform Shared Resource) feature called
>> > Intel L2 Cache Allocation Technology (L2 CAT) to Xen.
>> >
>> > This is the initial design of L2 CAT. It might be a little long and
>> > detailed, hope it doesn't matter.
>> >
>> > Besides the L2 CAT implementaion, we refactor the psr.c to make it more
>> > flexible to add new features and fulfill the principle, open for extension
>> > but closed for modification.
>> >
>> > Comments and suggestions are welcome :-)
>>
>>
>> I have some comments/questions. ;-)
>>
>>
> Thanks for your comments and questions! :)
>
>> >
>> >
>> > # Basics
>> >
>> > ---------------- ----------------------------------------------------
>> >          Status: **Tech Preview**
>> >
>> > Architecture(s): Intel x86
>> >
>> >    Component(s): Hypervisor, toolstack
>> >
>> >        Hardware: Atom codename Goldmont and beyond
>> > ---------------- ----------------------------------------------------
>> >
>> > # Overview
>> >
>> > L2 CAT allows an OS or Hypervisor/VMM to control allocation of a
>> > CPU's shared L2 cache based on application priority or Class of Service
>> > (COS). Each CLOS is configured using capacity bitmasks (CBM) which
>> > represent cache capacity and indicate the degree of overlap and
>> > isolation between classes. Once L2 CAT is configured, the processor
>> > allows access to portions of L2 cache according to the established
>> > class of service (COS).
>>
>>
>>
>> The very earlier version of the design at [1] said, "In the initial
>> implementation, L2 CAT is shown up on Atom codename
>> Goldmont firstly and there is no platform support both L2 & L3 CAT so far."
>>
>> I'm wondering if there is any hardware supporting both L2 & L3 CAT now.
>>
>> [1]http://www.gossamer-threads.com/lists/xen/devel/431142
>>
>>
> Per my info, CURRENT HWs does not support both L2 and L3. But from SW view,
> we cannot limit this. If both features are enabled in the future HW, SW
> should be able to support it.

OK. I'm not sure if this is the best way to do it. Since the hw will
be manufactured by Intel, I guess you guys know what the future HW
will be. ;-)

Actually, the Atom processor that support L2 CAT is similar to the
Broadwell processor in the sense that the CAT is only for the
Last-Level Cache.
I'm looking forward to the L2 CAT in the processor that has three
level cache. ;-)

>
>> >
>> >
>> > # Technical information
>> >
>> > L2 CAT is a member of Intel PSR features and part of CAT, it shares
>> > some base PSR infrastructure in Xen.
>> >
>> > ## Hardware perspective
>> >
>> > L2 CAT defines a new range MSRs to assign different L2 cache access
>> > patterns which are known as CBMs (Capacity BitMask), each CBM is
>> > associated with a COS.
>> >
>> > ```
>> >
>> >                         +----------------------------+----------------+
>> >    IA32_PQR_ASSOC       | MSR (per socket)           |    Address     |
>> >  +----+---+-------+     +----------------------------+----------------+
>> >  |    |COS|       |     | IA32_L2_QOS_MASK_0         |     0xD10      |
>> >  +----+---+-------+     +----------------------------+----------------+
>> >         └-------------> | ...                        |  ...           |
>> >                         +----------------------------+----------------+
>> >                         | IA32_L2_QOS_MASK_n         | 0xD10+n (n<64) |
>> >                         +----------------------------+----------------+
>> > ```
>> >
>> > When context switch happens, the COS of VCPU is written to per-thread
>> > MSR `IA32_PQR_ASSOC`, and then hardware enforces L2 cache allocation
>> > according to the corresponding CBM.
>> >
>> > ## The relationship between L2 CAT and L3 CAT/CDP
>> >
>> > L2 CAT is independent of L3 CAT/CDP, which means L2 CAT would be enabled
>> > while L3 CAT/CDP is disabled, or L2 CAT and L3 CAT/CDP are all enabled.
>>
>> This sentence indicates that both L2 and L3 CAT can be enabled at the same time.
>> How can I know which CPU supports both L2 and L3 CAT?
>> Is the support architectural or just on several types of CPUs?
>> IMHO, it will be good to provide a reference about the type of CPUs
>> that supports L2 only, and that both L2 and L3.
>>
> Like above comment, no HWs support both L2 and L3 SO FAR but we should not
> limit this in SW. By CPUID tool or HW spec, you should know which feature
> is enabled on CPU.
>
>> >
>> > L2 CAT uses a new range CBMs from 0xD10 ~ 0xD10+n (n<64), following by
>> > the L3 CAT/CDP CBMs, and supports setting different L2 cache accessing
>> > patterns from L3 cache.
>> >
>> > N.B. L2 CAT and L3 CAT/CDP share the same COS field in the same
>> > associate register `IA32_PQR_ASSOC`, which means one COS associate to a
>> > pair of L2 CBM and L3 CBM.
>> > Besides, the max COS of L2 CAT may be different from L3 CAT/CDP (or
>> > other PSR features in future). In some cases, a VM is permitted to have a
>> > COS that is beyond one (or more) of PSR features but within the others.
>> > For instance, let's assume the max COS of L2 CAT is 8 but the max COS of
>> > L3 CAT is 16, when a VM is assigned 9 as COS, the L3 CBM associated to
>> > COS 9 would be enforced, but for L2 CAT, the behavior is fully open (no
>> > limit) since COS 9 is beyond the max COS (8) of L2 CAT.
>> >
>> > ## Design Overview
>> >
>> > * Core COS/CBM association
>> >
>> >   When enforcing L2 CAT, all cores of domains have the same default
>> >   COS (COS0) which associated to the fully open CBM (all ones bitmask)
>> >   to access all L2 cache. The default COS is used only in hypervisor
>> >   and is transparent to tool stack and user.
>> >
>> >   System administrator can change PSR allocation policy at runtime by
>> >   tool stack. Since L2 CAT share COS with L3 CAT/CDP, a COS corresponds
>> >   to a 2-tuple, like [L2 CBM, L3 CBM] with only-CAT enabled, when CDP
>> >   is enabled, one COS corresponds to a 3-tuple, like [L2 CBM,
>> >   L3 Code_CBM, L3 Data_CBM]. If neither L3 CAT nor L3 CDP is enabled,
>> >   things would be easier, one COS corresponds to one L2 CBM.
>>
>>
>> I felt that this paragraph is kind of confusing. Can system admin
>> configure both L2 and L3 at the same time for a VM?
>> What does the 2-tuple, like [L2 CBM, L3 CBM], indicates here?
>>
> If HW can support both L2 and L3, admin can configure them one by one from
> SW view. To explain 2-tuple and 3-tuple, please refer below figure.
>
> 2-tuple:
>         -----------------------
>         | COS 0 | COS 1 | ... |
>         -----------------------
> L3 CAT  | 0x7ff | 0x3ff | ... |
>         -----------------------
> L2 CAT  | 0xff  | 0x3f  | ... |
>         -----------------------
>
> 3-tuple:
>         -----------------------------------------------------
>         | COS 0 DATA | COS 0 CODE | COS 1 DATA | COS 1 CODE |
>         -----------------------------------------------------
> L3 CDP  | 0x7ff      | 0x7ff      | 0x3ff      | 0x3ff      |
>         -----------------------------------------------------
>         |          COS 0          |         COS 1           |
>         -----------------------------------------------------
> L2 CAT  |          0xff           |         0x3f            |
>         -----------------------------------------------------
>
> There is only one ASSOC MSR register, so a CBM combination(e.g. 3-tuple) will
> work When you set COS id(e.g. 1) into ASSOC register. That means below CBM set
> works on the CPU.
> L3 CDP DATA=0x3ff
> L3 CDP CODE=0x3ff
> L2 CAT = 0x3f

I see. Thank you very much for the explanation!

>
>> In addition, does the bits in CBM have to be continuous?
>>
> Yes, all CBM bits should be continuous. Thanks for pointing this out!

;-)

>
>> > # User information
>> >
>> > * Feature Enabling:
>> >
>> >   Add "psr=cat" to boot line parameter to enable all supported level CAT
>> >   features.
>> >
>> > * xl interfaces:
>> >
>> >   1. `psr-cat-show [OPTIONS] domain-id`:
>> >
>> >      Show domain L2 or L3 CAT CBM.
>> >
>> >      New option `-l` is added.
>> >      `-l2`: Specify cbm for L2 cache.
>> >      `-l3`: Specify cbm for L3 cache.
>> >
>> >      If neither `-l2` nor `-l3` is given, LLC (Last Level Cache) is
>> >      default behavior.
>>
>> Does it mean the LLC CAT setting will be reset or just kept to the
>> latest configuration?
>>
> Here, it means LLC CAT value will be shown.

Then the explanation " If neither `-l2` nor `-l3` is given, LLC (Last
Level Cache) is  default behavior." could change to
"If neither `-l2` nor `-l3` is given, it will output the current LLC
(Last Level Cache) configuration"

Thank you very much!

Meng

-----------
Meng Xu
PhD Student in Computer and Information Science
University of Pennsylvania
http://www.cis.upenn.edu/~mengxu/

_______________________________________________
Xen-devel mailing list
Xen-devel@lists.xen.org
https://lists.xen.org/xen-devel

^ permalink raw reply	[flat|nested] 4+ messages in thread

end of thread, other threads:[~2016-09-18 15:26 UTC | newest]

Thread overview: 4+ messages (download: mbox.gz follow: Atom feed
-- links below jump to the message on this page --
2016-08-25  5:21 [PATCH 0/3] Enable L2 Cache Allocation Technology Yi Sun
2016-09-17 15:31 ` Meng Xu
2016-09-18  2:34   ` Yi Sun
2016-09-18 15:26     ` Meng Xu

This is a public inbox, see mirroring instructions
for how to clone and mirror all data and code used for this inbox;
as well as URLs for NNTP newsgroup(s).