From mboxrd@z Thu Jan 1 00:00:00 1970 From: Simon Martin Subject: Re: [Query] Flow of PCI device dedicated to a domU Date: Tue, 22 Jul 2014 16:56:57 +0100 Message-ID: <1721487090.20140722165657@gmail.com> References: <53C64AF8.90001@citrix.com> <53CE3541.80506@citrix.com> <53CE3DE2.8060908@citrix.com> Mime-Version: 1.0 Content-Type: text/plain; charset="us-ascii" Content-Transfer-Encoding: 7bit Return-path: In-Reply-To: List-Unsubscribe: , List-Post: List-Help: List-Subscribe: , Sender: xen-devel-bounces@lists.xen.org Errors-To: xen-devel-bounces@lists.xen.org To: Stefano Stabellini Cc: Andrew Cooper , Xenbegn developer , ian.campbell@citrix.com, xen-devel@lists.xen.org List-Id: xen-devel@lists.xenproject.org Hello Stefano, > The basic mechanism is that Xen assigns the PCI root complex/host > bridge to Dom0. Dom0 walks the bus and finds out the devices available. > When the user assigns a PCI device to a VM, the toolstack (xl/libxl) > issues hypercalls to remap interrupts and MMIO regions of that device > into the guest VM. I am currently trying writing my own PCI front to access directly a PCI device from my PV guest. If I read this correctly you are saying that the MMIO region is already mapped into my domain by xl? So when I go and read the BAR register from the PCI configuration I can just go and access it directly or do I have to update the VA mapping? -- Best regards, Simon mailto:furryfuttock@gmail.com