* Re: multipath-tools only binding 2 out of 4 paths, bug w/ numerous devices?
[not found] <5B2DB4801E21E64BB49494533CCF208A07330E95@CWYMSX02.Corp.Acxiom.net>
@ 2010-06-18 18:55 ` Christophe Varoqui
[not found] ` <5B2DB4801E21E64BB49494533CCF208A07330EB4@CWYMSX02.Corp.Acxiom.net>
0 siblings, 1 reply; 2+ messages in thread
From: Christophe Varoqui @ 2010-06-18 18:55 UTC (permalink / raw)
To: Costaras Steve - stcost; +Cc: dm-devel
On ven., 2010-06-18 at 13:37 -0500, Costaras Steve - stcost wrote:
> I have a STK Flexline 680 which is presenting 12 2TB LUNS across 4 paths
> (48 devices). They are showing up below correctly as sdb through sdaw.
> They are being encapsulated into dm-0 through dm-11. (dm-12 is a lv).
> As below multipath is working but only using/seeing two of the paths.
> With exception of sdz (FLEX680-000 (3600104f0008baaa17c99eebb00000001)).
> It appears that the 3 & 4 paths that DO NOT show up are with device
> major numbers 66 & 67.
>
> Is this a known bug?
>
Hi,
do you reproduce with upstream multipath-tools ? What distribution and
versions are you using ?
Best regards,
--
Christophe Varoqui <christophe.varoqui@opensvc.com>
OpenSVC
^ permalink raw reply [flat|nested] 2+ messages in thread
end of thread, other threads:[~2010-06-18 20:58 UTC | newest]
Thread overview: 2+ messages (download: mbox.gz follow: Atom feed
-- links below jump to the message on this page --
[not found] <5B2DB4801E21E64BB49494533CCF208A07330E95@CWYMSX02.Corp.Acxiom.net>
2010-06-18 18:55 ` multipath-tools only binding 2 out of 4 paths, bug w/ numerous devices? Christophe Varoqui
[not found] ` <5B2DB4801E21E64BB49494533CCF208A07330EB4@CWYMSX02.Corp.Acxiom.net>
2010-06-18 20:58 ` Christophe Varoqui
This is an external index of several public inboxes,
see mirroring instructions on how to clone and mirror
all data and code used by this external index.