* [PATCH net-next 4/24] bnx2x: put start bd csum in separate function
@ 2011-06-14 11:33 Vlad Zolotarov
0 siblings, 0 replies; only message in thread
From: Vlad Zolotarov @ 2011-06-14 11:33 UTC (permalink / raw)
To: Dave Miller
Cc: netdev@vger.kernel.org, Eilon Greenstein, Dmitry Kravkov,
Yaniv Rosner
From: Dmitry Kravkov <dmitry@broadcom.com>
Signed-off-by: Dmitry Kravkov <dmitry@broadcom.com>
Signed-off-by: Vladislav Zolotarov <vladz@broadcom.com>
Signed-off-by: Eilon Greenstein <eilong@broadcom.com>
---
drivers/net/bnx2x/bnx2x_cmn.c | 34 ++++++++++++++++++++--------------
1 files changed, 20 insertions(+), 14 deletions(-)
diff --git a/drivers/net/bnx2x/bnx2x_cmn.c b/drivers/net/bnx2x/bnx2x_cmn.c
index 3742514..d8e6571 100644
--- a/drivers/net/bnx2x/bnx2x_cmn.c
+++ b/drivers/net/bnx2x/bnx2x_cmn.c
@@ -2134,6 +2134,24 @@ static inline u8 bnx2x_set_pbd_csum_e2(struct bnx2x *bp, struct sk_buff *skb,
sizeof(struct udphdr) - skb->data;
}
+static inline void bnx2x_set_sbd_csum(struct bnx2x *bp, struct sk_buff *skb,
+ struct eth_tx_start_bd *tx_start_bd, u32 xmit_type)
+{
+
+ tx_start_bd->bd_flags.as_bitfield |= ETH_TX_BD_FLAGS_L4_CSUM;
+
+ if (xmit_type & XMIT_CSUM_V4)
+ tx_start_bd->bd_flags.as_bitfield |=
+ ETH_TX_BD_FLAGS_IP_CSUM;
+ else
+ tx_start_bd->bd_flags.as_bitfield |=
+ ETH_TX_BD_FLAGS_IPV6;
+
+ if (!(xmit_type & XMIT_CSUM_TCP))
+ tx_start_bd->bd_flags.as_bitfield |= ETH_TX_BD_FLAGS_IS_UDP;
+
+}
+
/**
* bnx2x_set_pbd_csum - update PBD with checksum and return header length
*
@@ -2305,20 +2323,8 @@ netdev_tx_t bnx2x_start_xmit(struct sk_buff *skb, struct net_device *dev)
/* turn on parsing and get a BD */
bd_prod = TX_BD(NEXT_TX_IDX(bd_prod));
- if (xmit_type & XMIT_CSUM) {
- tx_start_bd->bd_flags.as_bitfield |= ETH_TX_BD_FLAGS_L4_CSUM;
-
- if (xmit_type & XMIT_CSUM_V4)
- tx_start_bd->bd_flags.as_bitfield |=
- ETH_TX_BD_FLAGS_IP_CSUM;
- else
- tx_start_bd->bd_flags.as_bitfield |=
- ETH_TX_BD_FLAGS_IPV6;
-
- if (!(xmit_type & XMIT_CSUM_TCP))
- tx_start_bd->bd_flags.as_bitfield |=
- ETH_TX_BD_FLAGS_IS_UDP;
- }
+ if (xmit_type & XMIT_CSUM)
+ bnx2x_set_sbd_csum(bp, skb, tx_start_bd, xmit_type);
if (CHIP_IS_E2(bp)) {
pbd_e2 = &fp->tx_desc_ring[bd_prod].parse_bd_e2;
--
1.7.2.2
^ permalink raw reply related [flat|nested] only message in thread
only message in thread, other threads:[~2011-06-14 11:33 UTC | newest]
Thread overview: (only message) (download: mbox.gz follow: Atom feed
-- links below jump to the message on this page --
2011-06-14 11:33 [PATCH net-next 4/24] bnx2x: put start bd csum in separate function Vlad Zolotarov
This is an external index of several public inboxes,
see mirroring instructions on how to clone and mirror
all data and code used by this external index.