Hello Amit,

On Thu, May 08, 2014 at 08:07:58PM +0530, Amit Daniel Kachhap wrote:
> This patch adds suuport to get P state ceil/floor level for nearest frequency.
> This will be used for consolidating ACPI cpufreq cooling via the generic cpu
> cooling framework.
> 
> Signed-off-by: Amit Daniel Kachhap <amit.daniel@samsung.com>
> ---
>  drivers/thermal/cpu_cooling.c                   |   42 +++++++++++++++++------
>  drivers/thermal/samsung/exynos_thermal_common.c |    3 +-
>  include/linux/cpu_cooling.h                     |   23 ++++++++++++-
>  3 files changed, 55 insertions(+), 13 deletions(-)
> 
> diff --git a/drivers/thermal/cpu_cooling.c b/drivers/thermal/cpu_cooling.c
> index e2aeb36..6f5430e 100644
> --- a/drivers/thermal/cpu_cooling.c
> +++ b/drivers/thermal/cpu_cooling.c
> @@ -120,12 +120,7 @@ static int is_cpufreq_valid(int cpu)
>  	return !cpufreq_get_policy(&policy, cpu);
>  }
>  
> -enum cpufreq_cooling_property {
> -	GET_LEVEL,
> -	GET_FREQ,
> -	GET_MAXL,
> -};
> -
> +#define GET_FREQ (GET_MAXL + 1)

What happens if we add another level manipulating after GET_MAXL? say,
GET_MINL?

>  /**
>   * get_property - fetch a property of interest for a give cpu.
>   * @cpu: cpu for which the property is required
> @@ -207,15 +202,37 @@ static int get_property(unsigned int cpu, unsigned long input,
>  		/* now we have a valid frequency entry */
>  		freq = table[i].frequency;
>  
> -		if (property == GET_LEVEL && (unsigned int)input == freq) {
> +		if (property == GET_LEVEL_EXACT &&
> +					(unsigned int)input == freq) {
>  			/* get level by frequency */
>  			*output = descend ? j : (max_level - j);
>  			return 0;
> -		}
> -		if (property == GET_FREQ && level == j) {
> +		} else if (property == GET_FREQ && level == j) {
>  			/* get frequency by level */
>  			*output = freq;
>  			return 0;
> +		} else if (property == GET_LEVEL_FLOOR) {
> +			/* get minimum possible level by frequency */
> +			if (descend && freq <= input) {
> +				*output = j;
> +				return 0;
> +			} else if (!descend) {
> +				if (freq <= input)
> +					*output = (max_level - j);
> +				else
> +					return 0;
> +			}
> +		} else if (property == GET_LEVEL_CEIL) {
> +			/* get maximum possible level by frequency */
> +			if (!descend && freq >= input) {
> +				*output = (max_level - j);
> +				return 0;
> +			} else if (descend) {
> +				if (freq >= input)
> +					*output = j;
> +				else
> +					return 0;
> +			}
>  		}
>  		j++;
>  	}
> @@ -227,6 +244,8 @@ static int get_property(unsigned int cpu, unsigned long input,
>   * cpufreq_cooling_get_level - for a give cpu, return the cooling level.
>   * @cpu: cpu for which the level is required
>   * @freq: the frequency of interest
> + * @property: can be GET_LEVEL_CEIL, GET_LEVEL_FLOOR, GET_LEVEL_EXACT or
> + * GET_MAXL
>   *
>   * This function will match the cooling level corresponding to the
>   * requested @freq and return it.
> @@ -234,11 +253,12 @@ static int get_property(unsigned int cpu, unsigned long input,
>   * Return: The matched cooling level on success or THERMAL_CSTATE_INVALID
>   * otherwise.
>   */
> -unsigned long cpufreq_cooling_get_level(unsigned int cpu, unsigned int freq)
> +unsigned long cpufreq_cooling_get_level(unsigned int cpu, unsigned int freq,
> +			enum cpufreq_cooling_property property)
>  {
>  	unsigned int val;
>  
> -	if (get_property(cpu, (unsigned long)freq, &val, GET_LEVEL))
> +	if (get_property(cpu, (unsigned long)freq, &val, property))
>  		return THERMAL_CSTATE_INVALID;
>  
>  	return (unsigned long)val;
> diff --git a/drivers/thermal/samsung/exynos_thermal_common.c b/drivers/thermal/samsung/exynos_thermal_common.c
> index a7306fa..aa4696b 100644
> --- a/drivers/thermal/samsung/exynos_thermal_common.c
> +++ b/drivers/thermal/samsung/exynos_thermal_common.c
> @@ -156,7 +156,8 @@ static int exynos_bind(struct thermal_zone_device *thermal,
>  	/* Bind the thermal zone to the cpufreq cooling device */
>  	for (i = 0; i < tab_size; i++) {
>  		clip_data = (struct freq_clip_table *)&(tab_ptr[i]);
> -		level = cpufreq_cooling_get_level(0, clip_data->freq_clip_max);
> +		level = cpufreq_cooling_get_level(0, clip_data->freq_clip_max,
> +						GET_LEVEL_EXACT);
>  		if (level == THERMAL_CSTATE_INVALID)
>  			return 0;
>  		switch (GET_ZONE(i)) {
> diff --git a/include/linux/cpu_cooling.h b/include/linux/cpu_cooling.h
> index f786935..f4d2b0e 100644
> --- a/include/linux/cpu_cooling.h
> +++ b/include/linux/cpu_cooling.h
> @@ -44,6 +44,13 @@ struct cpufreq_cooling_status {
>  	void *devdata;
>  };
>  
> +enum cpufreq_cooling_property {
> +	GET_LEVEL_CEIL,
> +	GET_LEVEL_FLOOR,
> +	GET_LEVEL_EXACT,
> +	GET_MAXL,
> +};

Please document this enum.

> +
>  #ifdef CONFIG_CPU_THERMAL
>  /**
>   * cpufreq_cooling_register - function to create cpufreq cooling device.
> @@ -77,7 +84,21 @@ of_cpufreq_cooling_register(struct device_node *np,
>   */
>  void cpufreq_cooling_unregister(struct thermal_cooling_device *cdev);
>  
> -unsigned long cpufreq_cooling_get_level(unsigned int cpu, unsigned int freq);
> +/**
> + * cpufreq_cooling_get_level - for a give cpu, return the cooling level.
> + * @cpu: cpu for which the level is required
> + * @freq: the frequency of interest
> + * @property: can be GET_LEVEL_CEIL, GET_LEVEL_FLOOR, GET_LEVEL_EXACT or
> + * GET_MAXL
> + *
> + * This function will match the cooling level corresponding to the
> + * requested @freq and return it.
> + *
> + * Return: The matched cooling level on success or THERMAL_CSTATE_INVALID
> + * otherwise.
> + */
> +unsigned long cpufreq_cooling_get_level(unsigned int cpu, unsigned int freq,
> +					enum cpufreq_cooling_property);
>  
>  /**
>   * cpufreq_cooling_register_notifier - register a driver with cpufreq cooling.
> -- 
> 1.7.1
> 
> --
> To unsubscribe from this list: send the line "unsubscribe linux-kernel" in
> the body of a message to majordomo@vger.kernel.org
> More majordomo info at  http://vger.kernel.org/majordomo-info.html
> Please read the FAQ at  http://www.tux.org/lkml/

WARNING: multiple messages have this Message-ID (diff)
From: edubezval@gmail.com (Eduardo Valentin)
To: linux-arm-kernel@lists.infradead.org
Subject: [RFC PATCH 3/5] thermal: cpu_cooling: Add support to find nearby frequency levels.
Date: Thu, 15 May 2014 14:52:54 -0400	[thread overview]
Message-ID: <20140515185254.GC3138@developer> (raw)
In-Reply-To: <1399559880-20562-4-git-send-email-amit.daniel@samsung.com>

Hello Amit,

On Thu, May 08, 2014 at 08:07:58PM +0530, Amit Daniel Kachhap wrote:
> This patch adds suuport to get P state ceil/floor level for nearest frequency.
> This will be used for consolidating ACPI cpufreq cooling via the generic cpu
> cooling framework.
> 
> Signed-off-by: Amit Daniel Kachhap <amit.daniel@samsung.com>
> ---
>  drivers/thermal/cpu_cooling.c                   |   42 +++++++++++++++++------
>  drivers/thermal/samsung/exynos_thermal_common.c |    3 +-
>  include/linux/cpu_cooling.h                     |   23 ++++++++++++-
>  3 files changed, 55 insertions(+), 13 deletions(-)
> 
> diff --git a/drivers/thermal/cpu_cooling.c b/drivers/thermal/cpu_cooling.c
> index e2aeb36..6f5430e 100644
> --- a/drivers/thermal/cpu_cooling.c
> +++ b/drivers/thermal/cpu_cooling.c
> @@ -120,12 +120,7 @@ static int is_cpufreq_valid(int cpu)
>  	return !cpufreq_get_policy(&policy, cpu);
>  }
>  
> -enum cpufreq_cooling_property {
> -	GET_LEVEL,
> -	GET_FREQ,
> -	GET_MAXL,
> -};
> -
> +#define GET_FREQ (GET_MAXL + 1)

What happens if we add another level manipulating after GET_MAXL? say,
GET_MINL?

>  /**
>   * get_property - fetch a property of interest for a give cpu.
>   * @cpu: cpu for which the property is required
> @@ -207,15 +202,37 @@ static int get_property(unsigned int cpu, unsigned long input,
>  		/* now we have a valid frequency entry */
>  		freq = table[i].frequency;
>  
> -		if (property == GET_LEVEL && (unsigned int)input == freq) {
> +		if (property == GET_LEVEL_EXACT &&
> +					(unsigned int)input == freq) {
>  			/* get level by frequency */
>  			*output = descend ? j : (max_level - j);
>  			return 0;
> -		}
> -		if (property == GET_FREQ && level == j) {
> +		} else if (property == GET_FREQ && level == j) {
>  			/* get frequency by level */
>  			*output = freq;
>  			return 0;
> +		} else if (property == GET_LEVEL_FLOOR) {
> +			/* get minimum possible level by frequency */
> +			if (descend && freq <= input) {
> +				*output = j;
> +				return 0;
> +			} else if (!descend) {
> +				if (freq <= input)
> +					*output = (max_level - j);
> +				else
> +					return 0;
> +			}
> +		} else if (property == GET_LEVEL_CEIL) {
> +			/* get maximum possible level by frequency */
> +			if (!descend && freq >= input) {
> +				*output = (max_level - j);
> +				return 0;
> +			} else if (descend) {
> +				if (freq >= input)
> +					*output = j;
> +				else
> +					return 0;
> +			}
>  		}
>  		j++;
>  	}
> @@ -227,6 +244,8 @@ static int get_property(unsigned int cpu, unsigned long input,
>   * cpufreq_cooling_get_level - for a give cpu, return the cooling level.
>   * @cpu: cpu for which the level is required
>   * @freq: the frequency of interest
> + * @property: can be GET_LEVEL_CEIL, GET_LEVEL_FLOOR, GET_LEVEL_EXACT or
> + * GET_MAXL
>   *
>   * This function will match the cooling level corresponding to the
>   * requested @freq and return it.
> @@ -234,11 +253,12 @@ static int get_property(unsigned int cpu, unsigned long input,
>   * Return: The matched cooling level on success or THERMAL_CSTATE_INVALID
>   * otherwise.
>   */
> -unsigned long cpufreq_cooling_get_level(unsigned int cpu, unsigned int freq)
> +unsigned long cpufreq_cooling_get_level(unsigned int cpu, unsigned int freq,
> +			enum cpufreq_cooling_property property)
>  {
>  	unsigned int val;
>  
> -	if (get_property(cpu, (unsigned long)freq, &val, GET_LEVEL))
> +	if (get_property(cpu, (unsigned long)freq, &val, property))
>  		return THERMAL_CSTATE_INVALID;
>  
>  	return (unsigned long)val;
> diff --git a/drivers/thermal/samsung/exynos_thermal_common.c b/drivers/thermal/samsung/exynos_thermal_common.c
> index a7306fa..aa4696b 100644
> --- a/drivers/thermal/samsung/exynos_thermal_common.c
> +++ b/drivers/thermal/samsung/exynos_thermal_common.c
> @@ -156,7 +156,8 @@ static int exynos_bind(struct thermal_zone_device *thermal,
>  	/* Bind the thermal zone to the cpufreq cooling device */
>  	for (i = 0; i < tab_size; i++) {
>  		clip_data = (struct freq_clip_table *)&(tab_ptr[i]);
> -		level = cpufreq_cooling_get_level(0, clip_data->freq_clip_max);
> +		level = cpufreq_cooling_get_level(0, clip_data->freq_clip_max,
> +						GET_LEVEL_EXACT);
>  		if (level == THERMAL_CSTATE_INVALID)
>  			return 0;
>  		switch (GET_ZONE(i)) {
> diff --git a/include/linux/cpu_cooling.h b/include/linux/cpu_cooling.h
> index f786935..f4d2b0e 100644
> --- a/include/linux/cpu_cooling.h
> +++ b/include/linux/cpu_cooling.h
> @@ -44,6 +44,13 @@ struct cpufreq_cooling_status {
>  	void *devdata;
>  };
>  
> +enum cpufreq_cooling_property {
> +	GET_LEVEL_CEIL,
> +	GET_LEVEL_FLOOR,
> +	GET_LEVEL_EXACT,
> +	GET_MAXL,
> +};

Please document this enum.

> +
>  #ifdef CONFIG_CPU_THERMAL
>  /**
>   * cpufreq_cooling_register - function to create cpufreq cooling device.
> @@ -77,7 +84,21 @@ of_cpufreq_cooling_register(struct device_node *np,
>   */
>  void cpufreq_cooling_unregister(struct thermal_cooling_device *cdev);
>  
> -unsigned long cpufreq_cooling_get_level(unsigned int cpu, unsigned int freq);
> +/**
> + * cpufreq_cooling_get_level - for a give cpu, return the cooling level.
> + * @cpu: cpu for which the level is required
> + * @freq: the frequency of interest
> + * @property: can be GET_LEVEL_CEIL, GET_LEVEL_FLOOR, GET_LEVEL_EXACT or
> + * GET_MAXL
> + *
> + * This function will match the cooling level corresponding to the
> + * requested @freq and return it.
> + *
> + * Return: The matched cooling level on success or THERMAL_CSTATE_INVALID
> + * otherwise.
> + */
> +unsigned long cpufreq_cooling_get_level(unsigned int cpu, unsigned int freq,
> +					enum cpufreq_cooling_property);
>  
>  /**
>   * cpufreq_cooling_register_notifier - register a driver with cpufreq cooling.
> -- 
> 1.7.1
> 
> --
> To unsubscribe from this list: send the line "unsubscribe linux-kernel" in
> the body of a message to majordomo at vger.kernel.org
> More majordomo info at  http://vger.kernel.org/majordomo-info.html
> Please read the FAQ at  http://www.tux.org/lkml/

  reply	other threads:[~2014-05-15 18:47 UTC|newest]

Thread overview: 40+ messages / expand[flat|nested]  mbox.gz  Atom feed  top
2014-05-08 14:37 [RFC PATCH 0/5] ACPI: thermal: Migrate cpufreq cooling to generic cpu_cooling layer Amit Daniel Kachhap
2014-05-08 14:37 ` Amit Daniel Kachhap
2014-05-08 14:37 ` [RFC PATCH 1/5] thermal: cpu_cooling: Support passing driver private data Amit Daniel Kachhap
2014-05-08 14:37   ` Amit Daniel Kachhap
2014-05-15 18:33   ` Eduardo Valentin
2014-05-15 18:33     ` Eduardo Valentin
2014-05-16 22:31     ` Rafael J. Wysocki
2014-05-16 22:31       ` Rafael J. Wysocki
2014-05-19  8:56       ` amit daniel kachhap
2014-05-19  8:56         ` amit daniel kachhap
2014-05-19  8:55     ` [linux-pm] " amit daniel kachhap
2014-05-19  8:55       ` amit daniel kachhap
2014-05-08 14:37 ` [RFC PATCH 2/5] thermal: cpu_cooling: Add notifications support for the clients Amit Daniel Kachhap
2014-05-08 14:37   ` Amit Daniel Kachhap
2014-05-15 18:45   ` Eduardo Valentin
2014-05-15 18:45     ` Eduardo Valentin
2014-05-19  8:59     ` [linux-pm] " amit daniel kachhap
2014-05-19  8:59       ` amit daniel kachhap
2014-05-16 17:32   ` Javi Merino
2014-05-16 17:32     ` Javi Merino
2014-05-19  9:01     ` amit daniel kachhap
2014-05-19  9:01       ` amit daniel kachhap
2014-05-08 14:37 ` [RFC PATCH 3/5] thermal: cpu_cooling: Add support to find nearby frequency levels Amit Daniel Kachhap
2014-05-08 14:37   ` Amit Daniel Kachhap
2014-05-15 18:52   ` Eduardo Valentin [this message]
2014-05-15 18:52     ` Eduardo Valentin
2014-05-19  9:20     ` [linux-pm] " amit daniel kachhap
2014-05-19  9:20       ` amit daniel kachhap
2014-05-08 14:37 ` [RFC PATCH 4/5] thermal: cpu_cooling: Release the upper cooling limit checks Amit Daniel Kachhap
2014-05-08 14:37   ` Amit Daniel Kachhap
2014-05-15 18:58   ` Eduardo Valentin
2014-05-15 18:58     ` Eduardo Valentin
2014-05-19  9:15     ` [linux-pm] " amit daniel kachhap
2014-05-19  9:15       ` amit daniel kachhap
2014-05-08 14:38 ` [RFC PATCH 5/5] ACPI: thermal: processor: Use the generic cpufreq infrastructure Amit Daniel Kachhap
2014-05-08 14:38   ` Amit Daniel Kachhap
2014-05-15 19:06   ` Eduardo Valentin
2014-05-15 19:06     ` Eduardo Valentin
2014-05-19  9:09     ` [linux-pm] " amit daniel kachhap
2014-05-19  9:09       ` amit daniel kachhap

Reply instructions:

You may reply publicly to this message via plain-text email
using any one of the following methods:

* Save the following mbox file, import it into your mail client,
  and reply-to-all from there: mbox

  Avoid top-posting and favor interleaved quoting:
  https://en.wikipedia.org/wiki/Posting_style#Interleaved_style

* Reply using the --to, --cc, and --in-reply-to
  switches of git-send-email(1):

  git send-email \
    --in-reply-to=20140515185254.GC3138@developer \
    --to=edubezval@gmail.com \
    --cc=amit.daniel@samsung.com \
    --cc=eduardo.valentin@ti.com \
    --cc=lenb@kernel.org \
    --cc=linux-acpi@vger.kernel.org \
    --cc=linux-arm-kernel@lists.infradead.org \
    --cc=linux-kernel@vger.kernel.org \
    --cc=linux-pm@lists.linux-foundation.org \
    --cc=rjw@rjwysocki.net \
    --cc=rui.zhang@intel.com \
    /path/to/YOUR_REPLY

  https://kernel.org/pub/software/scm/git/docs/git-send-email.html

* If your mail client supports setting the In-Reply-To header
  via mailto: links, try the mailto: link
Be sure your reply has a Subject: header at the top and a blank line before the message body.
This is an external index of several public inboxes,
see mirroring instructions on how to clone and mirror
all data and code used by this external index.