From: Sudeep Holla <sudeep.holla@arm.com>
To: Viresh Kumar <viresh.kumar@linaro.org>
Cc: Dietmar Eggemann <dietmar.eggemann@arm.com>,
"Rafael J . Wysocki" <rjw@rjwysocki.net>,
Liviu Dudau <liviu.dudau@arm.com>,
Sudeep Holla <sudeep.holla@arm.com>,
Lorenzo Pieralisi <lorenzo.pieralisi@arm.com>,
Morten Rasmussen <morten.rasmussen@arm.com>,
Lukasz Luba <lukasz.luba@arm.com>,
linux-pm@vger.kernel.org, linux-arm-kernel@lists.infradead.org,
linux-kernel@vger.kernel.org
Subject: Re: [PATCH] cpufreq: vexpress-spc: Fix wrong alternation of policy->related_cpus during CPU hp
Date: Wed, 27 Nov 2019 13:32:01 +0000 [thread overview]
Message-ID: <20191127133200.GE29301@bogus> (raw)
In-Reply-To: <20191127121402.vd3tul4gmqm6qtyb@vireshk-i7>
On Wed, Nov 27, 2019 at 05:44:02PM +0530, Viresh Kumar wrote:
> On 27-11-19, 12:08, Sudeep Holla wrote:
> > On Wed, Nov 27, 2019 at 12:48:01PM +0100, Dietmar Eggemann wrote:
> > > Since commit ca74b316df96 ("arm: Use common cpu_topology structure and
> > > functions.") the core cpumask has to be modified during cpu hotplug
> > > operations.
> > >
> > > ("arm: Fix topology setup in case of CPU hotplug for CONFIG_SCHED_MC")
> > > [1] fixed that but revealed another issue on TC2, i.e in its cpufreq
> > > driver.
> > >
> > > During CPU hp stress operations on multiple CPUs, policy->related_cpus
> > > can be altered. This is wrong since this cpumask should contain the
> > > online and offline CPUs.
> > >
> > > The WARN_ON(!cpumask_test_cpu(cpu, policy->related_cpus)) in
> > > cpufreq_online() triggers in this case.
> > >
> > > The core cpumask can't be used to set the policy->cpus in
> > > ve_spc_cpufreq_init() anymore in case it is called via
> > > cpuhp_cpufreq_online()->cpufreq_online()->cpufreq_driver->init().
> > >
> > > An empty online() callback can be used to avoid that the init()
> > > driver function is called during CPU hotplug in so that
> > > policy->related_cpus will not be changed.
> > >
> >
> > Unlike DT based drivers, it not easy to get the fixed cpumask unless we
> > add some mechanism to extract it based on clks/OPP added. I prefer
> > this simple solution instead.
>
> I will call this a work-around for the problem and not really the
> solution, though I won't necessarily oppose it. There are cases which
> will break even with this solution.
>
I agree and that's the reason I spoke out my thought aloud here :)
> - Boot board with cpufreq driver as module.
> - Offline all CPUs except CPU0.
> - insert cpufreq driver.
> - online all CPUs.
>
Indeed, not just boot anytime since it's a module :)
> Now there is no guarantee that the last online will get the mask
> properly, if I have understood the problem well :)
>
Yes
> But yeah, who does this kind of messy work anyway :)
>
I won't bet on that ;)
> FWIW, we need a proper way (may be from architecture code) to find
> list of all CPUs that share clock line.
>
Yes but there's no architectural way. I need to revise and see tc2_pm.c
to check if we can do any magic there.
--
Regards,
Sudeep
WARNING: multiple messages have this Message-ID (diff)
From: Sudeep Holla <sudeep.holla@arm.com>
To: Viresh Kumar <viresh.kumar@linaro.org>
Cc: Lorenzo Pieralisi <lorenzo.pieralisi@arm.com>,
linux-pm@vger.kernel.org,
"Rafael J . Wysocki" <rjw@rjwysocki.net>,
Liviu Dudau <liviu.dudau@arm.com>,
linux-kernel@vger.kernel.org,
Dietmar Eggemann <dietmar.eggemann@arm.com>,
linux-arm-kernel@lists.infradead.org,
Sudeep Holla <sudeep.holla@arm.com>,
Morten Rasmussen <morten.rasmussen@arm.com>,
Lukasz Luba <lukasz.luba@arm.com>
Subject: Re: [PATCH] cpufreq: vexpress-spc: Fix wrong alternation of policy->related_cpus during CPU hp
Date: Wed, 27 Nov 2019 13:32:01 +0000 [thread overview]
Message-ID: <20191127133200.GE29301@bogus> (raw)
In-Reply-To: <20191127121402.vd3tul4gmqm6qtyb@vireshk-i7>
On Wed, Nov 27, 2019 at 05:44:02PM +0530, Viresh Kumar wrote:
> On 27-11-19, 12:08, Sudeep Holla wrote:
> > On Wed, Nov 27, 2019 at 12:48:01PM +0100, Dietmar Eggemann wrote:
> > > Since commit ca74b316df96 ("arm: Use common cpu_topology structure and
> > > functions.") the core cpumask has to be modified during cpu hotplug
> > > operations.
> > >
> > > ("arm: Fix topology setup in case of CPU hotplug for CONFIG_SCHED_MC")
> > > [1] fixed that but revealed another issue on TC2, i.e in its cpufreq
> > > driver.
> > >
> > > During CPU hp stress operations on multiple CPUs, policy->related_cpus
> > > can be altered. This is wrong since this cpumask should contain the
> > > online and offline CPUs.
> > >
> > > The WARN_ON(!cpumask_test_cpu(cpu, policy->related_cpus)) in
> > > cpufreq_online() triggers in this case.
> > >
> > > The core cpumask can't be used to set the policy->cpus in
> > > ve_spc_cpufreq_init() anymore in case it is called via
> > > cpuhp_cpufreq_online()->cpufreq_online()->cpufreq_driver->init().
> > >
> > > An empty online() callback can be used to avoid that the init()
> > > driver function is called during CPU hotplug in so that
> > > policy->related_cpus will not be changed.
> > >
> >
> > Unlike DT based drivers, it not easy to get the fixed cpumask unless we
> > add some mechanism to extract it based on clks/OPP added. I prefer
> > this simple solution instead.
>
> I will call this a work-around for the problem and not really the
> solution, though I won't necessarily oppose it. There are cases which
> will break even with this solution.
>
I agree and that's the reason I spoke out my thought aloud here :)
> - Boot board with cpufreq driver as module.
> - Offline all CPUs except CPU0.
> - insert cpufreq driver.
> - online all CPUs.
>
Indeed, not just boot anytime since it's a module :)
> Now there is no guarantee that the last online will get the mask
> properly, if I have understood the problem well :)
>
Yes
> But yeah, who does this kind of messy work anyway :)
>
I won't bet on that ;)
> FWIW, we need a proper way (may be from architecture code) to find
> list of all CPUs that share clock line.
>
Yes but there's no architectural way. I need to revise and see tc2_pm.c
to check if we can do any magic there.
--
Regards,
Sudeep
_______________________________________________
linux-arm-kernel mailing list
linux-arm-kernel@lists.infradead.org
http://lists.infradead.org/mailman/listinfo/linux-arm-kernel
next prev parent reply other threads:[~2019-11-27 13:32 UTC|newest]
Thread overview: 22+ messages / expand[flat|nested] mbox.gz Atom feed top
2019-11-27 11:48 [PATCH] cpufreq: vexpress-spc: Fix wrong alternation of policy->related_cpus during CPU hp Dietmar Eggemann
2019-11-27 11:48 ` Dietmar Eggemann
2019-11-27 12:07 ` Viresh Kumar
2019-11-27 12:07 ` Viresh Kumar
2019-11-27 12:10 ` Sudeep Holla
2019-11-27 12:10 ` Sudeep Holla
2019-11-27 12:08 ` Sudeep Holla
2019-11-27 12:08 ` Sudeep Holla
2019-11-27 12:14 ` Viresh Kumar
2019-11-27 12:14 ` Viresh Kumar
2019-11-27 13:32 ` Sudeep Holla [this message]
2019-11-27 13:32 ` Sudeep Holla
2019-11-27 14:58 ` Dietmar Eggemann
2019-11-27 14:58 ` Dietmar Eggemann
2019-11-27 15:40 ` Sudeep Holla
2019-11-27 15:40 ` Sudeep Holla
2019-11-27 18:45 ` Sudeep Holla
2019-11-27 18:45 ` Sudeep Holla
2019-11-28 2:31 ` Viresh Kumar
2019-11-28 2:31 ` Viresh Kumar
2019-11-28 10:01 ` Dietmar Eggemann
2019-11-28 10:01 ` Dietmar Eggemann
Reply instructions:
You may reply publicly to this message via plain-text email
using any one of the following methods:
* Save the following mbox file, import it into your mail client,
and reply-to-all from there: mbox
Avoid top-posting and favor interleaved quoting:
https://en.wikipedia.org/wiki/Posting_style#Interleaved_style
* Reply using the --to, --cc, and --in-reply-to
switches of git-send-email(1):
git send-email \
--in-reply-to=20191127133200.GE29301@bogus \
--to=sudeep.holla@arm.com \
--cc=dietmar.eggemann@arm.com \
--cc=linux-arm-kernel@lists.infradead.org \
--cc=linux-kernel@vger.kernel.org \
--cc=linux-pm@vger.kernel.org \
--cc=liviu.dudau@arm.com \
--cc=lorenzo.pieralisi@arm.com \
--cc=lukasz.luba@arm.com \
--cc=morten.rasmussen@arm.com \
--cc=rjw@rjwysocki.net \
--cc=viresh.kumar@linaro.org \
/path/to/YOUR_REPLY
https://kernel.org/pub/software/scm/git/docs/git-send-email.html
* If your mail client supports setting the In-Reply-To header
via mailto: links, try the mailto: link
Be sure your reply has a Subject: header at the top and a blank line
before the message body.
This is an external index of several public inboxes,
see mirroring instructions on how to clone and mirror
all data and code used by this external index.