All of lore.kernel.org
 help / color / mirror / Atom feed
From: Vivek Goyal <vgoyal@redhat.com>
To: Max Reitz <mreitz@redhat.com>
Cc: virtio-fs-list <virtio-fs@redhat.com>,
	Miklos Szeredi <miklos@szeredi.hu>,
	qemu-devel@nongnu.org
Subject: Re: [Virtio-fs] [PATCH 1/3] virtiofsd: Find original inode ID of mount points
Date: Wed, 2 Jun 2021 14:19:58 -0400	[thread overview]
Message-ID: <20210602181958.GC115492@redhat.com> (raw)
In-Reply-To: <20210512125544.9536-2-mreitz@redhat.com>

On Wed, May 12, 2021 at 02:55:42PM +0200, Max Reitz wrote:
> Mount point directories represent two inodes: On one hand, they are a
> normal directory on their parent filesystem.  On the other, they are the
> root node of the filesystem mounted there.  Thus, they have two inode
> IDs.
> 
> Right now, we only report the latter inode ID (i.e. the inode ID of the
> mounted filesystem's root node).  This is fine once the guest has
> auto-mounted a submount there (so this inode ID goes with a device ID
> that is distinct from the parent filesystem), but before the auto-mount,
> they have the device ID of the parent and the inode ID for the submount.
> This is problematic because this is likely exactly the same
> st_dev/st_ino combination as the parent filesystem's root node.  This
> leads to problems for example with `find`, which will thus complain
> about a filesystem loop if it has visited the parent filesystem's root
> node before, and then refuse to descend into the submount.
> 
> There is a way to find the mount directory's original inode ID, and that
> is to readdir(3) the parent directory, look for the mount directory, and
> read the dirent.d_ino field.  Using this, we can let lookup and
> readdirplus return that original inode ID, which the guest will thus
> show until the submount is auto-mounted.  (Then, it will invoke getattr
> and that stat(2) call will return the inode ID for the submount.)

[ CC miklos ]

Hi Max,

Though we discussed this in chat room, I am still responding to this
email with the concern I have, so that there is a record of it.

So with this patch for FUSE_LOOKUP  we always return submount's parentinode
id and with GETATTR request we return actual inode id of submount. That
kind of bothers me a bit as we are assuming that there is always going
to be a GETATTR request after FUSE_LOOKUP. FUSE_LOOKUP itself has attrs
returned with it and it might happen that after FUSE_LOOKUP, FUSE_GETATTR
might not be called at all because FUSE_LOOKUP itself got the latest
updated attrs with certain timeout.

For example, if I call stat on a normal file (not submount), I see that
after FUSE_LOOKUP, no FUSE_GETATTR request is going and
fuse_update_get_attr() is using attrs from locally cached inode attrs.

But same thing does not seem to be happening in case of submount. Once
submount is created in guest, I see that we never seem to be calling
->revalidate() on newly created dentry of submount root. I am not sure
why. And that means we don't do FUSE_LOOKUP and that means FUSE_GETATTR
always gets called.

I am not sure if this is a bug or expected behavior. I am not confident
that we can rely on this behavior of submount dentries. 

Ccing Miklos. He might have thoughts on this.

As we discussed, may be it is a better idea to create two inodes in
virtiofsd (like we do in guest). One for submount parent and one for
actual submount.

Thanks
Vivek


> 
> Signed-off-by: Max Reitz <mreitz@redhat.com>
> ---
>  tools/virtiofsd/passthrough_ll.c | 104 +++++++++++++++++++++++++++++--
>  1 file changed, 99 insertions(+), 5 deletions(-)
> 
> diff --git a/tools/virtiofsd/passthrough_ll.c b/tools/virtiofsd/passthrough_ll.c
> index 1553d2ef45..110b6e7e5b 100644
> --- a/tools/virtiofsd/passthrough_ll.c
> +++ b/tools/virtiofsd/passthrough_ll.c
> @@ -968,14 +968,87 @@ static int do_statx(struct lo_data *lo, int dirfd, const char *pathname,
>      return 0;
>  }
>  
> +/*
> + * Use readdir() to find mp_name's inode ID on the parent's filesystem.
> + * (For mount points, stat() will only return the inode ID on the
> + * filesystem mounted there, i.e. the root directory's inode ID.  The
> + * mount point originally was a directory on the parent filesystem,
> + * though, and so has a different inode ID there.  When passing
> + * submount information to the guest, we need to pass this other ID,
> + * so the guest can use it as the inode ID until the submount is
> + * auto-mounted.  (At which point the guest will invoke getattr and
> + * find the inode ID on the submount.))
> + *
> + * Return 0 on success, and -errno otherwise.  *pino is set only in
> + * case of success.
> + */
> +static int get_mp_ino_on_parent(const struct lo_inode *dir, const char *mp_name,
> +                                ino_t *pino)
> +{
> +    int dirfd = -1;
> +    int ret;
> +    DIR *dp = NULL;
> +
> +    dirfd = openat(dir->fd, ".", O_RDONLY);
> +    if (dirfd < 0) {
> +        ret = -errno;
> +        goto out;
> +    }
> +
> +    dp = fdopendir(dirfd);
> +    if (!dp) {
> +        ret = -errno;
> +        goto out;
> +    }
> +    /* Owned by dp now */
> +    dirfd = -1;
> +
> +    while (true) {
> +        struct dirent *de;
> +
> +        errno = 0;
> +        de = readdir(dp);
> +        if (!de) {
> +            ret = errno ? -errno : -ENOENT;
> +            goto out;
> +        }
> +
> +        if (!strcmp(de->d_name, mp_name)) {
> +            *pino = de->d_ino;
> +            ret = 0;
> +            goto out;
> +        }
> +    }
> +
> +out:
> +    if (dp) {
> +        closedir(dp);
> +    }
> +    if (dirfd >= 0) {
> +        close(dirfd);
> +    }
> +    return ret;
> +}
> +
>  /*
>   * Increments nlookup on the inode on success. unref_inode_lolocked() must be
>   * called eventually to decrement nlookup again. If inodep is non-NULL, the
>   * inode pointer is stored and the caller must call lo_inode_put().
> + *
> + * If parent_fs_st_ino is true, the entry is a mount point, and submounts are
> + * announced to the guest, set e->attr.st_ino to the entry's inode ID on its
> + * parent filesystem instead of its inode ID on the filesystem mounted on it.
> + * (For mount points, the entry encompasses two inodes: One on the parent FS,
> + * and one on the mounted FS (where it is the root node), so it has two inode
> + * IDs.  When looking up entries, we should show the guest the parent FS's inode
> + * ID, because as long as the guest has not auto-mounted the submount, it should
> + * see that original ID.  Once it does perform the auto-mount, it will invoke
> + * getattr and see the root node's inode ID.)
>   */
>  static int lo_do_lookup(fuse_req_t req, fuse_ino_t parent, const char *name,
>                          struct fuse_entry_param *e,
> -                        struct lo_inode **inodep)
> +                        struct lo_inode **inodep,
> +                        bool parent_fs_st_ino)
>  {
>      int newfd;
>      int res;
> @@ -984,6 +1057,7 @@ static int lo_do_lookup(fuse_req_t req, fuse_ino_t parent, const char *name,
>      struct lo_data *lo = lo_data(req);
>      struct lo_inode *inode = NULL;
>      struct lo_inode *dir = lo_inode(req, parent);
> +    ino_t ino_id_for_guest;
>  
>      if (inodep) {
>          *inodep = NULL; /* in case there is an error */
> @@ -1018,9 +1092,22 @@ static int lo_do_lookup(fuse_req_t req, fuse_ino_t parent, const char *name,
>          goto out_err;
>      }
>  
> +    ino_id_for_guest = e->attr.st_ino;
> +
>      if (S_ISDIR(e->attr.st_mode) && lo->announce_submounts &&
>          (e->attr.st_dev != dir->key.dev || mnt_id != dir->key.mnt_id)) {
>          e->attr_flags |= FUSE_ATTR_SUBMOUNT;
> +
> +        if (parent_fs_st_ino) {
> +            /*
> +             * Best effort, so ignore errors.
> +             * Also note that using readdir() means there may be races:
> +             * The directory entry we find (if any) may be different
> +             * from newfd.  Again, this is a best effort.  Reporting
> +             * the wrong inode ID to the guest is not catastrophic.
> +             */
> +            get_mp_ino_on_parent(dir, name, &ino_id_for_guest);
> +        }
>      }
>  
>      inode = lo_find(lo, &e->attr, mnt_id);
> @@ -1043,6 +1130,10 @@ static int lo_do_lookup(fuse_req_t req, fuse_ino_t parent, const char *name,
>  
>          inode->nlookup = 1;
>          inode->fd = newfd;
> +        /*
> +         * For the inode key, use the dev/ino/mnt ID as reported by stat()
> +         * (i.e. not ino_id_for_guest)
> +         */
>          inode->key.ino = e->attr.st_ino;
>          inode->key.dev = e->attr.st_dev;
>          inode->key.mnt_id = mnt_id;
> @@ -1058,6 +1149,9 @@ static int lo_do_lookup(fuse_req_t req, fuse_ino_t parent, const char *name,
>      }
>      e->ino = inode->fuse_ino;
>  
> +    /* Report ino_id_for_guest to the guest */
> +    e->attr.st_ino = ino_id_for_guest;
> +
>      /* Transfer ownership of inode pointer to caller or drop it */
>      if (inodep) {
>          *inodep = inode;
> @@ -1104,7 +1198,7 @@ static void lo_lookup(fuse_req_t req, fuse_ino_t parent, const char *name)
>          return;
>      }
>  
> -    err = lo_do_lookup(req, parent, name, &e, NULL);
> +    err = lo_do_lookup(req, parent, name, &e, NULL, true);
>      if (err) {
>          fuse_reply_err(req, err);
>      } else {
> @@ -1217,7 +1311,7 @@ static void lo_mknod_symlink(fuse_req_t req, fuse_ino_t parent,
>          goto out;
>      }
>  
> -    saverr = lo_do_lookup(req, parent, name, &e, NULL);
> +    saverr = lo_do_lookup(req, parent, name, &e, NULL, false);
>      if (saverr) {
>          goto out;
>      }
> @@ -1714,7 +1808,7 @@ static void lo_do_readdir(fuse_req_t req, fuse_ino_t ino, size_t size,
>  
>          if (plus) {
>              if (!is_dot_or_dotdot(name)) {
> -                err = lo_do_lookup(req, ino, name, &e, NULL);
> +                err = lo_do_lookup(req, ino, name, &e, NULL, true);
>                  if (err) {
>                      goto error;
>                  }
> @@ -1936,7 +2030,7 @@ static void lo_create(fuse_req_t req, fuse_ino_t parent, const char *name,
>          goto out;
>      }
>  
> -    err = lo_do_lookup(req, parent, name, &e, &inode);
> +    err = lo_do_lookup(req, parent, name, &e, &inode, false);
>      if (err) {
>          goto out;
>      }
> -- 
> 2.31.1
> 
> 


WARNING: multiple messages have this Message-ID (diff)
From: Vivek Goyal <vgoyal@redhat.com>
To: Max Reitz <mreitz@redhat.com>
Cc: virtio-fs-list <virtio-fs@redhat.com>,
	Miklos Szeredi <miklos@szeredi.hu>,
	qemu-devel@nongnu.org, Stefan Hajnoczi <stefanha@redhat.com>,
	"Dr . David Alan Gilbert" <dgilbert@redhat.com>
Subject: Re: [PATCH 1/3] virtiofsd: Find original inode ID of mount points
Date: Wed, 2 Jun 2021 14:19:58 -0400	[thread overview]
Message-ID: <20210602181958.GC115492@redhat.com> (raw)
In-Reply-To: <20210512125544.9536-2-mreitz@redhat.com>

On Wed, May 12, 2021 at 02:55:42PM +0200, Max Reitz wrote:
> Mount point directories represent two inodes: On one hand, they are a
> normal directory on their parent filesystem.  On the other, they are the
> root node of the filesystem mounted there.  Thus, they have two inode
> IDs.
> 
> Right now, we only report the latter inode ID (i.e. the inode ID of the
> mounted filesystem's root node).  This is fine once the guest has
> auto-mounted a submount there (so this inode ID goes with a device ID
> that is distinct from the parent filesystem), but before the auto-mount,
> they have the device ID of the parent and the inode ID for the submount.
> This is problematic because this is likely exactly the same
> st_dev/st_ino combination as the parent filesystem's root node.  This
> leads to problems for example with `find`, which will thus complain
> about a filesystem loop if it has visited the parent filesystem's root
> node before, and then refuse to descend into the submount.
> 
> There is a way to find the mount directory's original inode ID, and that
> is to readdir(3) the parent directory, look for the mount directory, and
> read the dirent.d_ino field.  Using this, we can let lookup and
> readdirplus return that original inode ID, which the guest will thus
> show until the submount is auto-mounted.  (Then, it will invoke getattr
> and that stat(2) call will return the inode ID for the submount.)

[ CC miklos ]

Hi Max,

Though we discussed this in chat room, I am still responding to this
email with the concern I have, so that there is a record of it.

So with this patch for FUSE_LOOKUP  we always return submount's parentinode
id and with GETATTR request we return actual inode id of submount. That
kind of bothers me a bit as we are assuming that there is always going
to be a GETATTR request after FUSE_LOOKUP. FUSE_LOOKUP itself has attrs
returned with it and it might happen that after FUSE_LOOKUP, FUSE_GETATTR
might not be called at all because FUSE_LOOKUP itself got the latest
updated attrs with certain timeout.

For example, if I call stat on a normal file (not submount), I see that
after FUSE_LOOKUP, no FUSE_GETATTR request is going and
fuse_update_get_attr() is using attrs from locally cached inode attrs.

But same thing does not seem to be happening in case of submount. Once
submount is created in guest, I see that we never seem to be calling
->revalidate() on newly created dentry of submount root. I am not sure
why. And that means we don't do FUSE_LOOKUP and that means FUSE_GETATTR
always gets called.

I am not sure if this is a bug or expected behavior. I am not confident
that we can rely on this behavior of submount dentries. 

Ccing Miklos. He might have thoughts on this.

As we discussed, may be it is a better idea to create two inodes in
virtiofsd (like we do in guest). One for submount parent and one for
actual submount.

Thanks
Vivek


> 
> Signed-off-by: Max Reitz <mreitz@redhat.com>
> ---
>  tools/virtiofsd/passthrough_ll.c | 104 +++++++++++++++++++++++++++++--
>  1 file changed, 99 insertions(+), 5 deletions(-)
> 
> diff --git a/tools/virtiofsd/passthrough_ll.c b/tools/virtiofsd/passthrough_ll.c
> index 1553d2ef45..110b6e7e5b 100644
> --- a/tools/virtiofsd/passthrough_ll.c
> +++ b/tools/virtiofsd/passthrough_ll.c
> @@ -968,14 +968,87 @@ static int do_statx(struct lo_data *lo, int dirfd, const char *pathname,
>      return 0;
>  }
>  
> +/*
> + * Use readdir() to find mp_name's inode ID on the parent's filesystem.
> + * (For mount points, stat() will only return the inode ID on the
> + * filesystem mounted there, i.e. the root directory's inode ID.  The
> + * mount point originally was a directory on the parent filesystem,
> + * though, and so has a different inode ID there.  When passing
> + * submount information to the guest, we need to pass this other ID,
> + * so the guest can use it as the inode ID until the submount is
> + * auto-mounted.  (At which point the guest will invoke getattr and
> + * find the inode ID on the submount.))
> + *
> + * Return 0 on success, and -errno otherwise.  *pino is set only in
> + * case of success.
> + */
> +static int get_mp_ino_on_parent(const struct lo_inode *dir, const char *mp_name,
> +                                ino_t *pino)
> +{
> +    int dirfd = -1;
> +    int ret;
> +    DIR *dp = NULL;
> +
> +    dirfd = openat(dir->fd, ".", O_RDONLY);
> +    if (dirfd < 0) {
> +        ret = -errno;
> +        goto out;
> +    }
> +
> +    dp = fdopendir(dirfd);
> +    if (!dp) {
> +        ret = -errno;
> +        goto out;
> +    }
> +    /* Owned by dp now */
> +    dirfd = -1;
> +
> +    while (true) {
> +        struct dirent *de;
> +
> +        errno = 0;
> +        de = readdir(dp);
> +        if (!de) {
> +            ret = errno ? -errno : -ENOENT;
> +            goto out;
> +        }
> +
> +        if (!strcmp(de->d_name, mp_name)) {
> +            *pino = de->d_ino;
> +            ret = 0;
> +            goto out;
> +        }
> +    }
> +
> +out:
> +    if (dp) {
> +        closedir(dp);
> +    }
> +    if (dirfd >= 0) {
> +        close(dirfd);
> +    }
> +    return ret;
> +}
> +
>  /*
>   * Increments nlookup on the inode on success. unref_inode_lolocked() must be
>   * called eventually to decrement nlookup again. If inodep is non-NULL, the
>   * inode pointer is stored and the caller must call lo_inode_put().
> + *
> + * If parent_fs_st_ino is true, the entry is a mount point, and submounts are
> + * announced to the guest, set e->attr.st_ino to the entry's inode ID on its
> + * parent filesystem instead of its inode ID on the filesystem mounted on it.
> + * (For mount points, the entry encompasses two inodes: One on the parent FS,
> + * and one on the mounted FS (where it is the root node), so it has two inode
> + * IDs.  When looking up entries, we should show the guest the parent FS's inode
> + * ID, because as long as the guest has not auto-mounted the submount, it should
> + * see that original ID.  Once it does perform the auto-mount, it will invoke
> + * getattr and see the root node's inode ID.)
>   */
>  static int lo_do_lookup(fuse_req_t req, fuse_ino_t parent, const char *name,
>                          struct fuse_entry_param *e,
> -                        struct lo_inode **inodep)
> +                        struct lo_inode **inodep,
> +                        bool parent_fs_st_ino)
>  {
>      int newfd;
>      int res;
> @@ -984,6 +1057,7 @@ static int lo_do_lookup(fuse_req_t req, fuse_ino_t parent, const char *name,
>      struct lo_data *lo = lo_data(req);
>      struct lo_inode *inode = NULL;
>      struct lo_inode *dir = lo_inode(req, parent);
> +    ino_t ino_id_for_guest;
>  
>      if (inodep) {
>          *inodep = NULL; /* in case there is an error */
> @@ -1018,9 +1092,22 @@ static int lo_do_lookup(fuse_req_t req, fuse_ino_t parent, const char *name,
>          goto out_err;
>      }
>  
> +    ino_id_for_guest = e->attr.st_ino;
> +
>      if (S_ISDIR(e->attr.st_mode) && lo->announce_submounts &&
>          (e->attr.st_dev != dir->key.dev || mnt_id != dir->key.mnt_id)) {
>          e->attr_flags |= FUSE_ATTR_SUBMOUNT;
> +
> +        if (parent_fs_st_ino) {
> +            /*
> +             * Best effort, so ignore errors.
> +             * Also note that using readdir() means there may be races:
> +             * The directory entry we find (if any) may be different
> +             * from newfd.  Again, this is a best effort.  Reporting
> +             * the wrong inode ID to the guest is not catastrophic.
> +             */
> +            get_mp_ino_on_parent(dir, name, &ino_id_for_guest);
> +        }
>      }
>  
>      inode = lo_find(lo, &e->attr, mnt_id);
> @@ -1043,6 +1130,10 @@ static int lo_do_lookup(fuse_req_t req, fuse_ino_t parent, const char *name,
>  
>          inode->nlookup = 1;
>          inode->fd = newfd;
> +        /*
> +         * For the inode key, use the dev/ino/mnt ID as reported by stat()
> +         * (i.e. not ino_id_for_guest)
> +         */
>          inode->key.ino = e->attr.st_ino;
>          inode->key.dev = e->attr.st_dev;
>          inode->key.mnt_id = mnt_id;
> @@ -1058,6 +1149,9 @@ static int lo_do_lookup(fuse_req_t req, fuse_ino_t parent, const char *name,
>      }
>      e->ino = inode->fuse_ino;
>  
> +    /* Report ino_id_for_guest to the guest */
> +    e->attr.st_ino = ino_id_for_guest;
> +
>      /* Transfer ownership of inode pointer to caller or drop it */
>      if (inodep) {
>          *inodep = inode;
> @@ -1104,7 +1198,7 @@ static void lo_lookup(fuse_req_t req, fuse_ino_t parent, const char *name)
>          return;
>      }
>  
> -    err = lo_do_lookup(req, parent, name, &e, NULL);
> +    err = lo_do_lookup(req, parent, name, &e, NULL, true);
>      if (err) {
>          fuse_reply_err(req, err);
>      } else {
> @@ -1217,7 +1311,7 @@ static void lo_mknod_symlink(fuse_req_t req, fuse_ino_t parent,
>          goto out;
>      }
>  
> -    saverr = lo_do_lookup(req, parent, name, &e, NULL);
> +    saverr = lo_do_lookup(req, parent, name, &e, NULL, false);
>      if (saverr) {
>          goto out;
>      }
> @@ -1714,7 +1808,7 @@ static void lo_do_readdir(fuse_req_t req, fuse_ino_t ino, size_t size,
>  
>          if (plus) {
>              if (!is_dot_or_dotdot(name)) {
> -                err = lo_do_lookup(req, ino, name, &e, NULL);
> +                err = lo_do_lookup(req, ino, name, &e, NULL, true);
>                  if (err) {
>                      goto error;
>                  }
> @@ -1936,7 +2030,7 @@ static void lo_create(fuse_req_t req, fuse_ino_t parent, const char *name,
>          goto out;
>      }
>  
> -    err = lo_do_lookup(req, parent, name, &e, &inode);
> +    err = lo_do_lookup(req, parent, name, &e, &inode, false);
>      if (err) {
>          goto out;
>      }
> -- 
> 2.31.1
> 
> 



  parent reply	other threads:[~2021-06-02 18:19 UTC|newest]

Thread overview: 22+ messages / expand[flat|nested]  mbox.gz  Atom feed  top
2021-05-12 12:55 [PATCH 0/3] virtiofsd: Find original inode ID of mount points Max Reitz
2021-05-12 12:55 ` [PATCH 1/3] " Max Reitz
2021-05-12 15:59   ` Connor Kuehl
2021-05-17 14:57   ` [Virtio-fs] " Vivek Goyal
2021-05-17 14:57     ` Vivek Goyal
2021-05-17 17:26     ` [Virtio-fs] " Max Reitz
2021-05-17 17:26       ` Max Reitz
2021-05-20 11:28       ` [Virtio-fs] " Dr. David Alan Gilbert
2021-05-20 11:28         ` Dr. David Alan Gilbert
2021-05-26 18:13   ` [Virtio-fs] " Vivek Goyal
2021-05-26 18:13     ` Vivek Goyal
2021-05-26 18:50     ` [Virtio-fs] " Vivek Goyal
2021-05-27 15:00       ` Max Reitz
2021-06-02 18:19   ` Vivek Goyal [this message]
2021-06-02 18:19     ` Vivek Goyal
2021-06-02 18:59     ` [Virtio-fs] " Miklos Szeredi
2021-06-02 18:59       ` Miklos Szeredi
2021-06-04 16:22       ` [Virtio-fs] " Max Reitz
2021-06-04 16:22         ` Max Reitz
2021-05-12 12:55 ` [PATCH 2/3] virtiofs_submounts.py: Do not generate ssh key Max Reitz
2021-05-12 12:55 ` [PATCH 3/3] virtiofs_submounts.py: Check `find` Max Reitz
2021-05-12 14:37 ` [Virtio-fs] Fwd: [PATCH 0/3] virtiofsd: Find original inode ID of mount points Max Reitz

Reply instructions:

You may reply publicly to this message via plain-text email
using any one of the following methods:

* Save the following mbox file, import it into your mail client,
  and reply-to-all from there: mbox

  Avoid top-posting and favor interleaved quoting:
  https://en.wikipedia.org/wiki/Posting_style#Interleaved_style

* Reply using the --to, --cc, and --in-reply-to
  switches of git-send-email(1):

  git send-email \
    --in-reply-to=20210602181958.GC115492@redhat.com \
    --to=vgoyal@redhat.com \
    --cc=miklos@szeredi.hu \
    --cc=mreitz@redhat.com \
    --cc=qemu-devel@nongnu.org \
    --cc=virtio-fs@redhat.com \
    /path/to/YOUR_REPLY

  https://kernel.org/pub/software/scm/git/docs/git-send-email.html

* If your mail client supports setting the In-Reply-To header
  via mailto: links, try the mailto: link
Be sure your reply has a Subject: header at the top and a blank line before the message body.
This is an external index of several public inboxes,
see mirroring instructions on how to clone and mirror
all data and code used by this external index.