I've been working on use of the thermal assist unit to control the
temperature of G3s. A code fragment is below. This works to keep a
below-normal-spec chip at a junction temperature below the limit of 65C,
but is quite crude. In particular, I just made up the value of ICTC.
Does anyone have any suggestions for a good control stratgy for running
at constant temperature?
- Adrian Cox, AG Electronics
asmlinkage void do_THERM(struct pt_regs *regs)
{
unsigned t2 = _get_THRM2();
if (t2 & THRM1_TIN) {
int threshold = (t2 & THRM1_THRES) >> 23;
if (t2 & THRM1_TID) {
printk("Below threshold temp %d\n", threshold);
_set_THRM2(((threshold + 4) << 23) | THRM1_V | THRM1_TIE);
_set_ICTC(0);
} else {
printk("Above threshold temp %d\n", threshold);
_set_THRM2(((threshold - 4) << 23) | THRM1_TID | THRM1_V |
THRM1_TIE);
_set_ICTC(0x5);
}
_set_THRM3(0x00003f69);
} else
printk("Unexpected TAU trap at PC: %lx, SR: %lx, vector=%lx\n",
regs->nip, regs->msr, regs->trap);
}
** Sent via the linuxppc-dev mail list. See http://lists.linuxppc.org/
^ permalink raw reply [flat|nested] only message in thread
only message in thread, other threads:[~1999-12-02 17:07 UTC | newest]
Thread overview: (only message) (download: mbox.gz follow: Atom feed
-- links below jump to the message on this page --
1999-12-02 17:07 Thermal Management Adrian Cox
This is an external index of several public inboxes,
see mirroring instructions on how to clone and mirror
all data and code used by this external index.