* [lm-sensors] AMD Family 11h thermal sensor
@ 2008-09-23 20:39 Howard Chu
2008-09-23 20:41 ` Howard Chu
0 siblings, 1 reply; 2+ messages in thread
From: Howard Chu @ 2008-09-23 20:39 UTC (permalink / raw)
To: lm-sensors
The newer AMD X2 Turion (and other) processors appear to have the same thermal
monitoring capability as K10, but the PCI device IDs for the Northbridge have
changed. (1022:1303)
I added the new ID to the K10 code posted here
http://lists.lm-sensors.org/pipermail/lm-sensors/2008-April/022909.html
and it seems to be working.
See document 41256 here
http://www.amd.com/us-en/Processors/TechnicalResources/0,,30_182_739_13906,00.html
and compare section 2.10 Thermal Functions to the same text in the K10 doc
31116 here
http://www.amd.com/us-en/Processors/TechnicalResources/0,,30_182_739_15343,00.html
--
-- Howard Chu
CTO, Symas Corp. http://www.symas.com
Director, Highland Sun http://highlandsun.com/hyc/
Chief Architect, OpenLDAP http://www.openldap.org/project/
_______________________________________________
lm-sensors mailing list
lm-sensors@lm-sensors.org
http://lists.lm-sensors.org/mailman/listinfo/lm-sensors
^ permalink raw reply [flat|nested] 2+ messages in thread
* Re: [lm-sensors] AMD Family 11h thermal sensor
2008-09-23 20:39 [lm-sensors] AMD Family 11h thermal sensor Howard Chu
@ 2008-09-23 20:41 ` Howard Chu
0 siblings, 0 replies; 2+ messages in thread
From: Howard Chu @ 2008-09-23 20:41 UTC (permalink / raw)
To: lm-sensors
Howard Chu wrote:
> The newer AMD X2 Turion (and other) processors appear to have the same thermal
> monitoring capability as K10, but the PCI device IDs for the Northbridge have
> changed. (1022:1303)
>
> I added the new ID to the K10 code posted here
> http://lists.lm-sensors.org/pipermail/lm-sensors/2008-April/022909.html
> and it seems to be working.
By the way, here's the output from my HP dv5z running linux-2.6.27-rc7
root@violino:/usr/src/obj2.6.27/drivers/hwmon# sensors
acpitz-virtual-0
Adapter: Virtual device
temp1: +59.0°C (crit = +105.0°C)
k10temp-pci-00c3
Adapter: PCI adapter
temp1: +59.4°C
--
-- Howard Chu
CTO, Symas Corp. http://www.symas.com
Director, Highland Sun http://highlandsun.com/hyc/
Chief Architect, OpenLDAP http://www.openldap.org/project/
_______________________________________________
lm-sensors mailing list
lm-sensors@lm-sensors.org
http://lists.lm-sensors.org/mailman/listinfo/lm-sensors
^ permalink raw reply [flat|nested] 2+ messages in thread
end of thread, other threads:[~2008-09-23 20:41 UTC | newest]
Thread overview: 2+ messages (download: mbox.gz follow: Atom feed
-- links below jump to the message on this page --
2008-09-23 20:39 [lm-sensors] AMD Family 11h thermal sensor Howard Chu
2008-09-23 20:41 ` Howard Chu
This is an external index of several public inboxes,
see mirroring instructions on how to clone and mirror
all data and code used by this external index.