All of lore.kernel.org
 help / color / mirror / Atom feed
From: "Timothy D. Lenz" <tlenz@vorgon.com>
To: "Mathias Burén" <mathias.buren@gmail.com>
Cc: linux-raid@vger.kernel.org
Subject: Re: component device mismatches found: 9600
Date: Mon, 01 Aug 2011 16:25:47 -0700	[thread overview]
Message-ID: <4E3735FB.3080103@vorgon.com> (raw)
In-Reply-To: <CADNH=7Gr6h_4Fpn5QwwKnyJrd18EUo36tidCJJ5WrKvAMqkmog@mail.gmail.com>


vorg@x64VDR:~$ sudo smartctl -a /dev/sda
smartctl 5.41 2011-06-09 r3365 [x86_64-linux-2.6.34.20100610.1] (local 
build)
Copyright (C) 2002-11 by Bruce Allen, http://smartmontools.sourceforge.net

=== START OF INFORMATION SECTION ===
Model Family:     Seagate Barracuda 7200.11
Device Model:     ST3500320AS
Serial Number:    9QM7M86S
LU WWN Device Id: 5 000c50 01059c636
Firmware Version: SD1A
User Capacity:    500,107,862,016 bytes [500 GB]
Sector Size:      512 bytes logical/physical
Device is:        In smartctl database [for details use: -P show]
ATA Version is:   8
ATA Standard is:  ATA-8-ACS revision 4
Local Time is:    Mon Aug  1 16:11:16 2011 MST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x82) Offline data collection activity
                                         was completed without error.
                                         Auto Offline Data Collection: 
Enabled.
Self-test execution status:      (   0) The previous self-test routine 
completed
                                         without error or no self-test 
has ever
                                         been run.
Total time to complete Offline
data collection:                (  650) seconds.
Offline data collection
capabilities:                    (0x7b) SMART execute Offline immediate.
                                         Auto Offline data collection 
on/off support.
                                         Suspend Offline collection upon new
                                         command.
                                         Offline surface scan supported.
                                         Self-test supported.
                                         Conveyance Self-test supported.
                                         Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
                                         power-saving mode.
                                         Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
                                         General Purpose Logging supported.
Short self-test routine
recommended polling time:        (   1) minutes.
Extended self-test routine
recommended polling time:        ( 119) minutes.
Conveyance self-test routine
recommended polling time:        (   2) minutes.
SCT capabilities:              (0x103b) SCT Status supported.
                                         SCT Error Recovery Control 
supported.
                                         SCT Feature Control supported.
                                         SCT Data Table supported.

SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE 
UPDATED  WHEN_FAILED RAW_VALUE
   1 Raw_Read_Error_Rate     0x000f   114   100   006    Pre-fail 
Always       -       82804896
   3 Spin_Up_Time            0x0003   094   094   000    Pre-fail 
Always       -       0
   4 Start_Stop_Count        0x0032   100   100   020    Old_age 
Always       -       13
   5 Reallocated_Sector_Ct   0x0033   100   100   036    Pre-fail 
Always       -       0
   7 Seek_Error_Rate         0x000f   070   060   030    Pre-fail 
Always       -       12546791
   9 Power_On_Hours          0x0032   095   095   000    Old_age 
Always       -       4807
  10 Spin_Retry_Count        0x0013   100   100   097    Pre-fail 
Always       -       0
  12 Power_Cycle_Count       0x0032   100   100   020    Old_age 
Always       -       13
184 End-to-End_Error        0x0032   100   100   099    Old_age   Always 
       -       0
187 Reported_Uncorrect      0x0032   100   100   000    Old_age   Always 
       -       0
188 Command_Timeout         0x0032   100   100   000    Old_age   Always 
       -       0
189 High_Fly_Writes         0x003a   100   100   000    Old_age   Always 
       -       0
190 Airflow_Temperature_Cel 0x0022   067   065   045    Old_age   Always 
       -       33 (Min/Max 30/34)
194 Temperature_Celsius     0x0022   033   040   000    Old_age   Always 
       -       33 (0 21 0 0)
195 Hardware_ECC_Recovered  0x001a   054   033   000    Old_age   Always 
       -       82804896
197 Current_Pending_Sector  0x0012   100   100   000    Old_age   Always 
       -       0
198 Offline_Uncorrectable   0x0010   100   100   000    Old_age 
Offline      -       0
199 UDMA_CRC_Error_Count    0x003e   200   200   000    Old_age   Always 
       -       0

SMART Error Log Version: 1
No Errors Logged

SMART Self-test log structure revision number 1
No self-tests have been logged.  [To run self-tests, use: smartctl -t]


SMART Selective self-test log data structure revision number 1
  SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
     1        0        0  Not_testing
     2        0        0  Not_testing
     3        0        0  Not_testing
     4        0        0  Not_testing
     5        0        0  Not_testing
Selective self-test flags (0x0):
   After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
-------------------------------------------------------------------------------------------
vorg@x64VDR:~$ sudo smartctl -a /dev/sdb
smartctl 5.41 2011-06-09 r3365 [x86_64-linux-2.6.34.20100610.1] (local 
build)
Copyright (C) 2002-11 by Bruce Allen, http://smartmontools.sourceforge.net

=== START OF INFORMATION SECTION ===
Model Family:     Seagate Barracuda 7200.11
Device Model:     ST3500320AS
Serial Number:    9QM1P092
LU WWN Device Id: 5 000c50 0098f53ba
Firmware Version: SD15
User Capacity:    500,107,862,016 bytes [500 GB]
Sector Size:      512 bytes logical/physical
Device is:        In smartctl database [for details use: -P show]
ATA Version is:   8
ATA Standard is:  ATA-8-ACS revision 4
Local Time is:    Mon Aug  1 16:12:14 2011 MST

==> WARNING: There are known problems with these drives,
AND THIS FIRMWARE VERSION IS AFFECTED,
see the following Seagate web pages:
http://seagate.custkb.com/seagate/crm/selfservice/search.jsp?DocId=207931
http://seagate.custkb.com/seagate/crm/selfservice/search.jsp?DocId=207951

SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x82) Offline data collection activity
                                         was completed without error.
                                         Auto Offline Data Collection: 
Enabled.
Self-test execution status:      (   0) The previous self-test routine 
completed
                                         without error or no self-test 
has ever
                                         been run.
Total time to complete Offline
data collection:                (  625) seconds.
Offline data collection
capabilities:                    (0x7b) SMART execute Offline immediate.
                                         Auto Offline data collection 
on/off support.
                                         Suspend Offline collection upon new
                                         command.
                                         Offline surface scan supported.
                                         Self-test supported.
                                         Conveyance Self-test supported.
                                         Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
                                         power-saving mode.
                                         Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
                                         General Purpose Logging supported.
Short self-test routine
recommended polling time:        (   1) minutes.
Extended self-test routine
recommended polling time:        ( 113) minutes.
Conveyance self-test routine
recommended polling time:        (   2) minutes.
SCT capabilities:              (0x103b) SCT Status supported.
                                         SCT Error Recovery Control 
supported.
                                         SCT Feature Control supported.
                                         SCT Data Table supported.

SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE 
UPDATED  WHEN_FAILED RAW_VALUE
   1 Raw_Read_Error_Rate     0x000f   113   099   006    Pre-fail 
Always       -       52352187
   3 Spin_Up_Time            0x0003   094   094   000    Pre-fail 
Always       -       0
   4 Start_Stop_Count        0x0032   100   100   020    Old_age 
Always       -       39
   5 Reallocated_Sector_Ct   0x0033   100   100   036    Pre-fail 
Always       -       0
   7 Seek_Error_Rate         0x000f   078   060   030    Pre-fail 
Always       -       64855982
   9 Power_On_Hours          0x0032   072   072   000    Old_age 
Always       -       24685
  10 Spin_Retry_Count        0x0013   100   100   097    Pre-fail 
Always       -       0
  12 Power_Cycle_Count       0x0032   100   037   020    Old_age 
Always       -       39
184 End-to-End_Error        0x0032   100   100   099    Old_age   Always 
       -       0
187 Reported_Uncorrect      0x0032   100   100   000    Old_age   Always 
       -       0
188 Command_Timeout         0x0032   100   098   000    Old_age   Always 
       -       20
189 High_Fly_Writes         0x003a   100   100   000    Old_age   Always 
       -       0
190 Airflow_Temperature_Cel 0x0022   066   062   045    Old_age   Always 
       -       34 (Min/Max 30/35)
194 Temperature_Celsius     0x0022   034   040   000    Old_age   Always 
       -       34 (0 22 0 0)
195 Hardware_ECC_Recovered  0x001a   029   023   000    Old_age   Always 
       -       52352187
197 Current_Pending_Sector  0x0012   100   100   000    Old_age   Always 
       -       0
198 Offline_Uncorrectable   0x0010   100   100   000    Old_age 
Offline      -       0
199 UDMA_CRC_Error_Count    0x003e   200   200   000    Old_age   Always 
       -       0

SMART Error Log Version: 1
No Errors Logged

SMART Self-test log structure revision number 1
No self-tests have been logged.  [To run self-tests, use: smartctl -t]


SMART Selective self-test log data structure revision number 1
  SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
     1        0        0  Not_testing
     2        0        0  Not_testing
     3        0        0  Not_testing
     4        0        0  Not_testing
     5        0        0  Not_testing
Selective self-test flags (0x0):
   After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
-------------------------------------------------------------------------------------------
vorg@x64VDR:~$ sudo smartctl -a /dev/sdc
smartctl 5.41 2011-06-09 r3365 [x86_64-linux-2.6.34.20100610.1] (local 
build)
Copyright (C) 2002-11 by Bruce Allen, http://smartmontools.sourceforge.net

=== START OF INFORMATION SECTION ===
Model Family:     Seagate Barracuda 7200.11
Device Model:     ST3500320AS
Serial Number:    9QM35MY5
LU WWN Device Id: 5 000c50 00b9fbd80
Firmware Version: SD15
User Capacity:    500,107,862,016 bytes [500 GB]
Sector Size:      512 bytes logical/physical
Device is:        In smartctl database [for details use: -P show]
ATA Version is:   8
ATA Standard is:  ATA-8-ACS revision 4
Local Time is:    Mon Aug  1 16:13:15 2011 MST

==> WARNING: There are known problems with these drives,
AND THIS FIRMWARE VERSION IS AFFECTED,
see the following Seagate web pages:
http://seagate.custkb.com/seagate/crm/selfservice/search.jsp?DocId=207931
http://seagate.custkb.com/seagate/crm/selfservice/search.jsp?DocId=207951

SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x82) Offline data collection activity
                                         was completed without error.
                                         Auto Offline Data Collection: 
Enabled.
Self-test execution status:      (   0) The previous self-test routine 
completed
                                         without error or no self-test 
has ever
                                         been run.
Total time to complete Offline
data collection:                (  634) seconds.
Offline data collection
capabilities:                    (0x7b) SMART execute Offline immediate.
                                         Auto Offline data collection 
on/off support.
                                         Suspend Offline collection upon new
                                         command.
                                         Offline surface scan supported.
                                         Self-test supported.
                                         Conveyance Self-test supported.
                                         Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
                                         power-saving mode.
                                         Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
                                         General Purpose Logging supported.
Short self-test routine
recommended polling time:        (   1) minutes.
Extended self-test routine
recommended polling time:        ( 113) minutes.
Conveyance self-test routine
recommended polling time:        (   2) minutes.
SCT capabilities:              (0x103b) SCT Status supported.
                                         SCT Error Recovery Control 
supported.
                                         SCT Feature Control supported.
                                         SCT Data Table supported.

SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE 
UPDATED  WHEN_FAILED RAW_VALUE
   1 Raw_Read_Error_Rate     0x000f   119   099   006    Pre-fail 
Always       -       220520828
   3 Spin_Up_Time            0x0003   094   094   000    Pre-fail 
Always       -       0
   4 Start_Stop_Count        0x0032   100   100   020    Old_age 
Always       -       39
   5 Reallocated_Sector_Ct   0x0033   100   100   036    Pre-fail 
Always       -       0
   7 Seek_Error_Rate         0x000f   074   060   030    Pre-fail 
Always       -       8642691180
   9 Power_On_Hours          0x0032   072   072   000    Old_age 
Always       -       24685
  10 Spin_Retry_Count        0x0013   100   100   097    Pre-fail 
Always       -       0
  12 Power_Cycle_Count       0x0032   100   100   020    Old_age 
Always       -       39
184 End-to-End_Error        0x0032   100   100   099    Old_age   Always 
       -       0
187 Reported_Uncorrect      0x0032   100   100   000    Old_age   Always 
       -       0
188 Command_Timeout         0x0032   100   100   000    Old_age   Always 
       -       0
189 High_Fly_Writes         0x003a   100   100   000    Old_age   Always 
       -       0
190 Airflow_Temperature_Cel 0x0022   066   061   045    Old_age   Always 
       -       34 (Min/Max 30/36)
194 Temperature_Celsius     0x0022   034   040   000    Old_age   Always 
       -       34 (0 22 0 0)
195 Hardware_ECC_Recovered  0x001a   028   021   000    Old_age   Always 
       -       220520828
197 Current_Pending_Sector  0x0012   100   100   000    Old_age   Always 
       -       0
198 Offline_Uncorrectable   0x0010   100   100   000    Old_age 
Offline      -       0
199 UDMA_CRC_Error_Count    0x003e   200   200   000    Old_age   Always 
       -       0

SMART Error Log Version: 1
No Errors Logged

SMART Self-test log structure revision number 1
No self-tests have been logged.  [To run self-tests, use: smartctl -t]


SMART Selective self-test log data structure revision number 1
  SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
     1        0        0  Not_testing
     2        0        0  Not_testing
     3        0        0  Not_testing
     4        0        0  Not_testing
     5        0        0  Not_testing
Selective self-test flags (0x0):
   After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
-------------------------------------------------------------------------------------------
vorg@x64VDR:~$ sudo smartctl -a /dev/sdd
smartctl 5.41 2011-06-09 r3365 [x86_64-linux-2.6.34.20100610.1] (local 
build)
Copyright (C) 2002-11 by Bruce Allen, http://smartmontools.sourceforge.net

=== START OF INFORMATION SECTION ===
Model Family:     Seagate Barracuda 7200.11
Device Model:     ST3500820AS
Serial Number:    9QM6V6JF
LU WWN Device Id: 5 000c50 009cb8c4c
Firmware Version: SD1A
User Capacity:    500,107,862,016 bytes [500 GB]
Sector Size:      512 bytes logical/physical
Device is:        In smartctl database [for details use: -P show]
ATA Version is:   8
ATA Standard is:  ATA-8-ACS revision 4
Local Time is:    Mon Aug  1 16:14:04 2011 MST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x82) Offline data collection activity
                                         was completed without error.
                                         Auto Offline Data Collection: 
Enabled.
Self-test execution status:      (   0) The previous self-test routine 
completed
                                         without error or no self-test 
has ever
                                         been run.
Total time to complete Offline
data collection:                (  634) seconds.
Offline data collection
capabilities:                    (0x7b) SMART execute Offline immediate.
                                         Auto Offline data collection 
on/off support.
                                         Suspend Offline collection upon new
                                         command.
                                         Offline surface scan supported.
                                         Self-test supported.
                                         Conveyance Self-test supported.
                                         Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
                                         power-saving mode.
                                         Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
                                         General Purpose Logging supported.
Short self-test routine
recommended polling time:        (   1) minutes.
Extended self-test routine
recommended polling time:        ( 114) minutes.
Conveyance self-test routine
recommended polling time:        (   2) minutes.
SCT capabilities:              (0x103b) SCT Status supported.
                                         SCT Error Recovery Control 
supported.
                                         SCT Feature Control supported.
                                         SCT Data Table supported.

SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE 
UPDATED  WHEN_FAILED RAW_VALUE
   1 Raw_Read_Error_Rate     0x000f   119   099   006    Pre-fail 
Always       -       205159952
   3 Spin_Up_Time            0x0003   094   094   000    Pre-fail 
Always       -       0
   4 Start_Stop_Count        0x0032   100   100   020    Old_age 
Always       -       34
   5 Reallocated_Sector_Ct   0x0033   100   100   036    Pre-fail 
Always       -       0
   7 Seek_Error_Rate         0x000f   072   060   030    Pre-fail 
Always       -       15541587
   9 Power_On_Hours          0x0032   088   088   000    Old_age 
Always       -       10726
  10 Spin_Retry_Count        0x0013   100   100   097    Pre-fail 
Always       -       0
  12 Power_Cycle_Count       0x0032   100   100   020    Old_age 
Always       -       34
184 End-to-End_Error        0x0032   100   100   099    Old_age   Always 
       -       0
187 Reported_Uncorrect      0x0032   100   100   000    Old_age   Always 
       -       0
188 Command_Timeout         0x0032   100   100   000    Old_age   Always 
       -       0
189 High_Fly_Writes         0x003a   100   100   000    Old_age   Always 
       -       0
190 Airflow_Temperature_Cel 0x0022   065   062   045    Old_age   Always 
       -       35 (Min/Max 30/37)
194 Temperature_Celsius     0x0022   035   040   000    Old_age   Always 
       -       35 (0 23 0 0)
195 Hardware_ECC_Recovered  0x001a   049   023   000    Old_age   Always 
       -       205159952
197 Current_Pending_Sector  0x0012   100   100   000    Old_age   Always 
       -       0
198 Offline_Uncorrectable   0x0010   100   100   000    Old_age 
Offline      -       0
199 UDMA_CRC_Error_Count    0x003e   200   200   000    Old_age   Always 
       -       0

SMART Error Log Version: 1
No Errors Logged

SMART Self-test log structure revision number 1
No self-tests have been logged.  [To run self-tests, use: smartctl -t]


SMART Selective self-test log data structure revision number 1
  SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
     1        0        0  Not_testing
     2        0        0  Not_testing
     3        0        0  Not_testing
     4        0        0  Not_testing
     5        0        0  Not_testing
Selective self-test flags (0x0):
   After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
-------------------------------------------------------------------------------------------


On 8/1/2011 12:49 PM, Mathias Burén wrote:
> On 1 August 2011 20:44, Timothy D. Lenz<tlenz@vorgon.com>  wrote:
>>
>> Don't think I have smartctl installed. Tried with/out sudo
>>   vorg@x64VDR:~$ smartctl -a /dev/sda
>>   -bash: smartctl: command not found
>
> So install it, or compile it from source and run it (smartmontools).
> It would be interesting to see if you have a problem with
> HDDs/controllers/backplanes/cables.
>
> /M
>
--
To unsubscribe from this list: send the line "unsubscribe linux-raid" in
the body of a message to majordomo@vger.kernel.org
More majordomo info at  http://vger.kernel.org/majordomo-info.html

  reply	other threads:[~2011-08-01 23:25 UTC|newest]

Thread overview: 6+ messages / expand[flat|nested]  mbox.gz  Atom feed  top
2011-07-31 18:24 component device mismatches found: 9600 Timothy D. Lenz
2011-07-31 18:32 ` Mathias Burén
2011-08-01 19:44   ` Timothy D. Lenz
2011-08-01 19:49     ` Mathias Burén
2011-08-01 23:25       ` Timothy D. Lenz [this message]
2011-08-02  0:35     ` John Robinson

Reply instructions:

You may reply publicly to this message via plain-text email
using any one of the following methods:

* Save the following mbox file, import it into your mail client,
  and reply-to-all from there: mbox

  Avoid top-posting and favor interleaved quoting:
  https://en.wikipedia.org/wiki/Posting_style#Interleaved_style

* Reply using the --to, --cc, and --in-reply-to
  switches of git-send-email(1):

  git send-email \
    --in-reply-to=4E3735FB.3080103@vorgon.com \
    --to=tlenz@vorgon.com \
    --cc=linux-raid@vger.kernel.org \
    --cc=mathias.buren@gmail.com \
    /path/to/YOUR_REPLY

  https://kernel.org/pub/software/scm/git/docs/git-send-email.html

* If your mail client supports setting the In-Reply-To header
  via mailto: links, try the mailto: link
Be sure your reply has a Subject: header at the top and a blank line before the message body.
This is an external index of several public inboxes,
see mirroring instructions on how to clone and mirror
all data and code used by this external index.