* No D-Bus Reply to Activating Context
@ 2014-02-11 12:32 Brian Ruptash
2014-02-11 17:18 ` Denis Kenzior
0 siblings, 1 reply; 3+ messages in thread
From: Brian Ruptash @ 2014-02-11 12:32 UTC (permalink / raw)
To: ofono
[-- Attachment #1: Type: text/plain, Size: 2815 bytes --]
I'm having a spurious problem where the D-Bus error reply to a context
activation isn't being sent back. This is happenning in the following
sequence, where registration is lost while in the midst of activating the
context. Not like I can recreate this, but I've received a log from an
occurance in the field. I'm running ofono 1.12 with a Cinterion PH8-P
driver that I wrote.
Here's a trace of the relevant sequence. I should receive a D-Bus reply
from the last line's pri_activate_callback() but I don't. Does anyone see
anything odd here, and any reason why the reply wouldn't be being sent?
Thanks.
09:20:42.300 gprs-context.c:317 at_gprs_activate_primary cid 1
09:20:42.302 ph8.c:122 ph8_debug Mdm: >
AT+CGDCONT=1,"IP","xxxxxxxx"\r
09:20:42.531 ph8.c:122 ph8_debug App: < \r\n+CGREG:
0\r\n\r\n+CREG: 0\r\n\r\n+CIEV: psinfo,6\r\n
09:20:42.531 gprs.c:2148 ofono_gprs_status_notify /ph8_1
status 0
09:20:42.533 network.c:1349 ofono_netreg_status_notify /ph8_1
status 0 tech -1
09:20:42.536 network.c:1219 current_operator_callback 0x128198,
0x1260b8
09:20:42.540 gprs.c:1606 netreg_status_changed 0
09:20:42.540 gprs.c:1606 netreg_status_changed 0
09:20:42.540 network-registration.c:2134 ph8_handle_sind_ciev tech 2
09:20:42.541 gprs.c:340 ph8_ciev_notify bearer 3 (umts)
09:20:42.542 ph8.c:208 ciev_notify
09:20:42.543 ph8.c:122 ph8_debug App: > AT+CGATT=0\r
09:20:42.581 ph8.c:122 ph8_debug Mdm: < \r\nOK\r\n
09:20:42.581 gprs-context.c:281 at_cgdcont_cb ok 1
09:20:42.581 ph8.c:122 ph8_debug App: < \r\nOK\r\n
09:20:42.581 gprs.c:1545 gprs_attach_callback /ph8_1 error =
0
09:20:42.581 ph8.c:122 ph8_debug Mdm: >
AT+CGDATA="PPP",1\r
09:20:42.582 ph8.c:122 ph8_debug App: > AT+CGREG?\r
09:20:42.591 ph8.c:122 ph8_debug App: < \r\n+CGREG:
1,0\r\n\r\nOK\r\n
09:20:42.591 gprs.c:1526 registration_status_cb /ph8_1 error
0 status 0
09:20:42.591 gprs.c:2148 ofono_gprs_status_notify /ph8_1
status 0
09:20:42.611 ph8.c:122 ph8_debug Mdm: < \r\nNO CARRIER\r\n
09:20:42.611 gprs-context.c:258 at_cgdata_cb Unable to enter data
state
09:20:42.611 gprs-context.c:266 at_cgdata_cb not ok, <NO CARRIER>,
error 5/0
09:20:42.611 gprs.c:859 pri_activate_callback 0x12c980 -
error 5/0
09:20:42.611 gprs.c:863 pri_activate_callback Activating
context failed with error: Unknown error type
-- Brian
[-- Attachment #2: attachment.html --]
[-- Type: text/html, Size: 7373 bytes --]
^ permalink raw reply [flat|nested] 3+ messages in thread
* Re: No D-Bus Reply to Activating Context
2014-02-11 12:32 No D-Bus Reply to Activating Context Brian Ruptash
@ 2014-02-11 17:18 ` Denis Kenzior
2014-02-17 8:40 ` Brian Ruptash
0 siblings, 1 reply; 3+ messages in thread
From: Denis Kenzior @ 2014-02-11 17:18 UTC (permalink / raw)
To: ofono
[-- Attachment #1: Type: text/plain, Size: 577 bytes --]
Hi Brian,
> 09:20:42.611 gprs.c:863 pri_activate_callback
> Activating context failed with error: Unknown error type
>
Looking at that line, we are sending a reply right after printing the
message. In case the message is NULL, you'd most likely crash inside
D-Bus or get an assertion of some kind.
The pending variable is also not messed with anywhere else, so you
should be getting a reply.
The only thing I can suggest is to try and simulate this behavior with
phonesim and see if you can duplicate / debug it.
Regards,
-Denis
^ permalink raw reply [flat|nested] 3+ messages in thread
* RE: No D-Bus Reply to Activating Context
2014-02-11 17:18 ` Denis Kenzior
@ 2014-02-17 8:40 ` Brian Ruptash
0 siblings, 0 replies; 3+ messages in thread
From: Brian Ruptash @ 2014-02-17 8:40 UTC (permalink / raw)
To: ofono
[-- Attachment #1: Type: text/plain, Size: 1203 bytes --]
> > 09:20:42.611 gprs.c:863 pri_activate_callback
> > Activating context failed with error: Unknown error type
>
> Looking at that line, we are sending a reply right after printing the
> message. In case the message is NULL, you'd most likely crash inside
> D-Bus or get an assertion of some kind.
>
> The pending variable is also not messed with anywhere else, so you
> should be getting a reply.
>
> The only thing I can suggest is to try and simulate this behavior with
> phonesim and see if you can duplicate / debug it.
I traced the log and code and agree, which is why I can't understand why
the D-Bus reply is either not sent or perhaps not received, though it
only occurs in this particular sequence and is the only case a method
return is ever "lost". dbus has a bug in that dbus-monitor can't trace
method returns, so I can't easily see what's happenning especially as
it's quite sporadic.
So I punted... I upgraded from ofono 1.12 to 1.14 which has a significant
overhaul to gdbus, though I can't find anything in the ofono mailing list
that explains what or why. And I'll see if the issue persists.
> Regards,
> -Denis
Thanks, Denis.
-- Brian
^ permalink raw reply [flat|nested] 3+ messages in thread
end of thread, other threads:[~2014-02-17 8:40 UTC | newest]
Thread overview: 3+ messages (download: mbox.gz follow: Atom feed
-- links below jump to the message on this page --
2014-02-11 12:32 No D-Bus Reply to Activating Context Brian Ruptash
2014-02-11 17:18 ` Denis Kenzior
2014-02-17 8:40 ` Brian Ruptash
This is an external index of several public inboxes,
see mirroring instructions on how to clone and mirror
all data and code used by this external index.