* [Bug 1110] i40e: runtime Rx/Tx queue setup is unusable
@ 2022-10-19 8:54 bugzilla
0 siblings, 0 replies; only message in thread
From: bugzilla @ 2022-10-19 8:54 UTC (permalink / raw)
To: dev
https://bugs.dpdk.org/show_bug.cgi?id=1110
Bug ID: 1110
Summary: i40e: runtime Rx/Tx queue setup is unusable
Product: DPDK
Version: unspecified
Hardware: All
OS: All
Status: UNCONFIRMED
Severity: normal
Priority: Normal
Component: ethdev
Assignee: dev@dpdk.org
Reporter: ivan.malov@oktetlabs.ru
Target Milestone: ---
Created attachment 225
--> https://bugs.dpdk.org/attachment.cgi?id=225&action=edit
probable-fix
Results that have been collected by an ethdev testing tool, [1], which is
opensource, suggest that i40e PMD might have a bug in runtime queue setup.
According to log [2], if a Tx queue has not been set up, starting the device
will
fail. Apparently, the driver does not take the runtime setup feature into
account
when queues are started in a loop. The proposed fix shows the gist of the
problem.
The said bug also manifests itself with regard to Rx queues.
[1] http://mails.dpdk.org/archives/dev/2022-October/251663.html
[2] https://ts-factory.io/bublik/v2/log/123183?focusId=123948&mode=treeAndlog
--
You are receiving this mail because:
You are the assignee for the bug.
^ permalink raw reply [flat|nested] only message in thread
only message in thread, other threads:[~2022-10-19 8:54 UTC | newest]
Thread overview: (only message) (download: mbox.gz follow: Atom feed
-- links below jump to the message on this page --
2022-10-19 8:54 [Bug 1110] i40e: runtime Rx/Tx queue setup is unusable bugzilla
This is an external index of several public inboxes,
see mirroring instructions on how to clone and mirror
all data and code used by this external index.