* [dpdk-dev] [Bug 702] [dpdk-21.05] perf_vm2vm_virtio_net_perf/test_vm2vm_split_ring_iperf_with_tso: vm can't forward big packets
@ 2021-05-12  3:25 bugzilla
  0 siblings, 0 replies; only message in thread
From: bugzilla @ 2021-05-12  3:25 UTC (permalink / raw)
  To: dev

https://bugs.dpdk.org/show_bug.cgi?id=702

            Bug ID: 702
           Summary: [dpdk-21.05]
                    perf_vm2vm_virtio_net_perf/test_vm2vm_split_ring_iperf
                    _with_tso: vm can't forward big packets
           Product: DPDK
           Version: unspecified
          Hardware: All
                OS: All
            Status: UNCONFIRMED
          Severity: normal
          Priority: Normal
         Component: vhost/virtio
          Assignee: dev@dpdk.org
          Reporter: weix.ling@intel.com
  Target Milestone: ---

Environment

DPDK version: 
 21.05-rc2:47a0c2e11712fc5286d6a197d549817ae8f8f50e
Other software versions: N/A
OS: Ubuntu 20.04.1 LTS/Linux 5.11.6-051106-generic
Compiler: gcc version 9.3.0 (Ubuntu 9.3.0-17ubuntu1~20.04)
Hardware platform: Intel(R) Xeon(R) Platinum 8280M CPU @ 2.70GHz
NIC hardware: Intel Corporation Ethernet Controller XL710 for 40GbE QSFP+ (rev
01)
NIC driver & firmware: i40e-5.11.6-051106-generic/8.30 0x8000a4ae 1.2926.0


Test Setup
Steps to reproduce
List the steps to reproduce the issue.

# 1. Bind NIC to DPDK
dpdk-devbind.py --force --bind=vfio-pci 0000:af:00.0 0000:af:00.1

# 2. Build DPDK
CC=gcc meson -Denable_kmods=True -Dlibdir=lib  --default-library=static
x86_64-native-linuxapp-gcc
ninja -C x86_64-native-linuxapp-gcc

# 3.Start vhost testpmd
x86_64-native-linuxapp-gcc/app/dpdk-testpmd -l
28,29,30,31,32,33,34,35,36,37,38,39,40,41,42,43,44,45,46,47,48,49,50,51,52,53,54,55,84,85,86,87,88,89,90,91,92,93,94,95,96,97,98,99,100,101,102,103,104,105,106,107,108,109,110,111
-n 4   --file-prefix=vhost_49626_20210512103940 --no-pci --vdev
'net_vhost0,iface=/root/dpdk/vhost-net0,queues=1' --vdev
'net_vhost1,iface=/root/dpdk/vhost-net1,queues=1'  -- -i --nb-cores=2
--txd=1024 --rxd=1024

start

#4. Start VM0
taskset -c 46,47,48,49,50,51,52,53 /home/QEMU/qemu-4.2.1/bin/qemu-system-x86_64
 -name vm0 -enable-kvm -pidfile /tmp/.vm0.pid -daemonize -monitor
unix:/tmp/vm0_monitor.sock,server,nowait -netdev
user,id=nttsip1,hostfwd=tcp:10.240.183.220:6000-:22 -device
e1000,netdev=nttsip1  -chardev socket,id=char0,path=/root/dpdk/vhost-net0
-netdev type=vhost-user,id=netdev0,chardev=char0,vhostforce -device
virtio-net-pci,netdev=netdev0,mac=52:54:00:00:00:01,mrg_rxbuf=off,csum=on,guest_csum=on,host_tso4=on,guest_tso4=on,guest_ecn=on
-cpu host -smp 8 -m 8192 -object
memory-backend-file,id=mem,size=8192M,mem-path=/mnt/huge,share=on -numa
node,memdev=mem -mem-prealloc -chardev
socket,path=/tmp/vm0_qga0.sock,server,nowait,id=vm0_qga0 -device virtio-serial
-device virtserialport,chardev=vm0_qga0,name=org.qemu.guest_agent.0 -vnc :4
-drive file=/home/image/ubuntu2004.img

# 5.Start VM1
taskset -c 102,103,104,105,106,107,108,109
/home/QEMU/qemu-4.2.1/bin/qemu-system-x86_64  -name vm1 -enable-kvm -pidfile
/tmp/.vm1.pid -daemonize -monitor unix:/tmp/vm1_monitor.sock,server,nowait
-device e1000,netdev=nttsip1  -netdev
user,id=nttsip1,hostfwd=tcp:10.240.183.220:6001-:22 -chardev
socket,id=char0,path=/root/dpdk/vhost-net1 -netdev
type=vhost-user,id=netdev0,chardev=char0,vhostforce -device
virtio-net-pci,netdev=netdev0,mac=52:54:00:00:00:02,mrg_rxbuf=off,csum=on,guest_csum=on,host_tso4=on,guest_tso4=on,guest_ecn=on
-cpu host -smp 8 -m 8192 -object
memory-backend-file,id=mem,size=8192M,mem-path=/mnt/huge,share=on -numa
node,memdev=mem -mem-prealloc -chardev
socket,path=/tmp/vm1_qga0.sock,server,nowait,id=vm1_qga0 -device virtio-serial
-device virtserialport,chardev=vm1_qga0,name=org.qemu.guest_agent.0 -vnc :5
-drive file=/home/image/ubuntu2004_2.img

# 6.Config ipaddress in VM0 and VM1
ifconfig ens4 up
ifconfig ens4 1.1.1.2

ifconfig ens4 up
ifconfig ens4 1.1.1.3

# 8.Send ARP in VM0 and VM1
arp -s 1.1.1.3 52:54:00:00:00:02

arp -s 1.1.1.2 52:54:00:00:00:01

# 9. Send ICMP packet from VM0 to VM1
ping 1.1.1.3 -c 4

# 10. Use iperf tools to test big packet in VM0 and VM1 to get throughput

 iperf -s -i 1    //in VM0

 iperf -c 1.1.1.2 -i 1 -t 60   //in VM1


Show the output from the previous commands.

# Put output in a noformat block like this.
root@vmubuntu2004:~# ping 1.1.1.3 -c 4
PING 1.1.1.3 (1.1.1.3) 56(84) bytes of data.
64 bytes from 1.1.1.3: icmp_seq=1 ttl=64 time=0.049 ms
64 bytes from 1.1.1.3: icmp_seq=2 ttl=64 time=0.062 ms
64 bytes from 1.1.1.3: icmp_seq=3 ttl=64 time=0.061 ms
64 bytes from 1.1.1.3: icmp_seq=4 ttl=64 time=0.061 ms
--- 1.1.1.3 ping statistics ---
4 packets transmitted, 4 received, 0% packet loss, time 3061ms
rtt min/avg/max/mdev = 0.049/0.058/0.062/0.005 ms
root@vmubuntu2004:~#

root@vmubuntu2004:~# iperf -s -i 1
------------------------------------------------------------
Server listening on TCP port 5001
TCP window size:  128 KByte (default)
------------------------------------------------------------

root@vmubuntu2004:~/dpdk# iperf -c 1.1.1.2 -i 1 -t 60



Expected Result
Explain what is the expected result in text or as an example output:

root@vmubuntu2004:~# iperf -s -i 1
------------------------------------------------------------
Server listening on TCP port 5001
TCP window size: 85.3 KByte (default)
------------------------------------------------------------
[  4] local 10.240.183.217 port 5001 connected with 10.240.183.213 port 40892
[ ID] Interval       Transfer     Bandwidth
[  4]  0.0- 1.0 sec   112 MBytes   941 Mbits/sec
[  4]  1.0- 2.0 sec   112 MBytes   941 Mbits/sec
[  4]  2.0- 3.0 sec   112 MBytes   941 Mbits/sec
[  4]  3.0- 4.0 sec   112 MBytes   942 Mbits/sec
[  4]  4.0- 5.0 sec   112 MBytes   941 Mbits/sec
[  4]  5.0- 6.0 sec   112 MBytes   942 Mbits/sec

root@vmubuntu2004:~# iperf -c 1.1.1.2 -i 1 -t 60
------------------------------------------------------------
Client connecting to 10.240.183.217, TCP port 5001
TCP window size: 85.0 KByte (default)
------------------------------------------------------------
[  3] local 10.240.183.213 port 40892 connected with 10.240.183.217 port 5001
[ ID] Interval       Transfer     Bandwidth
[  3]  0.0- 1.0 sec   114 MBytes   953 Mbits/sec
[  3]  1.0- 2.0 sec   113 MBytes   947 Mbits/sec
[  3]  2.0- 3.0 sec   112 MBytes   938 Mbits/sec
[  3]  3.0- 4.0 sec   112 MBytes   943 Mbits/sec


Regression
Is this issue a regression: (Y/N) Y

Version the regression was introduced: Specify git id if known.

commit ca7036b4af3a82d258cca914e71171434b3d0320
Author: David Marchand <david.marchand@redhat.com>
Date: Mon May 3 18:43:44 2021 +0200

vhost: fix offload flags in Rx path

The vhost library currently configures Tx offloading (PKT_TX_*) on any
packet received from a guest virtio device which asks for some offloading.

This is problematic, as Tx offloading is something that the application
must ask for: the application needs to configure devices
to support every used offloads (ip, tcp checksumming, tso..), and the
various l2/l3/l4 lengths must be set following any processing that
happened in the application itself.

On the other hand, the received packets are not marked wrt current
packet l3/l4 checksumming info.

Copy virtio rx processing to fix those offload flags with some
differences:

accept VIRTIO_NET_HDR_GSO_ECN and VIRTIO_NET_HDR_GSO_UDP,
ignore anything but the VIRTIO_NET_HDR_F_NEEDS_CSUM flag (to comply with
the virtio spec),
Some applications might rely on the current behavior, so it is left
untouched by default.
A new RTE_VHOST_USER_NET_COMPLIANT_OL_FLAGS flag is added to enable the
new behavior.

The vhost example has been updated for the new behavior: TSO is applied to
any packet marked LRO.

Fixes: 859b480d5afd ("vhost: add guest offload setting")
Cc: stable@dpdk.org

Signed-off-by: David Marchand <david.marchand@redhat.com>
Reviewed-by: Maxime Coquelin <maxime.coquelin@redhat.com>

-- 
You are receiving this mail because:
You are the assignee for the bug.

^ permalink raw reply	[flat|nested] only message in thread

only message in thread, other threads:[~2021-05-12  3:25 UTC | newest]

Thread overview: (only message) (download: mbox.gz follow: Atom feed
-- links below jump to the message on this page --
2021-05-12  3:25 [dpdk-dev] [Bug 702] [dpdk-21.05] perf_vm2vm_virtio_net_perf/test_vm2vm_split_ring_iperf_with_tso: vm can't forward big packets bugzilla

This is an external index of several public inboxes,
see mirroring instructions on how to clone and mirror
all data and code used by this external index.