Linux CXL
 help / color / mirror / Atom feed
* [PATCH] docs/cxl: Fix some typos
@ 2022-11-07 18:09 Davidlohr Bueso
  2022-11-07 22:16 ` Ira Weiny
  2022-11-07 22:34 ` Alison Schofield
  0 siblings, 2 replies; 3+ messages in thread
From: Davidlohr Bueso @ 2022-11-07 18:09 UTC (permalink / raw)
  To: jonathan.cameron, mst; +Cc: qemu-devel, linux-cxl, dave

Found while reading the doc.

Signed-off-by: Davidlohr Bueso <dave@stgolabs.net>
---
 docs/system/devices/cxl.rst | 12 ++++++------
 1 file changed, 6 insertions(+), 6 deletions(-)

diff --git a/docs/system/devices/cxl.rst b/docs/system/devices/cxl.rst
index abf7c1f24305..891bbd65d9d8 100644
--- a/docs/system/devices/cxl.rst
+++ b/docs/system/devices/cxl.rst
@@ -83,7 +83,7 @@ CXL Fixed Memory Windows (CFMW)
 A CFMW consists of a particular range of Host Physical Address space
 which is routed to particular CXL Host Bridges.  At time of generic
 software initialization it will have a particularly interleaving
-configuration and associated Quality of Serice Throtling Group (QTG).
+configuration and associated Quality of Service Throttling Group (QTG).
 This information is available to system software, when making
 decisions about how to configure interleave across available CXL
 memory devices.  It is provide as CFMW Structures (CFMWS) in
@@ -98,7 +98,7 @@ specification defined register interface called CXL Host Bridge
 Component Registers (CHBCR). The location of this CHBCR MMIO
 space is described to system software via a CXL Host Bridge
 Structure (CHBS) in the CEDT ACPI table.  The actual interfaces
-are identical to those used for other parts of the CXL heirarchy
+are identical to those used for other parts of the CXL hierarchy
 as CXL Component Registers in PCI BARs.
 
 Interfaces provided include:
@@ -111,7 +111,7 @@ Interfaces provided include:
 
 CXL Root Ports (CXL RP)
 ~~~~~~~~~~~~~~~~~~~~~~~
-A CXL Root Port servers te same purpose as a PCIe Root Port.
+A CXL Root Port servers the same purpose as a PCIe Root Port.
 There are a number of CXL specific Designated Vendor Specific
 Extended Capabilities (DVSEC) in PCIe Configuration Space
 and associated component register access via PCI bars.
@@ -143,7 +143,7 @@ CXL Memory Devices - Type 3
 ~~~~~~~~~~~~~~~~~~~~~~~~~~~
 CXL type 3 devices use a PCI class code and are intended to be supported
 by a generic operating system driver. They have HDM decoders
-though in these EP devices, the decoder is reponsible not for
+though in these EP devices, the decoder is responsible not for
 routing but for translation of the incoming host physical address (HPA)
 into a Device Physical Address (DPA).
 
@@ -209,7 +209,7 @@ Notes:
     ranges of the system physical address map.  Each CFMW has
     particular interleave setup across the CXL Host Bridges (HB)
     CFMW0 provides uninterleaved access to HB0, CFW2 provides
-    uninterleaved acess to HB1. CFW1 provides interleaved memory access
+    uninterleaved access to HB1. CFW1 provides interleaved memory access
     across HB0 and HB1.
 
 (2) **Two CXL Host Bridges**. Each of these has 2 CXL Root Ports and
@@ -282,7 +282,7 @@ Example topology involving a switch::
             ---------------------------------------------------
            |    Switch 0  USP as PCI 0d:00.0                   |
            |    USP has HDM decoder which direct traffic to    |
-           |    appropiate downstream port                     |
+           |    appropriate downstream port                    |
            |    Switch BUS appears as 0e                       |
            |x__________________________________________________|
             |                  |               |              |
-- 
2.38.0


^ permalink raw reply related	[flat|nested] 3+ messages in thread

* Re: [PATCH] docs/cxl: Fix some typos
  2022-11-07 18:09 [PATCH] docs/cxl: Fix some typos Davidlohr Bueso
@ 2022-11-07 22:16 ` Ira Weiny
  2022-11-07 22:34 ` Alison Schofield
  1 sibling, 0 replies; 3+ messages in thread
From: Ira Weiny @ 2022-11-07 22:16 UTC (permalink / raw)
  To: Davidlohr Bueso; +Cc: jonathan.cameron, mst, qemu-devel, linux-cxl

On Mon, Nov 07, 2022 at 10:09:23AM -0800, Davidlohr Bueso wrote:
> Found while reading the doc.
> 
> Signed-off-by: Davidlohr Bueso <dave@stgolabs.net>

Reviewed-by: Ira Weiny <ira.weiny@intel.com>

> ---
>  docs/system/devices/cxl.rst | 12 ++++++------
>  1 file changed, 6 insertions(+), 6 deletions(-)
> 
> diff --git a/docs/system/devices/cxl.rst b/docs/system/devices/cxl.rst
> index abf7c1f24305..891bbd65d9d8 100644
> --- a/docs/system/devices/cxl.rst
> +++ b/docs/system/devices/cxl.rst
> @@ -83,7 +83,7 @@ CXL Fixed Memory Windows (CFMW)
>  A CFMW consists of a particular range of Host Physical Address space
>  which is routed to particular CXL Host Bridges.  At time of generic
>  software initialization it will have a particularly interleaving
> -configuration and associated Quality of Serice Throtling Group (QTG).
> +configuration and associated Quality of Service Throttling Group (QTG).
>  This information is available to system software, when making
>  decisions about how to configure interleave across available CXL
>  memory devices.  It is provide as CFMW Structures (CFMWS) in
> @@ -98,7 +98,7 @@ specification defined register interface called CXL Host Bridge
>  Component Registers (CHBCR). The location of this CHBCR MMIO
>  space is described to system software via a CXL Host Bridge
>  Structure (CHBS) in the CEDT ACPI table.  The actual interfaces
> -are identical to those used for other parts of the CXL heirarchy
> +are identical to those used for other parts of the CXL hierarchy
>  as CXL Component Registers in PCI BARs.
>  
>  Interfaces provided include:
> @@ -111,7 +111,7 @@ Interfaces provided include:
>  
>  CXL Root Ports (CXL RP)
>  ~~~~~~~~~~~~~~~~~~~~~~~
> -A CXL Root Port servers te same purpose as a PCIe Root Port.
> +A CXL Root Port servers the same purpose as a PCIe Root Port.
>  There are a number of CXL specific Designated Vendor Specific
>  Extended Capabilities (DVSEC) in PCIe Configuration Space
>  and associated component register access via PCI bars.
> @@ -143,7 +143,7 @@ CXL Memory Devices - Type 3
>  ~~~~~~~~~~~~~~~~~~~~~~~~~~~
>  CXL type 3 devices use a PCI class code and are intended to be supported
>  by a generic operating system driver. They have HDM decoders
> -though in these EP devices, the decoder is reponsible not for
> +though in these EP devices, the decoder is responsible not for
>  routing but for translation of the incoming host physical address (HPA)
>  into a Device Physical Address (DPA).
>  
> @@ -209,7 +209,7 @@ Notes:
>      ranges of the system physical address map.  Each CFMW has
>      particular interleave setup across the CXL Host Bridges (HB)
>      CFMW0 provides uninterleaved access to HB0, CFW2 provides
> -    uninterleaved acess to HB1. CFW1 provides interleaved memory access
> +    uninterleaved access to HB1. CFW1 provides interleaved memory access
>      across HB0 and HB1.
>  
>  (2) **Two CXL Host Bridges**. Each of these has 2 CXL Root Ports and
> @@ -282,7 +282,7 @@ Example topology involving a switch::
>              ---------------------------------------------------
>             |    Switch 0  USP as PCI 0d:00.0                   |
>             |    USP has HDM decoder which direct traffic to    |
> -           |    appropiate downstream port                     |
> +           |    appropriate downstream port                    |
>             |    Switch BUS appears as 0e                       |
>             |x__________________________________________________|
>              |                  |               |              |
> -- 
> 2.38.0
> 

^ permalink raw reply	[flat|nested] 3+ messages in thread

* Re: [PATCH] docs/cxl: Fix some typos
  2022-11-07 18:09 [PATCH] docs/cxl: Fix some typos Davidlohr Bueso
  2022-11-07 22:16 ` Ira Weiny
@ 2022-11-07 22:34 ` Alison Schofield
  1 sibling, 0 replies; 3+ messages in thread
From: Alison Schofield @ 2022-11-07 22:34 UTC (permalink / raw)
  To: Davidlohr Bueso; +Cc: jonathan.cameron, mst, qemu-devel, linux-cxl

On Mon, Nov 07, 2022 at 10:09:23AM -0800, Davidlohr Bueso wrote:
> Found while reading the doc.
> 
> Signed-off-by: Davidlohr Bueso <dave@stgolabs.net>
> ---
>  docs/system/devices/cxl.rst | 12 ++++++------
>  1 file changed, 6 insertions(+), 6 deletions(-)
> 
> diff --git a/docs/system/devices/cxl.rst b/docs/system/devices/cxl.rst
> index abf7c1f24305..891bbd65d9d8 100644
> --- a/docs/system/devices/cxl.rst
> +++ b/docs/system/devices/cxl.rst
> @@ -83,7 +83,7 @@ CXL Fixed Memory Windows (CFMW)
>  A CFMW consists of a particular range of Host Physical Address space
>  which is routed to particular CXL Host Bridges.  At time of generic
to 'a' particular

>  software initialization it will have a particularly interleaving
s/particularly/particular or just remove usage of the entire word
here and above. Not sure that 'particular'  is particularly helpful
here ;)

> -configuration and associated Quality of Serice Throtling Group (QTG).
> +configuration and associated Quality of Service Throttling Group (QTG).
>  This information is available to system software, when making
>  decisions about how to configure interleave across available CXL
>  memory devices.  It is provide as CFMW Structures (CFMWS) in

s/provide/provided


> @@ -98,7 +98,7 @@ specification defined register interface called CXL Host Bridge
>  Component Registers (CHBCR). The location of this CHBCR MMIO
>  space is described to system software via a CXL Host Bridge
>  Structure (CHBS) in the CEDT ACPI table.  The actual interfaces
> -are identical to those used for other parts of the CXL heirarchy
> +are identical to those used for other parts of the CXL hierarchy
>  as CXL Component Registers in PCI BARs.
>  
>  Interfaces provided include:
> @@ -111,7 +111,7 @@ Interfaces provided include:
>  
>  CXL Root Ports (CXL RP)
>  ~~~~~~~~~~~~~~~~~~~~~~~
> -A CXL Root Port servers te same purpose as a PCIe Root Port.
> +A CXL Root Port servers the same purpose as a PCIe Root Port.

s/servers/serves

>  There are a number of CXL specific Designated Vendor Specific
>  Extended Capabilities (DVSEC) in PCIe Configuration Space
>  and associated component register access via PCI bars.
> @@ -143,7 +143,7 @@ CXL Memory Devices - Type 3
>  ~~~~~~~~~~~~~~~~~~~~~~~~~~~
>  CXL type 3 devices use a PCI class code and are intended to be supported
>  by a generic operating system driver. They have HDM decoders
> -though in these EP devices, the decoder is reponsible not for
> +though in these EP devices, the decoder is responsible not for

s/"responsible not"/"not responsible"

>  routing but for translation of the incoming host physical address (HPA)
>  into a Device Physical Address (DPA).
>  
> @@ -209,7 +209,7 @@ Notes:
>      ranges of the system physical address map.  Each CFMW has
>      particular interleave setup across the CXL Host Bridges (HB)
>      CFMW0 provides uninterleaved access to HB0, CFW2 provides
> -    uninterleaved acess to HB1. CFW1 provides interleaved memory access
> +    uninterleaved access to HB1. CFW1 provides interleaved memory access
>      across HB0 and HB1.

s/CFW1/CFMW1  s/CFW2/CFMW2

>  
>  (2) **Two CXL Host Bridges**. Each of these has 2 CXL Root Ports and
> @@ -282,7 +282,7 @@ Example topology involving a switch::
>              ---------------------------------------------------
>             |    Switch 0  USP as PCI 0d:00.0                   |
>             |    USP has HDM decoder which direct traffic to    |
> -           |    appropiate downstream port                     |
> +           |    appropriate downstream port                    |

to 'the' or to 'an' approp...

>             |    Switch BUS appears as 0e                       |
>             |x__________________________________________________|
>              |                  |               |              |

OK - after picking at this a bit, and only picking at the pieces
I see in this diff, I'll suggest a check back through this section
entirely, rather than the piecemeal spelling corrections.

Alison



> -- 
> 2.38.0
> 

^ permalink raw reply	[flat|nested] 3+ messages in thread

end of thread, other threads:[~2022-11-07 22:34 UTC | newest]

Thread overview: 3+ messages (download: mbox.gz follow: Atom feed
-- links below jump to the message on this page --
2022-11-07 18:09 [PATCH] docs/cxl: Fix some typos Davidlohr Bueso
2022-11-07 22:16 ` Ira Weiny
2022-11-07 22:34 ` Alison Schofield

This is a public inbox, see mirroring instructions
for how to clone and mirror all data and code used for this inbox