* [PATCH 2/2] dt-bindings: iio: temperature: add MLX90632 device bindings
@ 2017-11-29 22:08 Crt Mori
[not found] ` <20171129220805.11358-1-cmo-fc6wVz46lShBDgjK7y7TUQ@public.gmane.org>
0 siblings, 1 reply; 2+ messages in thread
From: Crt Mori @ 2017-11-29 22:08 UTC (permalink / raw)
To: Jonathan Cameron
Cc: linux-iio-u79uwXL29TY76Z2rM5mHXA,
devicetree-u79uwXL29TY76Z2rM5mHXA, Crt Mori
Add device tree bindings for MLX90632 IR temperature sensor.
Signed-off-by: Crt Mori <cmo-fc6wVz46lShBDgjK7y7TUQ@public.gmane.org>
---
.../bindings/iio/temperature/mlx90632.txt | 28 ++++++++++++++++++++++
1 file changed, 28 insertions(+)
create mode 100644 Documentation/devicetree/bindings/iio/temperature/mlx90632.txt
diff --git a/Documentation/devicetree/bindings/iio/temperature/mlx90632.txt b/Documentation/devicetree/bindings/iio/temperature/mlx90632.txt
new file mode 100644
index 000000000000..6073a5ccf9a4
--- /dev/null
+++ b/Documentation/devicetree/bindings/iio/temperature/mlx90632.txt
@@ -0,0 +1,28 @@
+* Melexis MLX90632 contactless Infra Red temperature sensor
+
+Link to datasheet: https://www.melexis.com/en/documents/documentation/datasheets/datasheet-mlx90632
+
+There are various applications for the Infra Red contactless temperature sensor
+and MLX90632 is most suitable for consumer applications where measured object
+temperature is in range between -20 to 200 degrees Celsius with relative error
+of measurement below 1 degree Celsius in object temperature range for
+industrial applications. Since it can operate and measure ambient temperature
+in range of -20 to 85 degrees Celsius it is suitable also for outdoor use.
+
+Be aware that electronics surrounding the sensor can increase ambient
+temperature. MLX90632 can be calibrated to reduce the housing effect via
+already existing EEPROM parameters.
+
+Since measured object emissivity effects Infra Red energy emitted, emissivity
+should be set before requesting the object temperature.
+
+Required properties:
+ - compatible: should be "melexis,mlx90632"
+ - reg: the I2C address of the sensor (default 0x3a)
+
+Example:
+
+mlx90632@02 {
+ compatible = "melexis,mlx90632";
+ reg = <0x3a>;
+};
--
2.15.0
^ permalink raw reply related [flat|nested] 2+ messages in thread[parent not found: <20171129220805.11358-1-cmo-fc6wVz46lShBDgjK7y7TUQ@public.gmane.org>]
* Re: [PATCH 2/2] dt-bindings: iio: temperature: add MLX90632 device bindings [not found] ` <20171129220805.11358-1-cmo-fc6wVz46lShBDgjK7y7TUQ@public.gmane.org> @ 2017-12-01 22:18 ` Rob Herring 0 siblings, 0 replies; 2+ messages in thread From: Rob Herring @ 2017-12-01 22:18 UTC (permalink / raw) To: Crt Mori Cc: Jonathan Cameron, linux-iio-u79uwXL29TY76Z2rM5mHXA, devicetree-u79uwXL29TY76Z2rM5mHXA On Wed, Nov 29, 2017 at 11:08:05PM +0100, Crt Mori wrote: > Add device tree bindings for MLX90632 IR temperature sensor. > > Signed-off-by: Crt Mori <cmo-fc6wVz46lShBDgjK7y7TUQ@public.gmane.org> > --- > .../bindings/iio/temperature/mlx90632.txt | 28 ++++++++++++++++++++++ > 1 file changed, 28 insertions(+) > create mode 100644 Documentation/devicetree/bindings/iio/temperature/mlx90632.txt > > diff --git a/Documentation/devicetree/bindings/iio/temperature/mlx90632.txt b/Documentation/devicetree/bindings/iio/temperature/mlx90632.txt > new file mode 100644 > index 000000000000..6073a5ccf9a4 > --- /dev/null > +++ b/Documentation/devicetree/bindings/iio/temperature/mlx90632.txt > @@ -0,0 +1,28 @@ > +* Melexis MLX90632 contactless Infra Red temperature sensor > + > +Link to datasheet: https://www.melexis.com/en/documents/documentation/datasheets/datasheet-mlx90632 > + > +There are various applications for the Infra Red contactless temperature sensor > +and MLX90632 is most suitable for consumer applications where measured object > +temperature is in range between -20 to 200 degrees Celsius with relative error > +of measurement below 1 degree Celsius in object temperature range for > +industrial applications. Since it can operate and measure ambient temperature > +in range of -20 to 85 degrees Celsius it is suitable also for outdoor use. > + > +Be aware that electronics surrounding the sensor can increase ambient > +temperature. MLX90632 can be calibrated to reduce the housing effect via > +already existing EEPROM parameters. > + > +Since measured object emissivity effects Infra Red energy emitted, emissivity > +should be set before requesting the object temperature. > + > +Required properties: > + - compatible: should be "melexis,mlx90632" > + - reg: the I2C address of the sensor (default 0x3a) > + > +Example: > + > +mlx90632@02 { Should be ...@3a With that, Reviewed-by: Rob Herring <robh-DgEjT+Ai2ygdnm+yROfE0A@public.gmane.org> > + compatible = "melexis,mlx90632"; > + reg = <0x3a>; > +}; > -- > 2.15.0 > > -- > To unsubscribe from this list: send the line "unsubscribe devicetree" in > the body of a message to majordomo-u79uwXL29TY76Z2rM5mHXA@public.gmane.org > More majordomo info at http://vger.kernel.org/majordomo-info.html ^ permalink raw reply [flat|nested] 2+ messages in thread
end of thread, other threads:[~2017-12-01 22:18 UTC | newest]
Thread overview: 2+ messages (download: mbox.gz follow: Atom feed
-- links below jump to the message on this page --
2017-11-29 22:08 [PATCH 2/2] dt-bindings: iio: temperature: add MLX90632 device bindings Crt Mori
[not found] ` <20171129220805.11358-1-cmo-fc6wVz46lShBDgjK7y7TUQ@public.gmane.org>
2017-12-01 22:18 ` Rob Herring
This is a public inbox, see mirroring instructions for how to clone and mirror all data and code used for this inbox