* [BUG] iio: imu: inv_icm42600: read temperature, Invalid Argument
@ 2025-07-07 14:42 Sean Nyekjaer
2025-07-07 15:15 ` David Lechner
2025-07-07 18:13 ` Jean-Baptiste Maneyrol
0 siblings, 2 replies; 9+ messages in thread
From: Sean Nyekjaer @ 2025-07-07 14:42 UTC (permalink / raw)
To: Jean-Baptiste Maneyrol, Jonathan Cameron, David Lechner
Cc: linux-iio, Andy Shevchenko
Hi,
I'm having some weird issues with reading the temperature of the icm42605.
Kernel version: 6.16.0-rc5
# cat /sys/bus/iio/devices/iio:device2/name
icm42605-accel
When reading the temperature I get:
# cat /sys/bus/iio/devices/iio:device2/in_temp_raw
cat: read error: Invalid argument
But if I read from the accelerometer first, I will go better:
# cat /sys/bus/iio/devices/iio:device2/in_accel_x_raw
-378
# cat /sys/bus/iio/devices/iio:device2/in_temp_raw
600
Then after "some" time, I re-read the temperature I recieve
"Invalid argument" again.
I have traced the -EINVAL to inv_icm42600_temp_read() because I receive
INV_ICM42600_DATA_INVALID.
Register dump diff:
--- invalid-read
+++ ok-read
@@ -10,14 +10,14 @@
0x1a = 0x00000010
0x1b = 0x00000000
0x1c = 0x00000000
-0x1d = 0x00000080
-0x1e = 0x00000000
-0x1f = 0x00000080
-0x20 = 0x00000000
-0x21 = 0x00000080
-0x22 = 0x00000000
-0x23 = 0x00000080
-0x24 = 0x00000000
+0x1d = 0x00000002
+0x1e = 0x00000038
+0x1f = 0x000000fe
+0x20 = 0x00000085
+0x21 = 0x000000fe
+0x22 = 0x000000df
+0x23 = 0x000000f8
+0x24 = 0x0000003a
0x25 = 0x00000080
0x26 = 0x00000000
0x27 = 0x00000080
@@ -26,7 +26,7 @@
0x2a = 0x00000000
0x2b = 0x00000000
0x2c = 0x00000000
-0x2d = 0x00000000
+0x2d = 0x00000008
0x2e = 0x00000000
0x2f = 0x00000000
0x30 = 0x000000ff
@@ -59,11 +59,11 @@
0x4b = 0x00000000
0x4c = 0x00000032
0x4d = 0x00000099
-0x4e = 0x00000000
+0x4e = 0x00000002
0x4f = 0x00000009
0x50 = 0x00000009
0x51 = 0x00000016
-0x52 = 0x00000000
+0x52 = 0x00000060
0x53 = 0x0000000d
0x54 = 0x00000031
0x55 = 0x00000000
Will the iio core retry a read? If the -EINVAL is returned,
inv_icm42600_accel_read_raw() is call once more.
One more thing...
When I'm removing the module, the kernel prints this:
inv-icm42600-i2c 1-0068: Runtime PM usage count underflow!
I will continue investigate this
Br,
Sean
^ permalink raw reply [flat|nested] 9+ messages in thread
* Re: [BUG] iio: imu: inv_icm42600: read temperature, Invalid Argument
2025-07-07 14:42 [BUG] iio: imu: inv_icm42600: read temperature, Invalid Argument Sean Nyekjaer
@ 2025-07-07 15:15 ` David Lechner
2025-07-07 18:13 ` Jean-Baptiste Maneyrol
1 sibling, 0 replies; 9+ messages in thread
From: David Lechner @ 2025-07-07 15:15 UTC (permalink / raw)
To: Sean Nyekjaer, Jean-Baptiste Maneyrol, Jonathan Cameron
Cc: linux-iio, Andy Shevchenko
On 7/7/25 9:42 AM, Sean Nyekjaer wrote:
> Hi,
>
> I'm having some weird issues with reading the temperature of the icm42605.
> Kernel version: 6.16.0-rc5
>
> # cat /sys/bus/iio/devices/iio:device2/name
> icm42605-accel
>
> When reading the temperature I get:
> # cat /sys/bus/iio/devices/iio:device2/in_temp_raw
> cat: read error: Invalid argument
>
> But if I read from the accelerometer first, I will go better:
> # cat /sys/bus/iio/devices/iio:device2/in_accel_x_raw
> -378
> # cat /sys/bus/iio/devices/iio:device2/in_temp_raw
> 600
>
> Then after "some" time, I re-read the temperature I recieve
> "Invalid argument" again.
>
> I have traced the -EINVAL to inv_icm42600_temp_read() because I receive
> INV_ICM42600_DATA_INVALID.
>
...
>
> Will the iio core retry a read? If the -EINVAL is returned,
> inv_icm42600_accel_read_raw() is call once more.
No, the core code won't retry, it just passes the error to
userspace. But it does sound like this driver should do a retry
since the datasheet says:
Invalid Data Generation: FIFO/Sense Registers may contain
invalid data under the following conditions:
...
c) When accel and gyro are enabled with different ODRs.
In this case, the sensor with lower ODR will generate
invalid samples when it has no new data
So it could make sense to fsleep() for one ODR period before
attempting to read to ensure data is available - assuming that
is what is actually happening.
>
> One more thing...
> When I'm removing the module, the kernel prints this:
> inv-icm42600-i2c 1-0068: Runtime PM usage count underflow!
It looks like there is an extra pm_runtime_put() near the
end of inv_icm42600_core_probe().
>
> I will continue investigate this
> Br,
> Sean
^ permalink raw reply [flat|nested] 9+ messages in thread
* Re: [BUG] iio: imu: inv_icm42600: read temperature, Invalid Argument
2025-07-07 14:42 [BUG] iio: imu: inv_icm42600: read temperature, Invalid Argument Sean Nyekjaer
2025-07-07 15:15 ` David Lechner
@ 2025-07-07 18:13 ` Jean-Baptiste Maneyrol
2025-07-08 10:35 ` Jonathan Cameron
1 sibling, 1 reply; 9+ messages in thread
From: Jean-Baptiste Maneyrol @ 2025-07-07 18:13 UTC (permalink / raw)
To: Sean Nyekjaer, Jonathan Cameron, David Lechner
Cc: linux-iio@vger.kernel.org, Andy Shevchenko
>Hi,
>
>I'm having some weird issues with reading the temperature of the icm42605.
>Kernel version: 6.16.0-rc5
>
># cat /sys/bus/iio/devices/iio:device2/name
>icm42605-accel
>
>When reading the temperature I get:
># cat /sys/bus/iio/devices/iio:device2/in_temp_raw
>cat: read error: Invalid argument
>
>But if I read from the accelerometer first, I will go better:
># cat /sys/bus/iio/devices/iio:device2/in_accel_x_raw
>-378
># cat /sys/bus/iio/devices/iio:device2/in_temp_raw
>600
>
>Then after "some" time, I re-read the temperature I recieve
>"Invalid argument" again.
>
>I have traced the -EINVAL to inv_icm42600_temp_read() because I receive
>INV_ICM42600_DATA_INVALID.
>
>Register dump diff:
>--- invalid-read
>+++ ok-read
>@@ -10,14 +10,14 @@
> 0x1a = 0x00000010
> 0x1b = 0x00000000
> 0x1c = 0x00000000
>-0x1d = 0x00000080
>-0x1e = 0x00000000
>-0x1f = 0x00000080
>-0x20 = 0x00000000
>-0x21 = 0x00000080
>-0x22 = 0x00000000
>-0x23 = 0x00000080
>-0x24 = 0x00000000
>+0x1d = 0x00000002
>+0x1e = 0x00000038
>+0x1f = 0x000000fe
>+0x20 = 0x00000085
>+0x21 = 0x000000fe
>+0x22 = 0x000000df
>+0x23 = 0x000000f8
>+0x24 = 0x0000003a
> 0x25 = 0x00000080
> 0x26 = 0x00000000
> 0x27 = 0x00000080
>@@ -26,7 +26,7 @@
> 0x2a = 0x00000000
> 0x2b = 0x00000000
> 0x2c = 0x00000000
>-0x2d = 0x00000000
>+0x2d = 0x00000008
> 0x2e = 0x00000000
> 0x2f = 0x00000000
> 0x30 = 0x000000ff
>@@ -59,11 +59,11 @@
> 0x4b = 0x00000000
> 0x4c = 0x00000032
> 0x4d = 0x00000099
>-0x4e = 0x00000000
>+0x4e = 0x00000002
> 0x4f = 0x00000009
> 0x50 = 0x00000009
> 0x51 = 0x00000016
>-0x52 = 0x00000000
>+0x52 = 0x00000060
> 0x53 = 0x0000000d
> 0x54 = 0x00000031
> 0x55 = 0x00000000
>
>Will the iio core retry a read? If the -EINVAL is returned,
>inv_icm42600_accel_read_raw() is call once more.
>
>One more thing...
>When I'm removing the module, the kernel prints this:
>inv-icm42600-i2c 1-0068: Runtime PM usage count underflow!
>
>I will continue investigate this
>Br,
>Sean
Hello Sean,
this is expected behavior since the temperature returned is not the external
temperature but the temperature of the mechanical component (MEMS). It will
only work if the chip is on, meaning accelerometer and/or gyroscope is on.
That's why you can get temperature after reading accel data since it is
turning the chip. But after a short while autosuspend is putting the chip
back off and you cannot read temperature anymore.
You need to turn one sensor continuously on with a buffer, and then you can
read temperature all the time since the chip is running.
Temperature data are here only to do temperature compensation of the accel
and gyro data.
Thanks,
JB
^ permalink raw reply [flat|nested] 9+ messages in thread
* Re: [BUG] iio: imu: inv_icm42600: read temperature, Invalid Argument
2025-07-07 18:13 ` Jean-Baptiste Maneyrol
@ 2025-07-08 10:35 ` Jonathan Cameron
2025-07-08 12:21 ` Jean-Baptiste Maneyrol
0 siblings, 1 reply; 9+ messages in thread
From: Jonathan Cameron @ 2025-07-08 10:35 UTC (permalink / raw)
To: Jean-Baptiste Maneyrol
Cc: Sean Nyekjaer, Jonathan Cameron, David Lechner,
linux-iio@vger.kernel.org, Andy Shevchenko
On Mon, 7 Jul 2025 18:13:33 +0000
Jean-Baptiste Maneyrol <Jean-Baptiste.Maneyrol@tdk.com> wrote:
> >Hi,
> >
> >I'm having some weird issues with reading the temperature of the icm42605.
> >Kernel version: 6.16.0-rc5
> >
> ># cat /sys/bus/iio/devices/iio:device2/name
> >icm42605-accel
> >
> >When reading the temperature I get:
> ># cat /sys/bus/iio/devices/iio:device2/in_temp_raw
> >cat: read error: Invalid argument
> >
> >But if I read from the accelerometer first, I will go better:
> ># cat /sys/bus/iio/devices/iio:device2/in_accel_x_raw
> >-378
> ># cat /sys/bus/iio/devices/iio:device2/in_temp_raw
> >600
> >
> >Then after "some" time, I re-read the temperature I recieve
> >"Invalid argument" again.
> >
> >I have traced the -EINVAL to inv_icm42600_temp_read() because I receive
> >INV_ICM42600_DATA_INVALID.
> >
> >Register dump diff:
> >--- invalid-read
> >+++ ok-read
> >@@ -10,14 +10,14 @@
> > 0x1a = 0x00000010
> > 0x1b = 0x00000000
> > 0x1c = 0x00000000
> >-0x1d = 0x00000080
> >-0x1e = 0x00000000
> >-0x1f = 0x00000080
> >-0x20 = 0x00000000
> >-0x21 = 0x00000080
> >-0x22 = 0x00000000
> >-0x23 = 0x00000080
> >-0x24 = 0x00000000
> >+0x1d = 0x00000002
> >+0x1e = 0x00000038
> >+0x1f = 0x000000fe
> >+0x20 = 0x00000085
> >+0x21 = 0x000000fe
> >+0x22 = 0x000000df
> >+0x23 = 0x000000f8
> >+0x24 = 0x0000003a
> > 0x25 = 0x00000080
> > 0x26 = 0x00000000
> > 0x27 = 0x00000080
> >@@ -26,7 +26,7 @@
> > 0x2a = 0x00000000
> > 0x2b = 0x00000000
> > 0x2c = 0x00000000
> >-0x2d = 0x00000000
> >+0x2d = 0x00000008
> > 0x2e = 0x00000000
> > 0x2f = 0x00000000
> > 0x30 = 0x000000ff
> >@@ -59,11 +59,11 @@
> > 0x4b = 0x00000000
> > 0x4c = 0x00000032
> > 0x4d = 0x00000099
> >-0x4e = 0x00000000
> >+0x4e = 0x00000002
> > 0x4f = 0x00000009
> > 0x50 = 0x00000009
> > 0x51 = 0x00000016
> >-0x52 = 0x00000000
> >+0x52 = 0x00000060
> > 0x53 = 0x0000000d
> > 0x54 = 0x00000031
> > 0x55 = 0x00000000
> >
> >Will the iio core retry a read? If the -EINVAL is returned,
> >inv_icm42600_accel_read_raw() is call once more.
> >
> >One more thing...
> >When I'm removing the module, the kernel prints this:
> >inv-icm42600-i2c 1-0068: Runtime PM usage count underflow!
> >
> >I will continue investigate this
> >Br,
> >Sean
>
> Hello Sean,
>
> this is expected behavior since the temperature returned is not the external
> temperature but the temperature of the mechanical component (MEMS). It will
> only work if the chip is on, meaning accelerometer and/or gyroscope is on.
>
> That's why you can get temperature after reading accel data since it is
> turning the chip. But after a short while autosuspend is putting the chip
> back off and you cannot read temperature anymore.
>
> You need to turn one sensor continuously on with a buffer, and then you can
> read temperature all the time since the chip is running.
>
> Temperature data are here only to do temperature compensation of the accel
> and gyro data.
That is rather non-intuitive behavior. Could we make a read of the temperature
channel turn on one of the components? Given expected use case it shouldn't commonly
happen but if not too horrendous to implement it would be better to avoid the error
seen here.
>
> Thanks,
> JB
^ permalink raw reply [flat|nested] 9+ messages in thread
* Re: [BUG] iio: imu: inv_icm42600: read temperature, Invalid Argument
2025-07-08 10:35 ` Jonathan Cameron
@ 2025-07-08 12:21 ` Jean-Baptiste Maneyrol
2025-07-13 13:46 ` Jonathan Cameron
0 siblings, 1 reply; 9+ messages in thread
From: Jean-Baptiste Maneyrol @ 2025-07-08 12:21 UTC (permalink / raw)
To: Jonathan Cameron
Cc: Sean Nyekjaer, Jonathan Cameron, David Lechner,
linux-iio@vger.kernel.org, Andy Shevchenko
>
>________________________________________
>From: Jonathan Cameron <Jonathan.Cameron@huawei.com>
>Sent: Tuesday, July 8, 2025 12:35
>To: Jean-Baptiste Maneyrol <Jean-Baptiste.Maneyrol@tdk.com>
>Cc: Sean Nyekjaer <sean@geanix.com>; Jonathan Cameron <jic23@kernel.org>; David Lechner <dlechner@baylibre.com>; linux-iio@vger.kernel.org <linux-iio@vger.kernel.org>; Andy Shevchenko <andy@kernel.org>
>Subject: Re: [BUG] iio: imu: inv_icm42600: read temperature, Invalid Argument
>
>This Message Is From an External Sender
>This message came from outside your organization.
>
>On Mon, 7 Jul 2025 18:13:33 +0000
>Jean-Baptiste Maneyrol <Jean-Baptiste.Maneyrol@tdk.com> wrote:
>
>> >Hi,
>> >
>> >I'm having some weird issues with reading the temperature of the icm42605.
>> >Kernel version: 6.16.0-rc5
>> >
>> ># cat /sys/bus/iio/devices/iio:device2/name
>> >icm42605-accel
>> >
>> >When reading the temperature I get:
>> ># cat /sys/bus/iio/devices/iio:device2/in_temp_raw
>> >cat: read error: Invalid argument
>> >
>> >But if I read from the accelerometer first, I will go better:
>> ># cat /sys/bus/iio/devices/iio:device2/in_accel_x_raw
>> >-378
>> ># cat /sys/bus/iio/devices/iio:device2/in_temp_raw
>> >600
>> >
>> >Then after "some" time, I re-read the temperature I recieve
>> >"Invalid argument" again.
>> >
>> >I have traced the -EINVAL to inv_icm42600_temp_read() because I receive
>> >INV_ICM42600_DATA_INVALID.
>> >
>> >Register dump diff:
>> >--- invalid-read
>> >+++ ok-read
>> >@@ -10,14 +10,14 @@
>> > 0x1a = 0x00000010
>> > 0x1b = 0x00000000
>> > 0x1c = 0x00000000
>> >-0x1d = 0x00000080
>> >-0x1e = 0x00000000
>> >-0x1f = 0x00000080
>> >-0x20 = 0x00000000
>> >-0x21 = 0x00000080
>> >-0x22 = 0x00000000
>> >-0x23 = 0x00000080
>> >-0x24 = 0x00000000
>> >+0x1d = 0x00000002
>> >+0x1e = 0x00000038
>> >+0x1f = 0x000000fe
>> >+0x20 = 0x00000085
>> >+0x21 = 0x000000fe
>> >+0x22 = 0x000000df
>> >+0x23 = 0x000000f8
>> >+0x24 = 0x0000003a
>> > 0x25 = 0x00000080
>> > 0x26 = 0x00000000
>> > 0x27 = 0x00000080
>> >@@ -26,7 +26,7 @@
>> > 0x2a = 0x00000000
>> > 0x2b = 0x00000000
>> > 0x2c = 0x00000000
>> >-0x2d = 0x00000000
>> >+0x2d = 0x00000008
>> > 0x2e = 0x00000000
>> > 0x2f = 0x00000000
>> > 0x30 = 0x000000ff
>> >@@ -59,11 +59,11 @@
>> > 0x4b = 0x00000000
>> > 0x4c = 0x00000032
>> > 0x4d = 0x00000099
>> >-0x4e = 0x00000000
>> >+0x4e = 0x00000002
>> > 0x4f = 0x00000009
>> > 0x50 = 0x00000009
>> > 0x51 = 0x00000016
>> >-0x52 = 0x00000000
>> >+0x52 = 0x00000060
>> > 0x53 = 0x0000000d
>> > 0x54 = 0x00000031
>> > 0x55 = 0x00000000
>> >
>> >Will the iio core retry a read? If the -EINVAL is returned,
>> >inv_icm42600_accel_read_raw() is call once more.
>> >
>> >One more thing...
>> >When I'm removing the module, the kernel prints this:
>> >inv-icm42600-i2c 1-0068: Runtime PM usage count underflow!
>> >
>> >I will continue investigate this
>> >Br,
>> >Sean
>>
>> Hello Sean,
>>
>> this is expected behavior since the temperature returned is not the external
>> temperature but the temperature of the mechanical component (MEMS). It will
>> only work if the chip is on, meaning accelerometer and/or gyroscope is on.
>>
>> That's why you can get temperature after reading accel data since it is
>> turning the chip. But after a short while autosuspend is putting the chip
>> back off and you cannot read temperature anymore.
>>
>> You need to turn one sensor continuously on with a buffer, and then you can
>> read temperature all the time since the chip is running.
>>
>> Temperature data are here only to do temperature compensation of the accel
>> and gyro data.
>
>That is rather non-intuitive behavior. Could we make a read of the temperature
>channel turn on one of the components? Given expected use case it shouldn't commonly
>happen but if not too horrendous to implement it would be better to avoid the error
>seen here.
Hello Jonathan,
the problem here is which sensor to turn on? Accel or gyro, or accel+gyro?
And the temperature reported will be completely different if it is accel
and/or gyro running, since gyro is heating much more than accel.
This is not a classical temperature sensor, but an internal one for measuring
temperature of the mechanical part while running. The usual use case on our
side is polling the temperature at low frequency (10Hz, 20Hz) while accel
and/or gyro are running to do temperature compensation on the data read.
We generally want to avoid temperature data in the FIFO because reporting
temperature at high frequency is not useful, and it is consuming space in
the FIFO. We prefer to have more space in the FIFO for accel and gyro data
and do polling of temperature.
Temperature reporting while the chip is off makes absolutely no sense that's
why it is not supported by the chip, even if it can be non-intuitive.
Perhaps we can use another error returning code rather than invalid value?
Otherwise, tell me what you think is the best to do.
Thanks,
JB
>
>>
>> Thanks,
>> JB
>
>
^ permalink raw reply [flat|nested] 9+ messages in thread
* Re: [BUG] iio: imu: inv_icm42600: read temperature, Invalid Argument
2025-07-08 12:21 ` Jean-Baptiste Maneyrol
@ 2025-07-13 13:46 ` Jonathan Cameron
2025-07-14 5:29 ` Sean Nyekjaer
0 siblings, 1 reply; 9+ messages in thread
From: Jonathan Cameron @ 2025-07-13 13:46 UTC (permalink / raw)
To: Jean-Baptiste Maneyrol
Cc: Jonathan Cameron, Sean Nyekjaer, David Lechner,
linux-iio@vger.kernel.org, Andy Shevchenko
On Tue, 8 Jul 2025 12:21:39 +0000
Jean-Baptiste Maneyrol <Jean-Baptiste.Maneyrol@tdk.com> wrote:
> >
> >________________________________________
> >From: Jonathan Cameron <Jonathan.Cameron@huawei.com>
> >Sent: Tuesday, July 8, 2025 12:35
> >To: Jean-Baptiste Maneyrol <Jean-Baptiste.Maneyrol@tdk.com>
> >Cc: Sean Nyekjaer <sean@geanix.com>; Jonathan Cameron <jic23@kernel.org>; David Lechner <dlechner@baylibre.com>; linux-iio@vger.kernel.org <linux-iio@vger.kernel.org>; Andy Shevchenko <andy@kernel.org>
> >Subject: Re: [BUG] iio: imu: inv_icm42600: read temperature, Invalid Argument
> >
> >This Message Is From an External Sender
> >This message came from outside your organization.
> >
> >On Mon, 7 Jul 2025 18:13:33 +0000
> >Jean-Baptiste Maneyrol <Jean-Baptiste.Maneyrol@tdk.com> wrote:
> >
> >> >Hi,
> >> >
> >> >I'm having some weird issues with reading the temperature of the icm42605.
> >> >Kernel version: 6.16.0-rc5
> >> >
> >> ># cat /sys/bus/iio/devices/iio:device2/name
> >> >icm42605-accel
> >> >
> >> >When reading the temperature I get:
> >> ># cat /sys/bus/iio/devices/iio:device2/in_temp_raw
> >> >cat: read error: Invalid argument
> >> >
> >> >But if I read from the accelerometer first, I will go better:
> >> ># cat /sys/bus/iio/devices/iio:device2/in_accel_x_raw
> >> >-378
> >> ># cat /sys/bus/iio/devices/iio:device2/in_temp_raw
> >> >600
> >> >
> >> >Then after "some" time, I re-read the temperature I recieve
> >> >"Invalid argument" again.
> >> >
> >> >I have traced the -EINVAL to inv_icm42600_temp_read() because I receive
> >> >INV_ICM42600_DATA_INVALID.
> >> >
> >> >Register dump diff:
> >> >--- invalid-read
> >> >+++ ok-read
> >> >@@ -10,14 +10,14 @@
> >> > 0x1a = 0x00000010
> >> > 0x1b = 0x00000000
> >> > 0x1c = 0x00000000
> >> >-0x1d = 0x00000080
> >> >-0x1e = 0x00000000
> >> >-0x1f = 0x00000080
> >> >-0x20 = 0x00000000
> >> >-0x21 = 0x00000080
> >> >-0x22 = 0x00000000
> >> >-0x23 = 0x00000080
> >> >-0x24 = 0x00000000
> >> >+0x1d = 0x00000002
> >> >+0x1e = 0x00000038
> >> >+0x1f = 0x000000fe
> >> >+0x20 = 0x00000085
> >> >+0x21 = 0x000000fe
> >> >+0x22 = 0x000000df
> >> >+0x23 = 0x000000f8
> >> >+0x24 = 0x0000003a
> >> > 0x25 = 0x00000080
> >> > 0x26 = 0x00000000
> >> > 0x27 = 0x00000080
> >> >@@ -26,7 +26,7 @@
> >> > 0x2a = 0x00000000
> >> > 0x2b = 0x00000000
> >> > 0x2c = 0x00000000
> >> >-0x2d = 0x00000000
> >> >+0x2d = 0x00000008
> >> > 0x2e = 0x00000000
> >> > 0x2f = 0x00000000
> >> > 0x30 = 0x000000ff
> >> >@@ -59,11 +59,11 @@
> >> > 0x4b = 0x00000000
> >> > 0x4c = 0x00000032
> >> > 0x4d = 0x00000099
> >> >-0x4e = 0x00000000
> >> >+0x4e = 0x00000002
> >> > 0x4f = 0x00000009
> >> > 0x50 = 0x00000009
> >> > 0x51 = 0x00000016
> >> >-0x52 = 0x00000000
> >> >+0x52 = 0x00000060
> >> > 0x53 = 0x0000000d
> >> > 0x54 = 0x00000031
> >> > 0x55 = 0x00000000
> >> >
> >> >Will the iio core retry a read? If the -EINVAL is returned,
> >> >inv_icm42600_accel_read_raw() is call once more.
> >> >
> >> >One more thing...
> >> >When I'm removing the module, the kernel prints this:
> >> >inv-icm42600-i2c 1-0068: Runtime PM usage count underflow!
> >> >
> >> >I will continue investigate this
> >> >Br,
> >> >Sean
> >>
> >> Hello Sean,
> >>
> >> this is expected behavior since the temperature returned is not the external
> >> temperature but the temperature of the mechanical component (MEMS). It will
> >> only work if the chip is on, meaning accelerometer and/or gyroscope is on.
> >>
> >> That's why you can get temperature after reading accel data since it is
> >> turning the chip. But after a short while autosuspend is putting the chip
> >> back off and you cannot read temperature anymore.
> >>
> >> You need to turn one sensor continuously on with a buffer, and then you can
> >> read temperature all the time since the chip is running.
> >>
> >> Temperature data are here only to do temperature compensation of the accel
> >> and gyro data.
> >
> >That is rather non-intuitive behavior. Could we make a read of the temperature
> >channel turn on one of the components? Given expected use case it shouldn't commonly
> >happen but if not too horrendous to implement it would be better to avoid the error
> >seen here.
>
> Hello Jonathan,
>
> the problem here is which sensor to turn on? Accel or gyro, or accel+gyro?
> And the temperature reported will be completely different if it is accel
> and/or gyro running, since gyro is heating much more than accel.
>
> This is not a classical temperature sensor, but an internal one for measuring
> temperature of the mechanical part while running. The usual use case on our
> side is polling the temperature at low frequency (10Hz, 20Hz) while accel
> and/or gyro are running to do temperature compensation on the data read.
>
> We generally want to avoid temperature data in the FIFO because reporting
> temperature at high frequency is not useful, and it is consuming space in
> the FIFO. We prefer to have more space in the FIFO for accel and gyro data
> and do polling of temperature.
>
> Temperature reporting while the chip is off makes absolutely no sense that's
> why it is not supported by the chip, even if it can be non-intuitive.
>
> Perhaps we can use another error returning code rather than invalid value?
> Otherwise, tell me what you think is the best to do.
Maybe indicate it is a temporary situation that userspace can resolve
by reporting -EBUSY? I'm not sure what the best path forward here is.
Your explanation seems reasonable to me. Sean, do you still believe
we need to make a change here?
Jonathan
>
> Thanks,
> JB
>
> >
> >>
> >> Thanks,
> >> JB
> >
> >
^ permalink raw reply [flat|nested] 9+ messages in thread
* Re: [BUG] iio: imu: inv_icm42600: read temperature, Invalid Argument
2025-07-13 13:46 ` Jonathan Cameron
@ 2025-07-14 5:29 ` Sean Nyekjaer
2025-07-27 16:53 ` Jonathan Cameron
0 siblings, 1 reply; 9+ messages in thread
From: Sean Nyekjaer @ 2025-07-14 5:29 UTC (permalink / raw)
To: Jonathan Cameron
Cc: Jean-Baptiste Maneyrol, Jonathan Cameron, David Lechner,
linux-iio@vger.kernel.org, Andy Shevchenko
On Sun, Jul 13, 2025 at 02:46:32PM +0100, Jonathan Cameron wrote:
> On Tue, 8 Jul 2025 12:21:39 +0000
> Jean-Baptiste Maneyrol <Jean-Baptiste.Maneyrol@tdk.com> wrote:
>
> > >
> > >________________________________________
> > >From: Jonathan Cameron <Jonathan.Cameron@huawei.com>
> > >Sent: Tuesday, July 8, 2025 12:35
> > >To: Jean-Baptiste Maneyrol <Jean-Baptiste.Maneyrol@tdk.com>
> > >Cc: Sean Nyekjaer <sean@geanix.com>; Jonathan Cameron <jic23@kernel.org>; David Lechner <dlechner@baylibre.com>; linux-iio@vger.kernel.org <linux-iio@vger.kernel.org>; Andy Shevchenko <andy@kernel.org>
> > >Subject: Re: [BUG] iio: imu: inv_icm42600: read temperature, Invalid Argument
> > >
> > >This Message Is From an External Sender
> > >This message came from outside your organization.
> > >
> > >On Mon, 7 Jul 2025 18:13:33 +0000
> > >Jean-Baptiste Maneyrol <Jean-Baptiste.Maneyrol@tdk.com> wrote:
> > >
> > >> >Hi,
> > >> >
> > >> >I'm having some weird issues with reading the temperature of the icm42605.
> > >> >Kernel version: 6.16.0-rc5
> > >> >
> > >> ># cat /sys/bus/iio/devices/iio:device2/name
> > >> >icm42605-accel
> > >> >
> > >> >When reading the temperature I get:
> > >> ># cat /sys/bus/iio/devices/iio:device2/in_temp_raw
> > >> >cat: read error: Invalid argument
> > >> >
> > >> >But if I read from the accelerometer first, I will go better:
> > >> ># cat /sys/bus/iio/devices/iio:device2/in_accel_x_raw
> > >> >-378
> > >> ># cat /sys/bus/iio/devices/iio:device2/in_temp_raw
> > >> >600
> > >> >
> > >> >Then after "some" time, I re-read the temperature I recieve
> > >> >"Invalid argument" again.
> > >> >
> > >> >I have traced the -EINVAL to inv_icm42600_temp_read() because I receive
> > >> >INV_ICM42600_DATA_INVALID.
> > >> >
> > >> >Register dump diff:
> > >> >--- invalid-read
> > >> >+++ ok-read
> > >> >@@ -10,14 +10,14 @@
> > >> > 0x1a = 0x00000010
> > >> > 0x1b = 0x00000000
> > >> > 0x1c = 0x00000000
> > >> >-0x1d = 0x00000080
> > >> >-0x1e = 0x00000000
> > >> >-0x1f = 0x00000080
> > >> >-0x20 = 0x00000000
> > >> >-0x21 = 0x00000080
> > >> >-0x22 = 0x00000000
> > >> >-0x23 = 0x00000080
> > >> >-0x24 = 0x00000000
> > >> >+0x1d = 0x00000002
> > >> >+0x1e = 0x00000038
> > >> >+0x1f = 0x000000fe
> > >> >+0x20 = 0x00000085
> > >> >+0x21 = 0x000000fe
> > >> >+0x22 = 0x000000df
> > >> >+0x23 = 0x000000f8
> > >> >+0x24 = 0x0000003a
> > >> > 0x25 = 0x00000080
> > >> > 0x26 = 0x00000000
> > >> > 0x27 = 0x00000080
> > >> >@@ -26,7 +26,7 @@
> > >> > 0x2a = 0x00000000
> > >> > 0x2b = 0x00000000
> > >> > 0x2c = 0x00000000
> > >> >-0x2d = 0x00000000
> > >> >+0x2d = 0x00000008
> > >> > 0x2e = 0x00000000
> > >> > 0x2f = 0x00000000
> > >> > 0x30 = 0x000000ff
> > >> >@@ -59,11 +59,11 @@
> > >> > 0x4b = 0x00000000
> > >> > 0x4c = 0x00000032
> > >> > 0x4d = 0x00000099
> > >> >-0x4e = 0x00000000
> > >> >+0x4e = 0x00000002
> > >> > 0x4f = 0x00000009
> > >> > 0x50 = 0x00000009
> > >> > 0x51 = 0x00000016
> > >> >-0x52 = 0x00000000
> > >> >+0x52 = 0x00000060
> > >> > 0x53 = 0x0000000d
> > >> > 0x54 = 0x00000031
> > >> > 0x55 = 0x00000000
> > >> >
> > >> >Will the iio core retry a read? If the -EINVAL is returned,
> > >> >inv_icm42600_accel_read_raw() is call once more.
> > >> >
> > >> >One more thing...
> > >> >When I'm removing the module, the kernel prints this:
> > >> >inv-icm42600-i2c 1-0068: Runtime PM usage count underflow!
> > >> >
> > >> >I will continue investigate this
> > >> >Br,
> > >> >Sean
> > >>
> > >> Hello Sean,
> > >>
> > >> this is expected behavior since the temperature returned is not the external
> > >> temperature but the temperature of the mechanical component (MEMS). It will
> > >> only work if the chip is on, meaning accelerometer and/or gyroscope is on.
> > >>
> > >> That's why you can get temperature after reading accel data since it is
> > >> turning the chip. But after a short while autosuspend is putting the chip
> > >> back off and you cannot read temperature anymore.
> > >>
> > >> You need to turn one sensor continuously on with a buffer, and then you can
> > >> read temperature all the time since the chip is running.
> > >>
> > >> Temperature data are here only to do temperature compensation of the accel
> > >> and gyro data.
> > >
> > >That is rather non-intuitive behavior. Could we make a read of the temperature
> > >channel turn on one of the components? Given expected use case it shouldn't commonly
> > >happen but if not too horrendous to implement it would be better to avoid the error
> > >seen here.
> >
> > Hello Jonathan,
> >
> > the problem here is which sensor to turn on? Accel or gyro, or accel+gyro?
> > And the temperature reported will be completely different if it is accel
> > and/or gyro running, since gyro is heating much more than accel.
> >
> > This is not a classical temperature sensor, but an internal one for measuring
> > temperature of the mechanical part while running. The usual use case on our
> > side is polling the temperature at low frequency (10Hz, 20Hz) while accel
> > and/or gyro are running to do temperature compensation on the data read.
> >
> > We generally want to avoid temperature data in the FIFO because reporting
> > temperature at high frequency is not useful, and it is consuming space in
> > the FIFO. We prefer to have more space in the FIFO for accel and gyro data
> > and do polling of temperature.
> >
> > Temperature reporting while the chip is off makes absolutely no sense that's
> > why it is not supported by the chip, even if it can be non-intuitive.
> >
> > Perhaps we can use another error returning code rather than invalid value?
> > Otherwise, tell me what you think is the best to do.
>
> Maybe indicate it is a temporary situation that userspace can resolve
> by reporting -EBUSY? I'm not sure what the best path forward here is.
>
> Your explanation seems reasonable to me. Sean, do you still believe
> we need to make a change here?
I think -EBUSY would be better, returning -EINVAL required me to read the driver,
and apply some debug printk's to see where it originated from.
Returning -EBUSY and add a comment about the "issue" in
inv_icm42600_temp_read(), would be a help.
/Sean
>
> Jonathan
>
> >
> > Thanks,
> > JB
> >
> > >
> > >>
> > >> Thanks,
> > >> JB
> > >
> > >
>
^ permalink raw reply [flat|nested] 9+ messages in thread
* Re: [BUG] iio: imu: inv_icm42600: read temperature, Invalid Argument
2025-07-14 5:29 ` Sean Nyekjaer
@ 2025-07-27 16:53 ` Jonathan Cameron
2025-08-08 7:28 ` Jean-Baptiste Maneyrol
0 siblings, 1 reply; 9+ messages in thread
From: Jonathan Cameron @ 2025-07-27 16:53 UTC (permalink / raw)
To: Sean Nyekjaer
Cc: Jean-Baptiste Maneyrol, Jonathan Cameron, David Lechner,
linux-iio@vger.kernel.org, Andy Shevchenko
On Mon, 14 Jul 2025 05:29:00 +0000
Sean Nyekjaer <sean@geanix.com> wrote:
> On Sun, Jul 13, 2025 at 02:46:32PM +0100, Jonathan Cameron wrote:
> > On Tue, 8 Jul 2025 12:21:39 +0000
> > Jean-Baptiste Maneyrol <Jean-Baptiste.Maneyrol@tdk.com> wrote:
> >
> > > >
> > > >________________________________________
> > > >From: Jonathan Cameron <Jonathan.Cameron@huawei.com>
> > > >Sent: Tuesday, July 8, 2025 12:35
> > > >To: Jean-Baptiste Maneyrol <Jean-Baptiste.Maneyrol@tdk.com>
> > > >Cc: Sean Nyekjaer <sean@geanix.com>; Jonathan Cameron <jic23@kernel.org>; David Lechner <dlechner@baylibre.com>; linux-iio@vger.kernel.org <linux-iio@vger.kernel.org>; Andy Shevchenko <andy@kernel.org>
> > > >Subject: Re: [BUG] iio: imu: inv_icm42600: read temperature, Invalid Argument
> > > >
> > > >This Message Is From an External Sender
> > > >This message came from outside your organization.
> > > >
> > > >On Mon, 7 Jul 2025 18:13:33 +0000
> > > >Jean-Baptiste Maneyrol <Jean-Baptiste.Maneyrol@tdk.com> wrote:
> > > >
> > > >> >Hi,
> > > >> >
> > > >> >I'm having some weird issues with reading the temperature of the icm42605.
> > > >> >Kernel version: 6.16.0-rc5
> > > >> >
> > > >> ># cat /sys/bus/iio/devices/iio:device2/name
> > > >> >icm42605-accel
> > > >> >
> > > >> >When reading the temperature I get:
> > > >> ># cat /sys/bus/iio/devices/iio:device2/in_temp_raw
> > > >> >cat: read error: Invalid argument
> > > >> >
> > > >> >But if I read from the accelerometer first, I will go better:
> > > >> ># cat /sys/bus/iio/devices/iio:device2/in_accel_x_raw
> > > >> >-378
> > > >> ># cat /sys/bus/iio/devices/iio:device2/in_temp_raw
> > > >> >600
> > > >> >
> > > >> >Then after "some" time, I re-read the temperature I recieve
> > > >> >"Invalid argument" again.
> > > >> >
> > > >> >I have traced the -EINVAL to inv_icm42600_temp_read() because I receive
> > > >> >INV_ICM42600_DATA_INVALID.
> > > >> >
> > > >> >Register dump diff:
> > > >> >--- invalid-read
> > > >> >+++ ok-read
> > > >> >@@ -10,14 +10,14 @@
> > > >> > 0x1a = 0x00000010
> > > >> > 0x1b = 0x00000000
> > > >> > 0x1c = 0x00000000
> > > >> >-0x1d = 0x00000080
> > > >> >-0x1e = 0x00000000
> > > >> >-0x1f = 0x00000080
> > > >> >-0x20 = 0x00000000
> > > >> >-0x21 = 0x00000080
> > > >> >-0x22 = 0x00000000
> > > >> >-0x23 = 0x00000080
> > > >> >-0x24 = 0x00000000
> > > >> >+0x1d = 0x00000002
> > > >> >+0x1e = 0x00000038
> > > >> >+0x1f = 0x000000fe
> > > >> >+0x20 = 0x00000085
> > > >> >+0x21 = 0x000000fe
> > > >> >+0x22 = 0x000000df
> > > >> >+0x23 = 0x000000f8
> > > >> >+0x24 = 0x0000003a
> > > >> > 0x25 = 0x00000080
> > > >> > 0x26 = 0x00000000
> > > >> > 0x27 = 0x00000080
> > > >> >@@ -26,7 +26,7 @@
> > > >> > 0x2a = 0x00000000
> > > >> > 0x2b = 0x00000000
> > > >> > 0x2c = 0x00000000
> > > >> >-0x2d = 0x00000000
> > > >> >+0x2d = 0x00000008
> > > >> > 0x2e = 0x00000000
> > > >> > 0x2f = 0x00000000
> > > >> > 0x30 = 0x000000ff
> > > >> >@@ -59,11 +59,11 @@
> > > >> > 0x4b = 0x00000000
> > > >> > 0x4c = 0x00000032
> > > >> > 0x4d = 0x00000099
> > > >> >-0x4e = 0x00000000
> > > >> >+0x4e = 0x00000002
> > > >> > 0x4f = 0x00000009
> > > >> > 0x50 = 0x00000009
> > > >> > 0x51 = 0x00000016
> > > >> >-0x52 = 0x00000000
> > > >> >+0x52 = 0x00000060
> > > >> > 0x53 = 0x0000000d
> > > >> > 0x54 = 0x00000031
> > > >> > 0x55 = 0x00000000
> > > >> >
> > > >> >Will the iio core retry a read? If the -EINVAL is returned,
> > > >> >inv_icm42600_accel_read_raw() is call once more.
> > > >> >
> > > >> >One more thing...
> > > >> >When I'm removing the module, the kernel prints this:
> > > >> >inv-icm42600-i2c 1-0068: Runtime PM usage count underflow!
> > > >> >
> > > >> >I will continue investigate this
> > > >> >Br,
> > > >> >Sean
> > > >>
> > > >> Hello Sean,
> > > >>
> > > >> this is expected behavior since the temperature returned is not the external
> > > >> temperature but the temperature of the mechanical component (MEMS). It will
> > > >> only work if the chip is on, meaning accelerometer and/or gyroscope is on.
> > > >>
> > > >> That's why you can get temperature after reading accel data since it is
> > > >> turning the chip. But after a short while autosuspend is putting the chip
> > > >> back off and you cannot read temperature anymore.
> > > >>
> > > >> You need to turn one sensor continuously on with a buffer, and then you can
> > > >> read temperature all the time since the chip is running.
> > > >>
> > > >> Temperature data are here only to do temperature compensation of the accel
> > > >> and gyro data.
> > > >
> > > >That is rather non-intuitive behavior. Could we make a read of the temperature
> > > >channel turn on one of the components? Given expected use case it shouldn't commonly
> > > >happen but if not too horrendous to implement it would be better to avoid the error
> > > >seen here.
> > >
> > > Hello Jonathan,
> > >
> > > the problem here is which sensor to turn on? Accel or gyro, or accel+gyro?
> > > And the temperature reported will be completely different if it is accel
> > > and/or gyro running, since gyro is heating much more than accel.
> > >
> > > This is not a classical temperature sensor, but an internal one for measuring
> > > temperature of the mechanical part while running. The usual use case on our
> > > side is polling the temperature at low frequency (10Hz, 20Hz) while accel
> > > and/or gyro are running to do temperature compensation on the data read.
> > >
> > > We generally want to avoid temperature data in the FIFO because reporting
> > > temperature at high frequency is not useful, and it is consuming space in
> > > the FIFO. We prefer to have more space in the FIFO for accel and gyro data
> > > and do polling of temperature.
> > >
> > > Temperature reporting while the chip is off makes absolutely no sense that's
> > > why it is not supported by the chip, even if it can be non-intuitive.
> > >
> > > Perhaps we can use another error returning code rather than invalid value?
> > > Otherwise, tell me what you think is the best to do.
> >
> > Maybe indicate it is a temporary situation that userspace can resolve
> > by reporting -EBUSY? I'm not sure what the best path forward here is.
> >
> > Your explanation seems reasonable to me. Sean, do you still believe
> > we need to make a change here?
>
> I think -EBUSY would be better, returning -EINVAL required me to read the driver,
> and apply some debug printk's to see where it originated from.
>
> Returning -EBUSY and add a comment about the "issue" in
> inv_icm42600_temp_read(), would be a help.
Anyone want to spin a patch? I'm marking this thread closed in patchwork
in the meantime.
Thanks,
Jonathan
>
> /Sean
>
> >
> > Jonathan
> >
> > >
> > > Thanks,
> > > JB
> > >
> > > >
> > > >>
> > > >> Thanks,
> > > >> JB
> > > >
> > > >
> >
>
^ permalink raw reply [flat|nested] 9+ messages in thread
* Re: [BUG] iio: imu: inv_icm42600: read temperature, Invalid Argument
2025-07-27 16:53 ` Jonathan Cameron
@ 2025-08-08 7:28 ` Jean-Baptiste Maneyrol
0 siblings, 0 replies; 9+ messages in thread
From: Jean-Baptiste Maneyrol @ 2025-08-08 7:28 UTC (permalink / raw)
To: Jonathan Cameron
Cc: Sean Nyekjaer, Jonathan Cameron, David Lechner, linux-iio,
andy@kernel.org
>
>________________________________________
>From: Jonathan Cameron <jic23@kernel.org>
>Sent: Sunday, July 27, 2025 18:53
>To: Sean Nyekjaer <sean@geanix.com>
>Cc: Jean-Baptiste Maneyrol <Jean-Baptiste.Maneyrol@tdk.com>; Jonathan Cameron <Jonathan.Cameron@huawei.com>; David Lechner <dlechner@baylibre.com>; linux-iio@vger.kernel.org <linux-iio@vger.kernel.org>; Andy Shevchenko <andy@kernel.org>
>Subject: Re: [BUG] iio: imu: inv_icm42600: read temperature, Invalid Argument
>
>This Message Is From an External Sender
>This message came from outside your organization.
>
>On Mon, 14 Jul 2025 05:29:00 +0000
>Sean Nyekjaer <sean@geanix.com> wrote:
>
>> On Sun, Jul 13, 2025 at 02:46:32PM +0100, Jonathan Cameron wrote:
>> > On Tue, 8 Jul 2025 12:21:39 +0000
>> > Jean-Baptiste Maneyrol <Jean-Baptiste.Maneyrol@tdk.com> wrote:
>> >
>> > > >
>> > > >________________________________________
>> > > >From: Jonathan Cameron <Jonathan.Cameron@huawei.com>
>> > > >Sent: Tuesday, July 8, 2025 12:35
>> > > >To: Jean-Baptiste Maneyrol <Jean-Baptiste.Maneyrol@tdk.com>
>> > > >Cc: Sean Nyekjaer <sean@geanix.com>; Jonathan Cameron <jic23@kernel.org>; David Lechner <dlechner@baylibre.com>; linux-iio@vger.kernel.org <linux-iio@vger.kernel.org>; Andy Shevchenko <andy@kernel.org>
>> > > >Subject: Re: [BUG] iio: imu: inv_icm42600: read temperature, Invalid Argument
>> > > >
>> > > >This Message Is From an External Sender
>> > > >This message came from outside your organization.
>> > > >
>> > > >On Mon, 7 Jul 2025 18:13:33 +0000
>> > > >Jean-Baptiste Maneyrol <Jean-Baptiste.Maneyrol@tdk.com> wrote:
>> > > >
>> > > >> >Hi,
>> > > >> >
>> > > >> >I'm having some weird issues with reading the temperature of the icm42605.
>> > > >> >Kernel version: 6.16.0-rc5
>> > > >> >
>> > > >> ># cat /sys/bus/iio/devices/iio:device2/name
>> > > >> >icm42605-accel
>> > > >> >
>> > > >> >When reading the temperature I get:
>> > > >> ># cat /sys/bus/iio/devices/iio:device2/in_temp_raw
>> > > >> >cat: read error: Invalid argument
>> > > >> >
>> > > >> >But if I read from the accelerometer first, I will go better:
>> > > >> ># cat /sys/bus/iio/devices/iio:device2/in_accel_x_raw
>> > > >> >-378
>> > > >> ># cat /sys/bus/iio/devices/iio:device2/in_temp_raw
>> > > >> >600
>> > > >> >
>> > > >> >Then after "some" time, I re-read the temperature I recieve
>> > > >> >"Invalid argument" again.
>> > > >> >
>> > > >> >I have traced the -EINVAL to inv_icm42600_temp_read() because I receive
>> > > >> >INV_ICM42600_DATA_INVALID.
>> > > >> >
>> > > >> >Register dump diff:
>> > > >> >--- invalid-read
>> > > >> >+++ ok-read
>> > > >> >@@ -10,14 +10,14 @@
>> > > >> > 0x1a = 0x00000010
>> > > >> > 0x1b = 0x00000000
>> > > >> > 0x1c = 0x00000000
>> > > >> >-0x1d = 0x00000080
>> > > >> >-0x1e = 0x00000000
>> > > >> >-0x1f = 0x00000080
>> > > >> >-0x20 = 0x00000000
>> > > >> >-0x21 = 0x00000080
>> > > >> >-0x22 = 0x00000000
>> > > >> >-0x23 = 0x00000080
>> > > >> >-0x24 = 0x00000000
>> > > >> >+0x1d = 0x00000002
>> > > >> >+0x1e = 0x00000038
>> > > >> >+0x1f = 0x000000fe
>> > > >> >+0x20 = 0x00000085
>> > > >> >+0x21 = 0x000000fe
>> > > >> >+0x22 = 0x000000df
>> > > >> >+0x23 = 0x000000f8
>> > > >> >+0x24 = 0x0000003a
>> > > >> > 0x25 = 0x00000080
>> > > >> > 0x26 = 0x00000000
>> > > >> > 0x27 = 0x00000080
>> > > >> >@@ -26,7 +26,7 @@
>> > > >> > 0x2a = 0x00000000
>> > > >> > 0x2b = 0x00000000
>> > > >> > 0x2c = 0x00000000
>> > > >> >-0x2d = 0x00000000
>> > > >> >+0x2d = 0x00000008
>> > > >> > 0x2e = 0x00000000
>> > > >> > 0x2f = 0x00000000
>> > > >> > 0x30 = 0x000000ff
>> > > >> >@@ -59,11 +59,11 @@
>> > > >> > 0x4b = 0x00000000
>> > > >> > 0x4c = 0x00000032
>> > > >> > 0x4d = 0x00000099
>> > > >> >-0x4e = 0x00000000
>> > > >> >+0x4e = 0x00000002
>> > > >> > 0x4f = 0x00000009
>> > > >> > 0x50 = 0x00000009
>> > > >> > 0x51 = 0x00000016
>> > > >> >-0x52 = 0x00000000
>> > > >> >+0x52 = 0x00000060
>> > > >> > 0x53 = 0x0000000d
>> > > >> > 0x54 = 0x00000031
>> > > >> > 0x55 = 0x00000000
>> > > >> >
>> > > >> >Will the iio core retry a read? If the -EINVAL is returned,
>> > > >> >inv_icm42600_accel_read_raw() is call once more.
>> > > >> >
>> > > >> >One more thing...
>> > > >> >When I'm removing the module, the kernel prints this:
>> > > >> >inv-icm42600-i2c 1-0068: Runtime PM usage count underflow!
>> > > >> >
>> > > >> >I will continue investigate this
>> > > >> >Br,
>> > > >> >Sean
>> > > >>
>> > > >> Hello Sean,
>> > > >>
>> > > >> this is expected behavior since the temperature returned is not the external
>> > > >> temperature but the temperature of the mechanical component (MEMS). It will
>> > > >> only work if the chip is on, meaning accelerometer and/or gyroscope is on.
>> > > >>
>> > > >> That's why you can get temperature after reading accel data since it is
>> > > >> turning the chip. But after a short while autosuspend is putting the chip
>> > > >> back off and you cannot read temperature anymore.
>> > > >>
>> > > >> You need to turn one sensor continuously on with a buffer, and then you can
>> > > >> read temperature all the time since the chip is running.
>> > > >>
>> > > >> Temperature data are here only to do temperature compensation of the accel
>> > > >> and gyro data.
>> > > >
>> > > >That is rather non-intuitive behavior. Could we make a read of the temperature
>> > > >channel turn on one of the components? Given expected use case it shouldn't commonly
>> > > >happen but if not too horrendous to implement it would be better to avoid the error
>> > > >seen here.
>> > >
>> > > Hello Jonathan,
>> > >
>> > > the problem here is which sensor to turn on? Accel or gyro, or accel+gyro?
>> > > And the temperature reported will be completely different if it is accel
>> > > and/or gyro running, since gyro is heating much more than accel.
>> > >
>> > > This is not a classical temperature sensor, but an internal one for measuring
>> > > temperature of the mechanical part while running. The usual use case on our
>> > > side is polling the temperature at low frequency (10Hz, 20Hz) while accel
>> > > and/or gyro are running to do temperature compensation on the data read.
>> > >
>> > > We generally want to avoid temperature data in the FIFO because reporting
>> > > temperature at high frequency is not useful, and it is consuming space in
>> > > the FIFO. We prefer to have more space in the FIFO for accel and gyro data
>> > > and do polling of temperature.
>> > >
>> > > Temperature reporting while the chip is off makes absolutely no sense that's
>> > > why it is not supported by the chip, even if it can be non-intuitive.
>> > >
>> > > Perhaps we can use another error returning code rather than invalid value?
>> > > Otherwise, tell me what you think is the best to do.
>> >
>> > Maybe indicate it is a temporary situation that userspace can resolve
>> > by reporting -EBUSY? I'm not sure what the best path forward here is.
>> >
>> > Your explanation seems reasonable to me. Sean, do you still believe
>> > we need to make a change here?
>>
>> I think -EBUSY would be better, returning -EINVAL required me to read the driver,
>> and apply some debug printk's to see where it originated from.
>>
>> Returning -EBUSY and add a comment about the "issue" in
>> inv_icm42600_temp_read(), would be a help.
>
>Anyone want to spin a patch? I'm marking this thread closed in patchwork
>in the meantime.
>
>Thanks,
>
>Jonathan
Hello Jonathan,
I will send a patch to change the error code to EBUSY with a Fixes tag for backporting to stable.
Thanks,
JB
>
>>
>> /Sean
>>
>> >
>> > Jonathan
>> >
>> > >
>> > > Thanks,
>> > > JB
>> > >
>> > > >
>> > > >>
>> > > >> Thanks,
>> > > >> JB
>> > > >
>> > > >
>> >
>>
>
>
^ permalink raw reply [flat|nested] 9+ messages in thread
end of thread, other threads:[~2025-08-08 8:59 UTC | newest]
Thread overview: 9+ messages (download: mbox.gz follow: Atom feed
-- links below jump to the message on this page --
2025-07-07 14:42 [BUG] iio: imu: inv_icm42600: read temperature, Invalid Argument Sean Nyekjaer
2025-07-07 15:15 ` David Lechner
2025-07-07 18:13 ` Jean-Baptiste Maneyrol
2025-07-08 10:35 ` Jonathan Cameron
2025-07-08 12:21 ` Jean-Baptiste Maneyrol
2025-07-13 13:46 ` Jonathan Cameron
2025-07-14 5:29 ` Sean Nyekjaer
2025-07-27 16:53 ` Jonathan Cameron
2025-08-08 7:28 ` Jean-Baptiste Maneyrol
This is a public inbox, see mirroring instructions