* ROHM BM1390 support @ 2023-05-30 8:20 Matti Vaittinen 2023-06-04 13:28 ` Jonathan Cameron 0 siblings, 1 reply; 4+ messages in thread From: Matti Vaittinen @ 2023-05-30 8:20 UTC (permalink / raw) To: Jonathan Cameron; +Cc: linux-iio, Mutanen, Mikko Hi dee Ho peeps, Once again I am trying to learn from more experienced sensor folks :) I am currently working (also) on ROHM BM1390 pressure sensor. The sensor can measure pressure ranging 300 - 1300 hPa. Measurement times can be around 20 - 160 mS depending on the amount of samples being averaged. There is also an IIR filter included in sensor with 3 different settings titled as "weak", "middle" and "strong". Unfortunately the exact maths is not explained. Furthermore, the sensor can be configured to store maximum of 4 measured pressure samples in a HW FIFO. The sensor can also measure temperature and error for temperature measurement is told to be +/- 2C when temperature is in a range of 25 C - 85 C. On the other hand, operating temperature for the device is said to be -40 C - 85 C. Now, the temperature measurements are not stored in a FIFO. Here comes my question - what do you see as the typical use-cases for such a sensor? Or, to be more exact, do you think "quick" changes in temperature are expected to be measured with this type of sensor? I am asking this because I would like to support using the hardware FIFO and I am wondering if reading the temperature at FIFO flush and populating also the temperature channel values corresponding to all (up to 4) pressure measurements would be the best approach? Other options is to not support using FIFO when temperature is scanned. I have a gut feeling that the users who measure pressure are often also interested in getting the temperatures. Hence I would like to allow getting both. "Cheating" by using the same temperature value (measured when FIFO is flushed) should be Ok if temperature is not changing rapidly as even with the slowest measurement speed collecting 4 samples should finish in well under a second - and mentioned accuracy for the temperature sensor is such that small temperature changes are probably going unnoticed anyways. Here I would love to have an opinion from more experienced IIO developers/users - and potentially a hint how similar sensors have been handled previously. (I would assume not storing some slowly changing values in a HW FIFO is quite common because HW FIFOs won't come without a cost). Yours, -- Matti Oh, in case someone wants to see the data sheet: https://fscdn.rohm.com/en/products/databook/datasheet/ic/sensor/pressure/bm1390glv-z-e.pdf -- Matti Vaittinen Linux kernel developer at ROHM Semiconductors Oulu Finland ~~ When things go utterly wrong vim users can always type :help! ~~ ^ permalink raw reply [flat|nested] 4+ messages in thread
* Re: ROHM BM1390 support 2023-05-30 8:20 ROHM BM1390 support Matti Vaittinen @ 2023-06-04 13:28 ` Jonathan Cameron 2023-06-05 6:56 ` Matti Vaittinen 0 siblings, 1 reply; 4+ messages in thread From: Jonathan Cameron @ 2023-06-04 13:28 UTC (permalink / raw) To: Matti Vaittinen; +Cc: linux-iio, Mutanen, Mikko On Tue, 30 May 2023 11:20:59 +0300 Matti Vaittinen <mazziesaccount@gmail.com> wrote: > Hi dee Ho peeps, > > Once again I am trying to learn from more experienced sensor folks :) (Someone get Matti some nice simple devices to add support for - he needs a rest!) :) > > I am currently working (also) on ROHM BM1390 pressure sensor. The sensor > can measure pressure ranging 300 - 1300 hPa. Measurement times can be > around 20 - 160 mS depending on the amount of samples being averaged. > There is also an IIR filter included in sensor with 3 different settings > titled as "weak", "middle" and "strong". Unfortunately the exact maths > is not explained. Gah. We all love this sort of dumbing down in datasheets. There is a picture though... Hmm. Anyone remember enough about filter design to tell me if you can go from a 63% point on a step response (in time domain) to a 3DB in frequency? I'd go with probably not but it's been far too many years since I did any of this so I could be wrong. I'd kick this into the long grass - pressure sensors that aren't the type that you connect to a pipe tend to be for measuring slow changes, so I'd just set it to the middle value and not worry about making it configurable. Can revisit later. > Furthermore, the sensor can be configured to store > maximum of 4 measured pressure samples in a HW FIFO. > > The sensor can also measure temperature and error for temperature > measurement is told to be +/- 2C when temperature is in a range of 25 C > - 85 C. On the other hand, operating temperature for the device is said > to be -40 C - 85 C. Helpful to have a sensor with no defined precision in the range in which the device is meant to operate. *sniggers* I wonder if it's a typo as the operating range matches the storage range which is unusual. > > Now, the temperature measurements are not stored in a FIFO. > > Here comes my question - what do you see as the typical use-cases for > such a sensor? Or, to be more exact, do you think "quick" changes in > temperature are expected to be measured with this type of sensor? My understanding of pressure sensors is a bit weak so the following might not be accurate... No. Temp stuff on pressure sensors is normally there for temperature compensation algorithms. > I am > asking this because I would like to support using the hardware FIFO and > I am wondering if reading the temperature at FIFO flush and populating > also the temperature channel values corresponding to all (up to 4) > pressure measurements would be the best approach? > > Other options is to not support using FIFO when temperature is scanned. A third is only let the temperature be read from sysfs. That's fairly common in devices like this where the temp sensor isn't expected to be read as often as the others and maps to what we can actually control. (scan_index == -1) IIRC some of the IMUs do this as again temp not expected to change much, but it if has radically different stable values it will affect precision calibration. > > I have a gut feeling that the users who measure pressure are often also > interested in getting the temperatures. Hence I would like to allow > getting both. "Cheating" by using the same temperature value (measured > when FIFO is flushed) should be Ok if temperature is not changing > rapidly as even with the slowest measurement speed collecting 4 samples > should finish in well under a second - and mentioned accuracy for the > temperature sensor is such that small temperature changes are probably > going unnoticed anyways. Fifo normally only of interest at high rates anyway, not that it makes much practical difference when implementing the driver. > > Here I would love to have an opinion from more experienced IIO > developers/users - and potentially a hint how similar sensors have been > handled previously. (I would assume not storing some slowly changing > values in a HW FIFO is quite common because HW FIFOs won't come without > a cost). I don't really mind if you either go with 1 - fill it copies of same temperature. 2 - only have temp via sysfs (this I know we've done a bunch of times) The mess of switch between fifo and non fifo depending on whether the temp sensor is in the scan strikes me as too fiddly to make sense. Jonathan > > Yours, > -- Matti > > Oh, in case someone wants to see the data sheet: > https://fscdn.rohm.com/en/products/databook/datasheet/ic/sensor/pressure/bm1390glv-z-e.pdf > > ^ permalink raw reply [flat|nested] 4+ messages in thread
* Re: ROHM BM1390 support 2023-06-04 13:28 ` Jonathan Cameron @ 2023-06-05 6:56 ` Matti Vaittinen 2023-06-05 18:56 ` Jonathan Cameron 0 siblings, 1 reply; 4+ messages in thread From: Matti Vaittinen @ 2023-06-05 6:56 UTC (permalink / raw) To: Jonathan Cameron; +Cc: linux-iio, Mutanen, Mikko Hi dee Ho - and a big "Thank you" :) On 6/4/23 16:28, Jonathan Cameron wrote: > On Tue, 30 May 2023 11:20:59 +0300 > Matti Vaittinen <mazziesaccount@gmail.com> wrote: > >> Hi dee Ho peeps, >> >> Once again I am trying to learn from more experienced sensor folks :) > > (Someone get Matti some nice simple devices to add support for - he needs > a rest!) :) I don't really mind technical challenges :) But what I would really like to have in our company - and what I do really appreciate getting from you - is someone who I can discuss with to clarify these things :) >> I am currently working (also) on ROHM BM1390 pressure sensor. The sensor >> can measure pressure ranging 300 - 1300 hPa. Measurement times can be >> around 20 - 160 mS depending on the amount of samples being averaged. >> There is also an IIR filter included in sensor with 3 different settings >> titled as "weak", "middle" and "strong". Unfortunately the exact maths >> is not explained. > > Gah. We all love this sort of dumbing down in datasheets. > There is a picture though... Hmm. Anyone remember enough about filter > design to tell me if you can go from a 63% point on a step response (in time domain) > to a 3DB in frequency? I'd go with probably not but it's been far too many years > since I did any of this so I could be wrong. I haven't been dealing with this type of maths since my university studies - and I think I participated last related courses somewhere around 2003 or so. Whoah - I just realized that's 20 years ago! Where did the time go? I did send a question about 3DB boundary frequencies to the HQ though. I wouldn't bet on it but who knows, maybe I can get the actual filter types and the frequencies from there. > I'd kick this into the long grass - pressure sensors that aren't the type that you > connect to a pipe tend to be for measuring slow changes, so I'd just set it to > the middle value and not worry about making it configurable. I was considering just having the IIR disabled by default, but maybe the "middle" setting would indeed be the best way to go. > Can revisit later. > >> Furthermore, the sensor can be configured to store >> maximum of 4 measured pressure samples in a HW FIFO. >> >> The sensor can also measure temperature and error for temperature >> measurement is told to be +/- 2C when temperature is in a range of 25 C >> - 85 C. On the other hand, operating temperature for the device is said >> to be -40 C - 85 C. > > Helpful to have a sensor with no defined precision in the range > in which the device is meant to operate. *sniggers* > I wonder if it's a typo as the operating range matches the storage range > which is unusual. I am not sure. The data-sheet does specifically mentions that the temperature value is signed. It sounds like the sensor was really designed to be used in negative temperatures (degrees C). But yes, the error limit spec is indeed ... Furthermore, the +/-2 C is (IMO) insane unless it means the error is "systematic" and can be compensated to some extent after calibration. I don't think the +/- 2 means it is "in spec" to have measurements jumping up to 4 C in a range of 25 C - 85 C... Well, this is just my thinking though. >> Now, the temperature measurements are not stored in a FIFO. >> >> Here comes my question - what do you see as the typical use-cases for >> such a sensor? Or, to be more exact, do you think "quick" changes in >> temperature are expected to be measured with this type of sensor? > > My understanding of pressure sensors is a bit weak so the following might > not be accurate... > > No. Temp stuff on pressure sensors is normally there for temperature compensation > algorithms. > >> I am >> asking this because I would like to support using the hardware FIFO and >> I am wondering if reading the temperature at FIFO flush and populating >> also the temperature channel values corresponding to all (up to 4) >> pressure measurements would be the best approach? >> >> Other options is to not support using FIFO when temperature is scanned. > > A third is only let the temperature be read from sysfs. That's fairly common > in devices like this where the temp sensor isn't expected to be read as often > as the others and maps to what we can actually control. (scan_index == -1) I thought of this as well. It however gets somewhat "hairy" to allow direct mode access when buffering is used - and I am not sure how convenient it is for users to stop the pressure measurement when temperature is measured. The problem of allowing buffering pressure values when raw-reading temperature values comes from the fact that: a) start/stop for temp/pressure measurement is common and b) if data-ready IRQ is not used we don't have any information about when the temperature measurement is completed. Finally, c) the sensor must not be accessed when FIFO is read. I guess all of these a), b), and c) could be worked around - but the result might not be completely trivial. Thus, stuffing the temperatures in buffer seem simpler for driver and user - although it does waste some bytes. Well, since the sensor is not _really_ high speed thing the memory consumption should still (probably) stay sane. So, if the use-case is not such that temperature changes several degrees / second - then I think I will just stuff the temperatures in buffer as well. > IIRC some of the IMUs do this as again temp not expected to change much, but > it if has radically different stable values it will affect precision calibration. > >> >> I have a gut feeling that the users who measure pressure are often also >> interested in getting the temperatures. Hence I would like to allow >> getting both. "Cheating" by using the same temperature value (measured >> when FIFO is flushed) should be Ok if temperature is not changing >> rapidly as even with the slowest measurement speed collecting 4 samples >> should finish in well under a second - and mentioned accuracy for the >> temperature sensor is such that small temperature changes are probably >> going unnoticed anyways. > > Fifo normally only of interest at high rates anyway, not that it makes much > practical difference when implementing the driver. > >> >> Here I would love to have an opinion from more experienced IIO >> developers/users - and potentially a hint how similar sensors have been >> handled previously. (I would assume not storing some slowly changing >> values in a HW FIFO is quite common because HW FIFOs won't come without >> a cost). > > I don't really mind if you either go with > 1 - fill it copies of same temperature. > 2 - only have temp via sysfs (this I know we've done a bunch of times) So, I'll start with 1 :) > > The mess of switch between fifo and non fifo depending on whether the > temp sensor is in the scan strikes me as too fiddly to make sense. > Agree! Thanks once again Jonathan, You're really helpful! Yours, -- Matti -- Matti Vaittinen Linux kernel developer at ROHM Semiconductors Oulu Finland ~~ When things go utterly wrong vim users can always type :help! ~~ ^ permalink raw reply [flat|nested] 4+ messages in thread
* Re: ROHM BM1390 support 2023-06-05 6:56 ` Matti Vaittinen @ 2023-06-05 18:56 ` Jonathan Cameron 0 siblings, 0 replies; 4+ messages in thread From: Jonathan Cameron @ 2023-06-05 18:56 UTC (permalink / raw) To: Matti Vaittinen; +Cc: linux-iio, Mutanen, Mikko On Mon, 5 Jun 2023 09:56:36 +0300 Matti Vaittinen <mazziesaccount@gmail.com> wrote: > Hi dee Ho - and a big "Thank you" :) > > On 6/4/23 16:28, Jonathan Cameron wrote: > > On Tue, 30 May 2023 11:20:59 +0300 > > Matti Vaittinen <mazziesaccount@gmail.com> wrote: > > > >> Hi dee Ho peeps, > >> > >> Once again I am trying to learn from more experienced sensor folks :) > > > > (Someone get Matti some nice simple devices to add support for - he needs > > a rest!) :) > > I don't really mind technical challenges :) But what I would really like > to have in our company - and what I do really appreciate getting from > you - is someone who I can discuss with to clarify these things :) > > >> I am currently working (also) on ROHM BM1390 pressure sensor. The sensor > >> can measure pressure ranging 300 - 1300 hPa. Measurement times can be > >> around 20 - 160 mS depending on the amount of samples being averaged. > >> There is also an IIR filter included in sensor with 3 different settings > >> titled as "weak", "middle" and "strong". Unfortunately the exact maths > >> is not explained. > > > > Gah. We all love this sort of dumbing down in datasheets. > > There is a picture though... Hmm. Anyone remember enough about filter > > design to tell me if you can go from a 63% point on a step response (in time domain) > > to a 3DB in frequency? I'd go with probably not but it's been far too many years > > since I did any of this so I could be wrong. > > I haven't been dealing with this type of maths since my university > studies - and I think I participated last related courses somewhere > around 2003 or so. Whoah - I just realized that's 20 years ago! Where > did the time go? I did send a question about 3DB boundary frequencies to > the HQ though. I wouldn't bet on it but who knows, maybe I can get the > actual filter types and the frequencies from there. > > > I'd kick this into the long grass - pressure sensors that aren't the type that you > > connect to a pipe tend to be for measuring slow changes, so I'd just set it to > > the middle value and not worry about making it configurable. > > I was considering just having the IIR disabled by default, but maybe the > "middle" setting would indeed be the best way to go. > > > Can revisit later. > > > >> Furthermore, the sensor can be configured to store > >> maximum of 4 measured pressure samples in a HW FIFO. > >> > >> The sensor can also measure temperature and error for temperature > >> measurement is told to be +/- 2C when temperature is in a range of 25 C > >> - 85 C. On the other hand, operating temperature for the device is said > >> to be -40 C - 85 C. > > > > Helpful to have a sensor with no defined precision in the range > > in which the device is meant to operate. *sniggers* > > I wonder if it's a typo as the operating range matches the storage range > > which is unusual. > > I am not sure. The data-sheet does specifically mentions that the > temperature value is signed. It sounds like the sensor was really > designed to be used in negative temperatures (degrees C). > > But yes, the error limit spec is indeed ... > > Furthermore, the +/-2 C is (IMO) insane unless it means the error is > "systematic" and can be compensated to some extent after calibration. I > don't think the +/- 2 means it is "in spec" to have measurements jumping > up to 4 C in a range of 25 C - 85 C... Well, this is just my thinking > though. If there are any suggested temp compensation algorithms for this sensor you may get an idea of how much it matters. Sometimes the answer is not much at all as the temperature dependence is pretty small so 20 degree changes become significant but not +-5 or so. > > >> Now, the temperature measurements are not stored in a FIFO. > >> > >> Here comes my question - what do you see as the typical use-cases for > >> such a sensor? Or, to be more exact, do you think "quick" changes in > >> temperature are expected to be measured with this type of sensor? > > > > My understanding of pressure sensors is a bit weak so the following might > > not be accurate... > > > > No. Temp stuff on pressure sensors is normally there for temperature compensation > > algorithms. > > > >> I am > >> asking this because I would like to support using the hardware FIFO and > >> I am wondering if reading the temperature at FIFO flush and populating > >> also the temperature channel values corresponding to all (up to 4) > >> pressure measurements would be the best approach? > >> > >> Other options is to not support using FIFO when temperature is scanned. > > > > A third is only let the temperature be read from sysfs. That's fairly common > > in devices like this where the temp sensor isn't expected to be read as often > > as the others and maps to what we can actually control. (scan_index == -1) > > I thought of this as well. It however gets somewhat "hairy" to allow > direct mode access when buffering is used - and I am not sure how > convenient it is for users to stop the pressure measurement when > temperature is measured. Ah. Fair enough - some sensors separate this enough that it's straight register read, so on those this approach ends up easy - not in this case it seems. > > The problem of allowing buffering pressure values when raw-reading > temperature values comes from the fact that: > a) start/stop for temp/pressure measurement is common and > b) if data-ready IRQ is not used we don't have any information about > when the temperature measurement is completed. Finally, > c) the sensor must not be accessed when FIFO is read. I'm guessing the dance of grabbing temperature after fifo watermark events may still cause you some trouble. Will be interesting to see how this works out. > > I guess all of these a), b), and c) could be worked around - but the > result might not be completely trivial. Thus, stuffing the temperatures > in buffer seem simpler for driver and user - although it does waste some > bytes. Well, since the sensor is not _really_ high speed thing the > memory consumption should still (probably) stay sane. So, if the > use-case is not such that temperature changes several degrees / second - > then I think I will just stuff the temperatures in buffer as well. As long as userspace can opt out of capturing it, I'd not worry about the overhead etc. > > > IIRC some of the IMUs do this as again temp not expected to change much, but > > it if has radically different stable values it will affect precision calibration. > > > >> > >> I have a gut feeling that the users who measure pressure are often also > >> interested in getting the temperatures. Hence I would like to allow > >> getting both. "Cheating" by using the same temperature value (measured > >> when FIFO is flushed) should be Ok if temperature is not changing > >> rapidly as even with the slowest measurement speed collecting 4 samples > >> should finish in well under a second - and mentioned accuracy for the > >> temperature sensor is such that small temperature changes are probably > >> going unnoticed anyways. > > > > Fifo normally only of interest at high rates anyway, not that it makes much > > practical difference when implementing the driver. > > > >> > >> Here I would love to have an opinion from more experienced IIO > >> developers/users - and potentially a hint how similar sensors have been > >> handled previously. (I would assume not storing some slowly changing > >> values in a HW FIFO is quite common because HW FIFOs won't come without > >> a cost). > > > > I don't really mind if you either go with > > 1 - fill it copies of same temperature. > > 2 - only have temp via sysfs (this I know we've done a bunch of times) > > So, I'll start with 1 :) > > > > > The mess of switch between fifo and non fifo depending on whether the > > temp sensor is in the scan strikes me as too fiddly to make sense. > > > > Agree! > > Thanks once again Jonathan, You're really helpful! No problem, Jonathan > > Yours, > -- Matti > ^ permalink raw reply [flat|nested] 4+ messages in thread
end of thread, other threads:[~2023-06-05 18:57 UTC | newest] Thread overview: 4+ messages (download: mbox.gz follow: Atom feed -- links below jump to the message on this page -- 2023-05-30 8:20 ROHM BM1390 support Matti Vaittinen 2023-06-04 13:28 ` Jonathan Cameron 2023-06-05 6:56 ` Matti Vaittinen 2023-06-05 18:56 ` Jonathan Cameron
This is a public inbox, see mirroring instructions for how to clone and mirror all data and code used for this inbox