* adt7310 uses two event lines.
@ 2011-07-21 11:08 Jonathan Cameron
  2011-07-21 14:07 ` Michael Hennerich
  0 siblings, 1 reply; 2+ messages in thread
From: Jonathan Cameron @ 2011-07-21 11:08 UTC (permalink / raw)
  To: Hennerich, Michael; +Cc: linux-iio@vger.kernel.org

Michael,

Right now there are bugs galore in the multiple event line code.
I'm intending to rip it out for now so as to keep things simple.
We can merge it back in when we have a use case.

The only multiple line user I know of is the adt7310.  Now there
are all sorts of other issues with this driver anyway and it
probably shouldn't be in IIO at all (just a temperature sensor).

In the meantime I propose just deleting the second interrupt line.

Is that alright with you?

Jonathan