* [PATCH] nvme-cli: show partial results if controller fails during list and list-subsys
@ 2018-04-27 17:27 James Smart
2018-04-27 21:43 ` Keith Busch
0 siblings, 1 reply; 2+ messages in thread
From: James Smart @ 2018-04-27 17:27 UTC (permalink / raw)
For the current versions of "list" and "list-subsys":
If a command to a controller fails, which is possible if the controller
is going through a reconnect, the operation will fail and all results
gathered up to that point is dropped. Thus, the operation shows no
results.
Revise the commands so that they will report an error if one of the
controllers fail, but will now skip over the failing controller and
continue with the next one.
Signed-off-by: James Smart <james.smart at broadcom.com>
---
nvme.c | 72 ++++++++++++++++++++++++++++++++++++++++++------------------------
1 file changed, 46 insertions(+), 26 deletions(-)
diff --git a/nvme.c b/nvme.c
index ac255ba..4b62daf 100644
--- a/nvme.c
+++ b/nvme.c
@@ -1217,12 +1217,19 @@ static int scan_ctrls_filter(const struct dirent *d)
return 0;
}
+static void free_ctrl_list_item(struct ctrl_list_item *ctrls)
+{
+ free(ctrls->name);
+ free(ctrls->transport);
+ free(ctrls->address);
+}
+
int get_nvme_subsystem_info(char *name, char *path,
struct subsys_list_item *item)
{
char ctrl_path[512];
struct dirent **ctrls;
- int n, i, ret = 1;
+ int n, i, ret = 1, ccnt = 0;
item->subsysnqn = get_nvme_subsnqn(path);
if (!item->subsysnqn) {
@@ -1247,24 +1254,31 @@ int get_nvme_subsystem_info(char *name, char *path,
item->nctrls = n;
for (i = 0; i < n; i++) {
- item->ctrls[i].name = strdup(ctrls[i]->d_name);
+ item->ctrls[ccnt].name = strdup(ctrls[i]->d_name);
snprintf(ctrl_path, sizeof(ctrl_path), "%s/%s", path,
- item->ctrls[i].name);
+ item->ctrls[ccnt].name);
- item->ctrls[i].address = get_nvme_ctrl_address(ctrl_path);
- if (!item->ctrls[i].address) {
+ item->ctrls[ccnt].address = get_nvme_ctrl_address(ctrl_path);
+ if (!item->ctrls[ccnt].address) {
fprintf(stderr, "failed to get controller[%d] address.\n", i);
- goto free_ctrls;
+ free_ctrl_list_item(&item->ctrls[ccnt]);
+ continue;
}
- item->ctrls[i].transport = get_nvme_ctrl_transport(ctrl_path);
- if (!item->ctrls[i].transport) {
+ item->ctrls[ccnt].transport =
+ get_nvme_ctrl_transport(ctrl_path);
+ if (!item->ctrls[ccnt].transport) {
fprintf(stderr, "failed to get controller[%d] transport.\n", i);
- goto free_ctrls;
+ free_ctrl_list_item(&item->ctrls[ccnt]);
+ continue;
}
+
+ ccnt++;
}
+ item->nctrls = ccnt;
+
ret = 0;
free_ctrls:
@@ -1306,11 +1320,8 @@ static void free_subsys_list_item(struct subsys_list_item *item)
{
int i;
- for (i = 0; i < item->nctrls; i++) {
- free(item->ctrls[i].name);
- free(item->ctrls[i].transport);
- free(item->ctrls[i].address);
- }
+ for (i = 0; i < item->nctrls; i++)
+ free_ctrl_list_item(&item->ctrls[i]);
free(item->ctrls);
free(item->subsysnqn);
@@ -1333,7 +1344,7 @@ static int list_subsys(int argc, char **argv, struct command *cmd,
char path[310];
struct dirent **subsys;
struct subsys_list_item *slist;
- int fmt, n, i, ret = 0;
+ int fmt, n, i, ret = 0, subcnt = 0;
const char *desc = "Retrieve information for subsystems";
struct config {
char *output_format;
@@ -1372,18 +1383,24 @@ static int list_subsys(int argc, char **argv, struct command *cmd,
for (i = 0; i < n; i++) {
snprintf(path, sizeof(path), "%s%s", subsys_dir,
subsys[i]->d_name);
- ret = get_nvme_subsystem_info(subsys[i]->d_name, path, &slist[i]);
- if (ret)
- goto free_subsys;
+ ret = get_nvme_subsystem_info(subsys[i]->d_name, path,
+ &slist[subcnt]);
+ if (ret) {
+ fprintf(stderr,
+ "%s: failed to get subsystem info: %s\n",
+ path, strerror(errno));
+ free_subsys_list_item(&slist[subcnt]);
+ } else
+ subcnt++;
}
if (fmt == JSON)
- json_print_nvme_subsystem_list(slist, n);
+ json_print_nvme_subsystem_list(slist, subcnt);
else
- show_nvme_subsystem_list(slist, n);
+ show_nvme_subsystem_list(slist, subcnt);
free_subsys:
- free_subsys_list(slist, n);
+ free_subsys_list(slist, subcnt);
for (i = 0; i < n; i++)
free(subsys[i]);
@@ -1442,7 +1459,7 @@ static int list(int argc, char **argv, struct command *cmd, struct plugin *plugi
char path[264];
struct dirent **devices;
struct list_item *list_items;
- unsigned int i, n;
+ unsigned int i, n, list_cnt = 0;
int fmt, ret, fd;
const char *desc = "Retrieve basic information for the given device";
struct config {
@@ -1487,16 +1504,19 @@ static int list(int argc, char **argv, struct command *cmd, struct plugin *plugi
strerror(errno));
return errno;
}
- ret = get_nvme_info(fd, &list_items[i], path);
+ ret = get_nvme_info(fd, &list_items[list_cnt], path);
close(fd);
if (ret)
- return ret;
+ fprintf(stderr, "%s: failed to obtain nvme info: %s\n",
+ path, strerror(errno));
+ else
+ list_cnt++;
}
if (fmt == JSON)
- json_print_list_items(list_items, n);
+ json_print_list_items(list_items, list_cnt);
else
- show_list_items(list_items, n);
+ show_list_items(list_items, list_cnt);
for (i = 0; i < n; i++)
free(devices[i]);
--
2.13.1
^ permalink raw reply related [flat|nested] 2+ messages in thread* [PATCH] nvme-cli: show partial results if controller fails during list and list-subsys
2018-04-27 17:27 [PATCH] nvme-cli: show partial results if controller fails during list and list-subsys James Smart
@ 2018-04-27 21:43 ` Keith Busch
0 siblings, 0 replies; 2+ messages in thread
From: Keith Busch @ 2018-04-27 21:43 UTC (permalink / raw)
On Fri, Apr 27, 2018@10:27:33AM -0700, James Smart wrote:
> For the current versions of "list" and "list-subsys":
> If a command to a controller fails, which is possible if the controller
> is going through a reconnect, the operation will fail and all results
> gathered up to that point is dropped. Thus, the operation shows no
> results.
>
> Revise the commands so that they will report an error if one of the
> controllers fail, but will now skip over the failing controller and
> continue with the next one.
>
> Signed-off-by: James Smart <james.smart at broadcom.com>
Looks good, applied.
^ permalink raw reply [flat|nested] 2+ messages in thread
end of thread, other threads:[~2018-04-27 21:43 UTC | newest]
Thread overview: 2+ messages (download: mbox.gz follow: Atom feed
-- links below jump to the message on this page --
2018-04-27 17:27 [PATCH] nvme-cli: show partial results if controller fails during list and list-subsys James Smart
2018-04-27 21:43 ` Keith Busch
This is a public inbox, see mirroring instructions
for how to clone and mirror all data and code used for this inbox